Prafulla Hatte

Prafulla Hatte

Auto-generated profile, based on publicly available information

Prafulla Hatte

School of Mechanical Engineering, MIT Academy of Engineering, Alandi, Pune, 412105, India

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2021 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
PHPrafulla Hatte
Prafulla Hatte
YBYogesh Bhalerao
Yogesh Bhalerao
Ethanol is blended with pure gasoline for use as a fuel in a gasoline engine. It is required to conduct physical tests on engines to observe the engine performance for these fuel blends. However, mathematical equations provide a quick, effective, and accurate alternate for physical tests. It may not be possible to develop the mathematical relations for the specific operating conditions of engine and fuel. It is possible to use dimensional analysis approach to develop mathematical model. Dimensional analysis approach is used in this research work for deriving the mathematical correlations of Indicated Mean Effective Pressure, Brake Power, Indicated Power, and Brake Specific Fuel Consumption as engine performance parameters. Their relations are established with engine speed, load on engine, calorific value of fuel fractions, and clearance volume of engine as independent parameters. Buckingham π theorem is used for formulating the relations having proportionality sign showing the possible relations of each dependent parameter with all four independent parameters. Regression analysis is used for eliminating proportionality signs from the equations developed. Mathematical relations developed by the dimensional analysis are accurate. Root Mean Square errors have noted a minimum of 4.19 for Brake Specific Fuel Consumption and a maximum 8.56 for Brake Power. The average percentage errors are less than 1%.

30 November 2023 in Journal of Thermal Engineering
Verified
Journal Article
Open access
PDF file
DKDarshan Karanje
Darshan Karanje
SPShivroop Patil
Shivroop Patil
SGShivraj Gursal
Shivraj Gursal
PHPrafulla Hatte
Prafulla Hatte
Proper ventilation is a critical consideration for the comfort of hospitalized patients. Dry skin, skin rashes, weariness, poor sleep, and other concerns caused by insufficient ventilation can all be avoided with proper ventilation. Air-Ventilated Air Beds are used to supply air to the major parts of the patient’s body. This air bed is constructed in such a way that air is circulated con-tinually throughout the body of the hospitalized patient. It is especially beneficial for people who are bedridden and need to spend a significant amount of time in bed due to illness. Exces-sive heat generated between the bed and the patient is perhaps the common cause of bedsores. Sweating is the leading cause of bedsores. Air ventilation is included in the system to prevent sweating and reduce the incidences of bedsores. Dual compressors, rubber tubes, flow control valves, and anti-decubitus mattresses are among the components used. The rubber tubes are used to ventilate the space between the body of the patient and the upper surface of the air bed. Above the mattress, the rubber tube mesh is positioned. The air is first compressed in two compressors before passing through the distribution manifold and through the meshing. The tubes are altered by drilling holes at certain intervals. The air from the compressor is circulated through the pipes before passing through the openings in the pipes. The unrestricted passage of compressed air via a capillary tube lowers the temperature of the air. The air exhausted through the capillary tubes maintains the patient’s body temperature stable for a while before lowering it. The air is ventilated throughout the bed in this manner. Bedsore can be avoided by reduction of sweat by using the air in close contact with the patient.

1 October 2025 in Journal of Engineering Education Transformations
Verified
Journal Article
Closed access
PHPrafulla Ratnakar Hatte
Prafulla Ratnakar Hatte
SPSagar Dnyandev Patil
Sagar Dnyandev Patil
AMAbhijit Manikrao Malge
Abhijit Manikrao Malge
SPSandeep Pande
Sandeep Pande
Collaborative learning is an activity where students collaborate in groups with peers. This enhanced learning innovative approach is based on the collaborative learning activity conducted in the classroom for the third-year Mechanical students for the course Quality Management. The students were divided into small groups and for each group separate contents were assigned for learning. The learning resources were searched by the students on the net using mobile phones. All the students in the class were involved in learning. After 45 minutes, each group presented their learning, followed by question-answers. Formative assessment was associated with this learning activity. Collaborative learning helped the students not only learn the contents of the course but also enhance skills like group dynamics, Google searching, effective presentations, writing skills, and oral communication. Overall, the average feedback on the activity was observed to be 8.89 on a scale of 1 to 10.