A normal home environment consists of various wireless technologies, in particular WiFi and ZigBee, which usually operate in the ISM 2.4-GHz band. In addition, some of the home appliances (e.g., a microwave oven) may operate in this crowded ISM band. WiFi-based, ZigBee-based devices and home appliances operating at the same frequency and physical space can cause harmful interference to one another, particularly to ZigBee technology. Therefore, the ZigBee Frequency Agility mechanism is introduced by the ZigBee Alliance to ZigBee networks for resolving such harmful interference. In this paper, we experimentally study the performance of the ZigBee Frequency Agility mechanism using a home area network (HAN) testbed. The measurement results show that this mechanism can effectively overcome interference caused by WiFi-based devices. However, in the extreme case, when all the channels are occupied, the mechanism is not effective as expected. In addition, it is observed that the response time for the ZigBee Frequency Agility mechanism to perform channel switching is depending on packet-error-rate (PER) and send-packet-counter thresholds. Low thresholds can reduce channel-switching time but increases signaling overhead. Thus, in order to obtain optimum performance, self-adaptive PER and send-packet-counter thresholds based on interference level are desired rather than static ones.
1 February 2023 in Bulletin of Electrical Engineering and Informatics
Relay nodes are necessary to maintain scalability and increase longevity as the number of manufacturing industrial sensors grows. In a fixed-budget circumstance, however, the cost of purchasing the bare minimum of relay nodes to connect the network may exceed the budget. Although it is hard to establish a network that connects all sensor nodes, in this case, a network with a high level of connection is still desirable. This paper proposes two metrics for determining the connectedness of a disconnected graph of sensor nodes and determining the optimum deployment method for relay nodes in a network with the highest connectedness while staying within a budget restriction. The metrics are the number of connected graph components and the size of the most significant connected graph component. Prim's algorithm and the approximation minimum spanning tree algorithm are applied to construct a disconnected graph and discover the best relay node placement to solve these two criteria. Compared to the other metrics, simulation findings suggest that prioritizing the most significant connected components in the disconnected graph can yield superior outcomes by deploying the fewest number of relay nodes while retaining the connectedness of the graph.
1 February 2023 in Bulletin of Electrical Engineering and Informatics
Relay node (RN) placement expands the network coverage and capacity and significantly reduces the energy consumption of heterogeneous networks (HetNets). Energy efficiency is the system design parameter in HetNets as it determines network operators' energy consumption and economic value. Relay is one of the energy-saving methods, where it can reduce the transmit power by breaking a long transmission distance into several short transmissions. However, placing an RN without a proper transmission distance may lead to a waste of energy. Thus, investigating an optimum RN placement in HetNets is crucial to ensure energy efficiency and maintain network performance. This paper presents an energy efficiency scheme for the RN based on four commonly used network topologies of indoor HetNets. The minimum energy consumption algorithm is proposed based on a comparison of distance and links of the RN. The results show that the circular network topology is an optimal network model with an efficiency factor increase of 6% that can be used to design the energy efficiency indoor HetNet.
17 September 2023 in Jurnal Teknologi (Sciences & Engineering)
The application of Bluetooth Low Energy (BLE) systems for labour tracking on construction sites is a popular research trend. Strategic system deployment is crucial for ensuring the overall reliability and feasibility of these systems. This study aims to identify the optimal BLE system deployment strategy for tiling work zones in three different renovation sites. The BLE system consists of BLE beacon, BLE gateway, Raspberry Pi (data logger), and MATLAB for data analysis. To ensure optimal placement of the BLE gateway, site visits were conducted to evaluate various conditions, such as power supply availability, signal blockage by structures, and potential disruption to the tiling work. In addition, the beacon transmission (Tx) levels were adjusted to enhance the detection accuracy of the system. The findings show that the optimum beacon Tx powers at sites A, B, and C are -12dBm (86.3% accuracy), -16dBm (94.6% accuracy), and -16dBm (91.1% accuracy), respectively. These findings will be adopted in future research on these sites. The study contributes to the understanding of optimal BLE system deployment strategies in construction sites, which can improve labour tracking accuracy and overall project management.