Christina Ilona Esposito

Christina Ilona Esposito

Auto-generated profile, based on publicly available information

Christina Ilona Esposito

Hospital for Special Surgery, 535 East 70th Street, 10021, New York, NY, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
CEChristina I. Esposito
Christina I. Esposito
BGBrian P. Gladnick
Brian P. Gladnick
YLYuo-Yu Lee
Yuo-Yu Lee
SLStephen Lyman
Stephen Lyman
TWTimothy M. Wright
Timothy M. Wright
DPDouglas E. Padgett
Douglas E. Padgett

1 August 2016 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
CEChristina I. Esposito
Christina I. Esposito
TMTheodore T. Miller
Theodore T. Miller
HKHan Jo Kim
Han Jo Kim
BBBrian T. Barlow
Brian T. Barlow
TWTimothy M. Wright
Timothy M. Wright
DMDavid J. Mayman
David J. Mayman
Roacetabular articular motion in the lumbar-pelvic-femoral complex. Multilevel degenerative disc disease (DDD) may limit spine flexion and therefore increase femoroacetabular flexion in patients having THAs, but this has not been well characterized. Therefore, we measured standing and sitting lumbar-pelvic-femoral alignment in patients with radiographic signs of DDD and in patients with no radiographic signs of spine arthrosis. Questions/purposes We asked: (1) Is there a difference in standing and sitting lumbar-pelvic-femoral alignment before surgery among patients undergoing THA who have no radiographic signs of spine arthrosis compared with those with preexisting lumbar DDD? (2) Do patients with lumbar DDD experience less spine flexion moving from a standing to a sitting position and therefore compensate with more femoroacetabular flexion compared with patients who have no radiographic signs of arthrosis? Methods Three hundred twenty-five patients undergoing primary THA had preoperative low-dose EOS spine-to-ankle lateral radiographs in standing and sitting positions. Eighty-three patients were excluded from this study for scoliosis (39 patients), spondylolysis (15 patients), not having five lumbar vertebrae (7 patients), surgical or disease fusion (11 patients), or poor image quality attributable to high BMI (11 patients). In the remaining 242 of 325 patients (75%), two observers categorized the lumbar spine as either without radiographic arthrosis or having DDD based on defined radiographic criteria. Sacral slope, lumbar lordosis, and proximal femur angles were measured, and these angles were used to calculate lumbar spine flexion and femoroacetabular flexion in standing and sitting positions. Patients were aligned in a standardized sitting position so that their femurs were parallel to the floor to achieve approximately 90° of apparent hip flexion. Results After controlling for age, sex, and BMI, we found patients with DDD spines had a mean of 5° more posterior pelvic tilt (95% CI, −2° to −8° lower sacral slope angles; p < 0.01) and 7° less lumbar lordosis (95% CI, −10° to −3°; p < 0.01) in the standing position compared with patients without radiographic arthrosis. However, in the sitting position, patients with DDD spines had 4° less posterior pelvic tilt (95% CI, 1°-7° higher sacral slope angles; p = 0.02). From standing to sitting position, patients with DDD spines experienced 10° less spine flexion (95% CI, −14° to −7°; p < 0.01) and 10° more femoroacetabular flexion (95% CI, 6° to 14°; p < 0.01). Conclusions Most patients undergoing THA sit in a similar range of pelvic tilt, with a small mean difference in pelvic tilt between patients with DDD spines and those without radiographic arthrosis. However, in general, the mechanism by which patients with DDD of the lumbar spine achieve sitting differs from those without spine arthrosis with less spine flexion and more femoroacetabular flexion. Clinical Relevance When planning THA, it may be important to consider which patients sit with less posterior pelvic tilt and those who rotate their pelvises forward to achieve a sitting position, as both mechanisms will limit or reduce the functional anteversion of the acetabular component in a patient with a THA. Our study provides some additional perspective on normal relationships between pelvic tilt and femoroacetabular flexion, but further research might better characterize this relationship in outliers and the possible implications for posterior instability after THA....

1 February 2018 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
MPMichael Pitta
Michael Pitta
CEChristina I. Esposito
Christina I. Esposito
ZLZhichang Li
Zhichang Li
YLYuo-Yu Lee
Yuo-Yu Lee
TWTimothy M. Wright
Timothy M. Wright
DPDouglas E. Padgett
Douglas E. Padgett

1 March 2015 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
JMJoseph D. Maratt
Joseph D. Maratt
CEChristina I. Esposito
Christina I. Esposito
AMAlexander S. McLawhorn
Alexander S. McLawhorn
SJSeth A. Jerabek
Seth A. Jerabek
DPDouglas E. Padgett
Douglas E. Padgett
DMDavid J. Mayman
David J. Mayman

1 July 2014 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
CEChristina I. Esposito
Christina I. Esposito
TWTimothy M. Wright
Timothy M. Wright
Stuart B GoodmanStuart B Goodman
Stuart B Goodman
DBDaniel J. Berry
Daniel J. Berry
BCBiological The Clinical
Biological The Clinical
Recent studies have attributed adverse local tissue reactions (ALTRs) in patients with total hip arthroplasties (THAs) to tribocorrosion debris generated by modular femoral stems. The presentations of ALTR are diverse, as are the causes of it, and the biological responses can be important reasons for failure after THA. (1) What clinical problems have been reported in patients with modular stems since 1988? (2) What THA design features are associated with tribocorrosion in taper junctions? (3) What are the microscopic and tribological characteristics of the debris produced at the taper junctions? (4) What are the cellular and immunological traits of the biological response to taper tribocorrosion debris? We conducted a systematic review using MEDLINE and EMBASE-cited articles to summarize failure modes associated with modular femoral stems. One hundred sixty-two of 1043 articles reported on the clinical performances or failure modes attributed to modular femoral stems. There were 10 laboratory studies, 26 case reports, 13 Level IV, 94 Level III, 18 Level II, and one Level I of Evidence papers. To address the remaining questions, we did a second review of 524 articles. One hundred twenty-seven articles met the eligibility criteria, including 81 articles on design features related to tribocorrosion, 15 articles on corrosion debris characteristics, and 31 articles on the biological response to tribocorrosion debris. Sixty-eight of 162 studies reported failure attributed to modular femoral stems for one of these four modularity-related failure modes: tribocorrosion-associated ALTR, dissociation of a taper junction, stem fracture, and mismatch of a femoral head taper attached to a stem with a different trunnion size. The remaining 94 studies found no clinical consequences related to the presence of a taper junction. THA component features associated with tribocorrosion included trunnion geometry and large-diameter femoral heads. Solid tribocorrosion debris is primarily chromium-orthophosphate material of variable size and may be more biologically reactive than wear debris. There has been an increase in publications describing ALTR around modular hip prostheses in the last 3 years. Implant design changes, including larger femoral heads and smaller trunnions, have been implicated, but there may also be more recognition of the problem by the orthopaedic community. Analyzing retrieved implants to understand the history of taper-related problems, designing clinically relevant in vitro corrosion tests to test modular junctions, and identifying biomarkers to recognize patients at risk of ALTR should be the focus of ongoing research to help surgeons avoid and detect tribocorrosion-related problems in joint replacements.

1 July 2012 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Closed access
CEC. I. Esposito
C. I. Esposito
ARA. Roques
A. Roques
MTM. A. Tuke
M. A. Tuke
BZB. A. Zicat
B. A. Zicat
WWWilliam Walsh
William Walsh
WWW. K. Walter
W. K. Walter
We analysed 54 alumina ceramic-on-ceramic bearings from total hip replacements retrieved at one centre after a mean duration of 3.5 years (0.2 to 10.6) in situ. These implants were obtained from 54 patients (16 men and 38 women) with a mean age of 67 years (33 to 88) who underwent revision for a variety of reasons. Posterior edge loading was found in the majority of these retrievals (32 out of 54). Anterosuperior edge loading occurred less often but produced a higher rate of wear. Stripe wear on the femoral heads had a median volumetric wear rate of 0.2 mm3/year (0 to 7.2). The wear volume on the femoral heads corresponded to the width of edge wear on the matching liner. Anteversion of the acetabular component was found to be a more important determinant than inclination for wear in ceramic bearings. Posterior edge loading may be considered to be a normal occurrence in ceramic-on-ceramic bearings, with minimal clinical consequences. Edge loading should be defined as either anterosuperior or posterior, as each edge loading mechanism may result in different clinical implications.