Dazheng Zhao

Dazheng Zhao

Auto-generated profile, based on publicly available information

Dazheng Zhao

Ningbo Cixi Institute of Biomedical Engineering, Ningbo, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YHYang Hu
Yang Hu
JMJingyan Meng
Jingyan Meng
GLGuoning Li
Guoning Li
DZDazheng Zhao
Dazheng Zhao
GFGuang Feng
Guang Feng
CSChangcheng Shi
Changcheng Shi
Robot-assisted rehabilitation therapy has been proven to effectively improve upper-limb motor function in stroke patients. However, most current rehabilitation robotic controllers will provide too much assistance force and focus only on the patient’s position tracking performance while ignoring the patient’s interactive force situation, resulting in the inability to accurately assess the patient’s true motor intention and difficulty stimulating the patient’s initiative, thus negatively affecting the patient’s rehabilitation outcome. Therefore, this paper proposes a fuzzy adaptive passive (FAP) control strategy based on subjects’ task performance and impulse. To ensure the safety of subjects, a passive controller based on the potential field is designed to guide and assist patients in their movements, and the stability of the controller is demonstrated in a passive formalism. Then, using the subject’s task performance and impulse as evaluation indicators, fuzzy logic rules were designed and used as an evaluation algorithm to quantitively assess the subject’s motor ability and to adaptively modify the stiffness coefficient of the potential field and thus change the magnitude of the assistance force to stimulate the subject’s initiative. Through experiments, this control strategy has been shown to not only improve the subject’s initiative during the training process and ensure their safety during training but also enhance the subject’s motor learning ability.

19 October 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
KWKaikai Wang
Kaikai Wang
BFBaoliang Feng
Baoliang Feng
DZDazheng Zhao
Dazheng Zhao
KXKun Xiao
Kun Xiao
GWGang Wu
Gang Wu
CSChangcheng Shi
Changcheng Shi
Unconstrained vital sign monitoring technology has been a hot topic of research in recent years as people increasingly focus on their health status and sleep quality. Conventional contact electrocardiogram (ECG) measurement technology has difficulties in meeting the application needs of sleep scenarios due to short validity period and low comfort. To handle this problem, ECG measurement using non-contact capacitively coupled sensing technology, which do not require direct skin contact for ECG signal acquisition, could be an alternative. However, this method requires fixing the ECG measurement electrodes in two specific positions, which makes it difficult to meet the needs for body differences and multiple sleep postures. This study presents a non-contact sleep ECG measurement system based on a flexible electrode array, which can acquire ECG signals through pajamas and bed sheets using the principle of capacitive coupling. The experiment results showed that the average signal-to-noise ratio (SNR) of the data measured in the supine and lateral postures of subjects was above 30 dB, and the respiratory waves (RW) with the same frequency as contact ECG measurement system could be extracted. We also used this system to acquire ECG signals from multiple points on the dorsal of four subjects and analyzed their variation patterns, and the experimental results were in high agreement with the ECG potential employment recorded by 32-lead body surface maps. Meanwhile, the T-wave, R-wave, S-wave peaks and the ratio of T and R waves of the collected ECG signals were extracted as features. Based on this, the action classification model was trained using long short-term memory network (LSTM) to classify the postures of four subjects in supine, left lateral and right lateral positions, and the classification accuracies were 95.83%, 98.94%, 98.80% and 98.30%, respectively. Although our prototype system must be further improvement and development, these results provide a strong basis for future realization of electrode array-based ECG signal selection algorithms. The proposed system has great potential value in detecting abnormalities of ECG, heart rate (HR), respiration and other vital indicators during human sleep and realizing personalized medical treatment.

19 July 2023 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
JMJingyan Meng
Jingyan Meng
NLNa Li
Na Li
YHYang Hu
Yang Hu
DZDazheng Zhao
Dazheng Zhao
GLGuoning Li
Guoning Li
CSChangcheng Shi
Changcheng Shi
Visual or haptic feedback based on error modulation has been used to improve the effect of robot-assisted rehabilitation training. However, there are several investigations on the effects of error modulation-based visual and haptic feedback fusion strategies on motor learning and motivation. To observe the influence of different feedback fusion strategies on motor learning and motivation, a parallel controlled study was conducted, dividing 30 healthy subjects into three groups with similar skill levels. The no error modulation group received visual and haptic feedback without error modulation; the visual amplification haptic reduction group received visual error amplification combined with haptic error reduction, and the visual reduction haptic amplification (VRHA) group received visual error reduction combined with haptic error amplification. Each subject implemented a trajectory-tracking task with an upper limb rehabilitation robot. They went through baseline, training, assessment, and generalization tests and completed 340 consecutive tracking movements. To evaluate motor learning and motivation, the average tracking error, the root mean square (RMS) of surface electromyography (sEMG) signals, and the intrinsic motivation inventory scale were all examined. In the assessment tests, the average tracking error was significantly decreased in all three groups. In particular, the VRHA group had a larger reduction in average tracking error in the generalization test, lower RMS of sEMG signals both in the assessment and generalization tests and higher perceived competence in the assessment tests. The VRHA fusion strategy significantly improved the subjects’ motor learning and transfer ability, decreased muscle activation, and increased motor learning motivation. These findings may provide some new insights for multisensory feedback fusion technology in the application of rehabilitation robots.