Power loss and voltage magnitude fluctuations are two major issues in distribution networks that have drawn a lot of attention. Numerous strategies have been put forward to provide remedies to lessen the undesirable effects of these issues. Combining two of these approaches and dealing with them simultaneously to get more effective outcomes is essential. Therefore, this study hybridizes the network reconfiguration and capacitor allocation strategies using a novel dingo optimization algorithm (DOA) to solve the optimization problems. The optimization problems for simultaneous network reconfiguration and capacitor allocations were formulated and solved using a novel DOA. To demonstrate its effectiveness, DOA’s results were contrasted with those of the other optimization techniques. The methodology was validated on the IEEE 33-bus network and implemented in the MATLAB program. The results demonstrated that the best network reconfiguration was accomplished with switches 7, 11, 17, 27, and 34 open, and buses 8, 29, and 30 were the best places for capacitors with ideal sizes of 512, 714, and 495 kVAr, respectively. The voltage profile was significantly improved, and the power losses were significantly decreased. When compared to some of the different methods, DOA came out on top.
1 June 2022 in Bulletin of Electrical Engineering and Informatics
Most Nigerian distribution networks are examined on a single-phase basis, which fails to reflect the network's true features. Using three-phase power flow algorithms, this research explores the implications of variations in conductor sizes and spacing on power losses on a Nigerian network. Modified carson's equations were used to model the distribution lines to determine the network's impedance without presuming transposition of the lines. The conductor sizes and spacing were changed to see how they affected network power losses and how they contributed to the distribution network imbalance. The results showed that changing the conductor sizes of certain of the phases increased real power losses by 55.8 and 5.8%, respectively, in phases A and B. Phase C's was reduced by 13.04%. Furthermore, reactive power losses in phases A and B increased by 3.29 and 8.18%, respectively, whereas reactive losses in phase C dropped by 10.32%. Changing the conductor spacing in phases A, B, and C increased real power losses by 825.8, 136.2, and 13.2%, respectively, and reactive power losses by 72.86, 52.30, and 31.89%. Distribution networks should not be evaluated on a single-phase basis since losses differ in each of the three phases. Conductor size and spacing reductions cause huge losses.