Shao-Yun Hsu

Shao-Yun Hsu

Auto-generated profile, based on publicly available information

Shao-Yun Hsu

School of Biological Sciences, Georgia Institute of Technology, Atlanta, Georgia, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2023 in International Journal of Surgery
Verified
Journal Article
Open access
SHShao-Yun Hsu
Shao-Yun Hsu
LCLi-Wei Chen
Li-Wei Chen
RHRen-Wen Huang
Ren-Wen Huang
TTTzong Yueh Tsai
Tzong Yueh Tsai
SHShao-Yu Hung
Shao-Yu Hung
HKHuang-Kai Kao
Huang-Kai Kao
Background: Free flap monitoring is essential for postmicrosurgical management and outcomes but traditionally relies on human observers; the process is subjective and qualitative and imposes a heavy burden on staffing. To scientifically monitor and quantify the condition of free flaps in a clinical scenario, we developed and validated a successful clinical transitional deep learning (DL) model integrated application. Material and Methods: Patients from a single microsurgical intensive care unit between 1 April 2021 and 31 March 2022, were retrospectively analyzed for DL model development, validation, clinical transition, and quantification of free flap monitoring. An iOS application that predicted the probability of flap congestion based on computer vision was developed. The application calculated probability distribution that indicates the flap congestion risks. Accuracy, discrimination, and calibration tests were assessed for model performance evaluations. Results: From a total of 1761 photographs of 642 patients, 122 patients were included during the clinical application period. Development (photographs =328), external validation (photographs =512), and clinical application (photographs =921) cohorts were assigned to corresponding time periods. The performance measurements of the DL model indicate a 92.2% training and a 92.3% validation accuracy. The discrimination (area under the receiver operating characteristic curve) was 0.99 (95% CI: 0.98–1.0) during internal validation and 0.98 (95% CI: 0.97–0.99) under external validation. Among clinical application periods, the application demonstrates 95.3% accuracy, 95.2% sensitivity, and 95.3% specificity. The probabilities of flap congestion were significantly higher in the congested group than in the normal group (78.3 (17.1)% versus 13.2 (18.1)%; 0.8%; 95% CI, P<0.001). Conclusion: The DL integrated smartphone application can accurately reflect and quantify flap condition; it is a convenient, accurate, and economical device that can improve patient safety and management and assist in monitoring flap physiology.