1 November 2016 in Translational Psychiatry
The emerging concept of psychobiotics—live microorganisms with a potential mental health benefit—represents a novel approach for the management of stress-related conditions. The majority of studies have focused on animal models. Recent preclinical studies have identified the B. longum 1714 strain as a putative psychobiotic with an impact on stress-related behaviors, physiology and cognitive performance. Whether such preclinical effects could be translated to healthy human volunteers remains unknown. We tested whether psychobiotic consumption could affect the stress response, cognition and brain activity patterns. In a within-participants design, healthy volunteers (N=22) completed cognitive assessments, resting electroencephalography and were exposed to a socially evaluated cold pressor test at baseline, post-placebo and post-psychobiotic. Increases in cortisol output and subjective anxiety in response to the socially evaluated cold pressor test were attenuated. Furthermore, daily reported stress was reduced by psychobiotic consumption. We also observed subtle improvements in hippocampus-dependent visuospatial memory performance, as well as enhanced frontal midline electroencephalographic mobility following psychobiotic consumption. These subtle but clear benefits are in line with the predicted impact from preclinical screening platforms. Our results indicate that consumption of B. longum 1714 is associated with reduced stress and improved memory. Further studies are warranted to evaluate the benefits of this putative psychobiotic in relevant stress-related conditions and to unravel the mechanisms underlying such effects.
11 July 2007 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Background: Neonatal seizures are often subclinical, making accurate diagnosis difficult. Objective: To describe the clinical manifestations of electrographic seizures recorded on continuous video-EEG, and to compare this description with the recognition of clinical seizures by experienced neonatal staff. Methods: Term infants, at risk of seizures, were monitored by continuous 12-channel video-EEG from <6 hours of birth for up to 72 hours. All clinical seizures were recorded by experienced neonatal staff on individual seizure charts. Video-EEG recordings were subsequently analysed. The number, duration and clinical expression of electrographic seizures were calculated (in seconds), and compared with the seizures clinically suspected by the neonatal staff. Results: Of 51 infants enrolled, nine had electrographic seizures. A further three had clinically suspected seizures, without associated electrographic abnormality. Of the total 526 electrographic seizures, 179 (34%) had clinical manifestations evident on the simultaneous video recording. The clinical seizure activity corresponded to 18.8% of the total electrographic seizure burden. Overdiagnosis also occurred frequently. Of the 177 clinically suspected seizure episodes documented by staff, 48 (27%) had corresponding electrographic evidence of seizure activity Thus, only 9% (48/526) of electrographic seizures were accompanied by clinical manifestations, which were identified and documented by neonatal staff. Conclusion: Only one-third of neonatal EEG seizures displays clinical signs on simultaneous video recordings. Moreover, two-thirds of these clinical manifestations are unrecognised, or misinterpreted by experienced neonatal staff. In the recognition and management of neonatal seizures clinical diagnosis alone is not enough.
1 March 2017 in Brain, Behavior, and Immunity
1 March 2011 in Clinical Neurophysiology
The study presents a multi-channel patient-independent neonatal seizure detection system based on the Support Vector Machine (SVM) classifier. A machine learning algorithm (SVM) is used as a classifier to discriminate between seizure and non-seizure EEG epochs. Two post-processing steps are proposed to increase both the temporal precision and the robustness of the system. The resulting system is validated on a large clinical dataset of 267 h of EEG data from 17 full-term newborns with seizures. The performance of the system using event-based metrics is reported. The system showed the best up-to-date performance of a neonatal seizure detection system. The system was able to achieve an average good detection rate of ~89% with one false seizure detection per hour, ~96% with two false detections per hour, or ~100% with four false detections per hour. An analysis of errors revealed sources of misclassification in terms of both missed seizures and false detections. The results obtained with the proposed SVM-based seizure detection system allow for its practical application in neonatal intensive care units. The proposed SVM-based seizure detection system can greatly assist clinical staff, in a neonatal intensive care unit, to interpret the EEG. The system allows control of the final decision by choosing different confidence levels which makes it flexible for clinical needs. The obtained results may provide a reference for future seizure detection systems.
1 September 2009 in Pediatrics
OBJECTIVE: We examined the evolution of electroencephalographic (EEG) changes after hypoxic injury. METHODS: Continuous, multichannel, video-EEG was recorded for term infants with hypoxic-ischemic encephalopathy, from <6 hours to 72 hours after delivery. One-hour segments at 6, 12, 24, and 48 hours of age of the EEG were analyzed visually, and neurologic outcome was assessed at 24 months. RESULTS: Forty-four infants completed neurodevelopmental follow-up. Of those, 20 (45%) had abnormal outcomes. The EEG grade assigned correlated significantly with outcome. EEG abnormalities improved with time, with the worst EEG grade seen on the earliest recording in all cases. The best predictive ability was seen at 6 hours of age (area under the receiver operator characteristic curve: 0.958 [95% confidence interval: 0.88–1.04]; P = .000). Normal/mildly abnormal EEG results at 6, 12, or 24 hours had 100% positive predictive values for normal outcomes and negative predictive values of 67% to 76%. By 48 hours, many of the EEG findings had improved significantly. This led to the positive predictive value of abnormal EEG results being greater at 48 hours (93%), with a concurrent negative predictive value of 71%. EEG features that were associated with abnormal outcomes were background amplitude of 30 seconds, electrographic seizures, and absence of sleep-wake cycling at 48 hours. CONCLUSIONS: Early EEG is a reliable predictor of outcome in HIE. A normal or mildly abnormal EEG results within 6 hours after birth were associated with normal neurodevelopmental outcomes at 24 months.
6 September 2016 in Developmental Medicine & Child Neurology
Aim: To examine the relationship between electrographic seizures and long‐term outcome in neonates with hypoxic–ischemic encephalopathy (HIE).Method: Full‐term neonates with HIE born in Cork University Maternity Hospital from 2003 to 2006 (pre‐hypothermia era) and 2009 to 2012 (hypothermia era) were included in this observational study. All had early continuous electroencephalography monitoring. All electrographic seizures were annotated. The total seizure burden and hourly seizure burden were calculated. Outcome (normal/abnormal) was assessed at 24 to 48 months in surviving neonates using either the Bayley Scales of Infant and Toddler Development, Third Edition or the Griffiths Mental Development Scales; a diagnosis of cerebral palsy or epilepsy was also considered an abnormal outcome.Results: Continuous electroencephalography was recorded for a median of 57.1 hours (interquartile range 33.5–80.5h) in 47 neonates (31 males, 16 females); 29 out of 47 (62%) had electrographic seizures and 25 out of 47 (53%) had an abnormal outcome. The presence of seizures per se was not associated with abnormal outcome (p=0.126); however, the odds of an abnormal outcome increased over ninefold (odds ratio [OR] 9.56; 95% confidence interval [95% CI] 2.43–37.67) if a neonate had a total seizure burden of more than 40 minutes (p=0.001), and eightfold (OR: 8.00; 95% CI: 2.06–31.07) if a neonate had a maximum hourly seizure burden of more than 13 minutes per hour (p=0.003). Controlling for electrographic HIE grade or treatment with hypothermia did not change the direction of the relationship between seizure burden and outcome.Interpretation: In HIE, a high electrographic seizure burden is significantly associated with abnormal outcome, independent of HIE severity or treatment with hypothermia.