Tales Santini

Tales Santini

Auto-generated profile, based on publicly available information

Tales Santini

Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SWSossena Wood
Sossena Wood
NKNarayanan Krishnamurthy
Narayanan Krishnamurthy
TSTales Santini
Tales Santini
SRShailesh B Raval
Shailesh B Raval
NFNadim Farhat
Nadim Farhat
TITamer S Ibrahim
Tamer S Ibrahim
The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications. An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application that involves electromagnetic-tissue interactions: MRI (due to it being an available resource). The developed phantom was filled with media possessing electromagnetic constitutive parameters that correspond to biological tissues at ~297 MHz. A preliminary comparison between an in-vivo human volunteer (based on whom the anthropomorphic head phantom was created) and various phantoms types, one being the anthropomorphic heterogeneous head phantom, were performed using a 7 Tesla human MRI scanner. Echo planar imaging was performed and minimal ghosting and fluctuations were observed using the proposed anthropomorphic phantom. The magnetic field distributions (during MRI experiments at 7 Tesla) and the scattering parameter (measured using a network analyzer) were most comparable between the anthropomorphic heterogeneous head phantom and an in-vivo human volunteer. The developed anthropomorphic heterogeneous head phantom can be used as a resource to various researchers in applications that involve electromagnetic-biological tissue interactions such as MRI.

10 January 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NKNarayanan Krishnamurthy
Narayanan Krishnamurthy
TSTales Santini
Tales Santini
SWSossena Wood
Sossena Wood
JKJunghwan Kim
Junghwan Kim
TZTiejun Zhao
Tiejun Zhao
TITamer S. Ibrahim
Tamer S. Ibrahim
A variety of 7 Tesla RF coil systems have been proposed to produce spin excitation (B1+ field) and MR image acquisition. Different groups have attempted to mitigate the challenges at high and ultra-high field MRI by proposing novel hardware and software solutions to obtain uniformly high spin excitation at acceptable RF absorption levels. In this study, we extensively compare the designs of two distributed-circuit based RF coils: the Tic-Tac-Toe (TTT) head coil and TEM head coil on multiple anatomically detailed head models and in-vivo. Bench measurements of s-parameters and experimental B1+ field distribution were obtained in volunteers and compared with numerical simulations. RF absorption, quantified by both average and peak SAR, and B1+ field intensity and homogeneity, calculated/measured in terms of maximum over minimum and coefficient of variation (CV) in the region of interest (ROI), are presented for both coils. A study of the RF consistency of both coils across multiple head models for different RF excitation strategies is also presented.

27 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TSTales Santini
Tales Santini
YZYujuan Zhao
Yujuan Zhao
SWSossena Wood
Sossena Wood
NKNarayanan Krishnamurthy
Narayanan Krishnamurthy
JKJunghwan Kim
Junghwan Kim
TITamer S Ibrahim
Tamer S Ibrahim
Radio-frequency (RF) field inhomogeneities and higher levels of specific absorption rate (SAR) still present great challenges in ultrahigh-field (UHF) MRI. In this study, an in-depth analysis of the eigenmodes of a 20-channel transmit Tic-Tac-Toe (TTT) RF array for 7T neuro MRI is presented. The eigenmodes were calculated for five different Z levels (along the static magnetic field direction) of the coil. Four eigenmodes were obtained for each Z level (composed of 4 excitation ports), and they were named based on the characteristics of their field distributions: quadrature, opposite-phase, anti-quadrature, and zero-phase. Corresponding finite-difference time-domain (FDTD) simulations were performed and experimental B1+ field maps were acquired using a homogeneous spherical phantom and human head (in-vivo). The quadrature mode is the most efficient and it excites the central brain regions; the opposite-phase mode excites the brain peripheral regions; anti-quadrature mode excites the head periphery; and the zero-phase mode excites cerebellum and temporal lobes. Using this RF array, up to five eigenmodes (from five different Z levels) can be simultaneously excited. The superposition of these modes has the potential to produce homogeneous excitation with full brain coverage and low levels of SAR at 7T MRI.

1 November 2014 in American Journal of Infection Control
Verified
Journal Article
Closed access
MFMiguel Almeida O. Filho
Miguel Almeida O. Filho
AMAlexandre R. Marra
Alexandre R. Marra
TMThyago Pereira Magnus
Thyago Pereira Magnus
RRRodrigo Dias Rodrigues
Rodrigo Dias Rodrigues
MPMarcelo Prado
Marcelo Prado
MEMichael B. Edmond
Michael B. Edmond

1 August 2016 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
JKJung-Hwan Kim
Jung-Hwan Kim
NKNarayan Krishnamurthy
Narayan Krishnamurthy
TSTales Santini
Tales Santini
YZYujuan Zhao
Yujuan Zhao
TZTiejun Zhao
Tiejun Zhao
TITamer S. Ibrahim
Tamer S. Ibrahim

29 June 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SRShailesh Raval
Shailesh Raval
CBCynthia A. Britton
Cynthia A. Britton
TZTiejun Zhao
Tiejun Zhao
NKNarayanan Krishnamurthy
Narayanan Krishnamurthy
TSTales Santini
Tales Santini
TITamer S. Ibrahim
Tamer S. Ibrahim
The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity]. A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo steady state [DESS], susceptibility weighted imaging [SWI], time-of-flight [TOF], diffusion tensor imaging [DTI], and diffusion spectrum imaging [DSI] were optimized and incorporated with a radiofrequency [RF] coil system composed of a transverse electromagnetic [TEM] transmit coil combined with an 8-channel receive-only array for 7T upper extremity [UE] imaging. In addition, Siemens optimized protocol/sequences were used on a 3T scanner and the resulting images from T1 VIBE and T2 DESS were compared to that obtained at 7T qualitatively and quantitatively [SWI was only qualitatively compared]. DSI studio was utilized to identify nerves based on analysis of diffusion weighted derived fractional anisotropy images. Images of forearm vasculature were extracted using a paint grow manual segmentation method based on MIPAV [Medical Image Processing, Analysis, and Visualization]. High resolution and high quality signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]—images of the hand, forearm, and elbow were acquired with nearly homogeneous 7T excitation. Measured [performed on the T1 VIBE and T2 DESS sequences] SNR and CNR values were almost doubled at 7T vs. 3T. Cartilage, synovial fluid and tendon structures could be seen with higher clarity in the 7T T1 and T2 weighted images. SWI allowed high resolution and better quality imaging of large and medium sized arteries and veins, capillary networks and arteriovenous anastomoses at 7T when compared to 3T. 7T diffusion weighted sequence [not performed at 3T] demonstrates that the forearm nerves are clearly delineated by fiber tractography. The proper digital palmar arteries and superficial palmar arch could also be clearly visualized using TOF nCE 7T MRI. Ultra-high resolution neurovascular imaging in upper extremities is possible at 7T without use of renal toxic intravenous contrast. 7T MRI can provide superior peripheral nerve [based on fiber anisotropy and diffusion coefficient parameters derived from diffusion tensor/spectrum imaging] and vascular [nCE MRA and vessel segmentation] imaging.