13 April 2020 in Digestive Endoscopy
Objectives: Detecting early gastric cancer is difficult, and it may even be overlooked by experienced endoscopists. Recently, artificial intelligence based on deep learning through convolutional neural networks (CNNs) has enabled significant advancements in the field of gastroenterology. However, it remains unclear whether a CNN can outperform endoscopists. In this study, we evaluated whether the performance of a CNN in detecting early gastric cancer is better than that of endoscopists.Methods: The CNN was constructed using 13,584 endoscopic images from 2639 lesions of gastric cancer. Subsequently, its diagnostic ability was compared to that of 67 endoscopists using an independent test dataset (2940 images from 140 cases).Results: The average diagnostic time for analyzing 2940 test endoscopic images by the CNN and endoscopists were 45.5 ± 1.8 s and 173.0 ± 66.0 min, respectively. The sensitivity, specificity, and positive and negative predictive values for the CNN were 58.4%, 87.3%, 26.0%, and 96.5%, respectively. These values for the 67 endoscopists were 31.9%, 97.2%, 46.2%, and 94.9%, respectively. The CNN had a significantly higher sensitivity than the endoscopists (by 26.5%; 95% confidence interval, 14.9–32.5%).Conclusion: The CNN detected more early gastric cancer cases in a shorter time than the endoscopists. The CNN needs further training to achieve higher diagnostic accuracy. However, a diagnostic support tool for gastric cancer using a CNN will be realized in the near future.
4 February 2021 in Endoscopy
Background It is known that an esophagus with multiple Lugol-voiding lesions (LVLs) after iodine staining is high risk for esophageal cancer; however, it is preferable to identify high-risk cases without staining because iodine causes discomfort and prolongs examination times. This study assessed the capability of an artificial intelligence (AI) system to predict multiple LVLs from images that had not been stained with iodine as well as patients at high risk for esophageal cancer. Methods We constructed the AI system by preparing a training set of 6634 images from white-light and narrow-band imaging in 595 patients before they underwent endoscopic examination with iodine staining. Diagnostic performance was evaluated on an independent validation dataset (667 images from 72 patients) and compared with that of 10 experienced endoscopists. Results The sensitivity, specificity, and accuracy of the AI system to predict multiple LVLs were 84.4 %, 70.0 %, and 76.4 %, respectively, compared with 46.9 %, 77.5 %, and 63.9 %, respectively, for the endoscopists. The AI system had significantly higher sensitivity than 9/10 experienced endoscopists. We also identified six endoscopic findings that were significantly more frequent in patients with multiple LVLs; however, the AI system had greater sensitivity than these findings for the prediction of multiple LVLs. Moreover, patients with AI-predicted multiple LVLs had significantly more cancers in the esophagus and head and neck than patients without predicted multiple LVLs. Conclusion The AI system could predict multiple LVLs with high sensitivity from images without iodine staining. The system could enable endoscopists to apply iodine staining more judiciously.
3 October 2020 in Gastric Cancer
20 May 2024 in Surgical Endoscopy
29 March 2023 in Digestive Diseases
Background: Endoscopic submucosal dissection (ESD) for superficial esophageal cancer is technically challenging, and research on predictive factors related to the difficulty in the procedure is limited. This study aimed to investigate the factors predicting the difficulty in esophageal ESD. Methods: This retrospective study analyzed 303 lesions treated at our institution between April 2005 and June 2021. The following 13 factors were evaluated: sex, age, tumor location, tumor localization, macroscopic type, tumor size, tumor circumference, preoperative diagnosis of histological type, preoperative diagnosis of invasion depth, previous radiotherapy for esophageal cancer, metachronous lesion located close to post-ESD scar, operator’s skill, and use of a clip-and-thread traction method. Difficult esophageal ESD cases were defined as those requiring long procedure time (>120 min). Results: Fifty-one lesions (16.8%) met the defined criterion for difficult cases of esophageal ESD. Logistic regression analysis identified tumor size larger than 30 mm (odds ratio: 9.17, 95% confidence interval: 4.27–19.69, p < 0.001) and tumor circumference more than half that of the esophagus (odds ratio 2.53, 95% confidence interval: 1.15–5.54, p = 0.021) as independent predictive factors related to difficulty in esophageal ESD. Conclusion: Tumor size larger than 30 mm and tumor circumference more than half that of the esophagus can predict difficulty in performing esophageal ESD. This knowledge can provide useful information for developing ESD strategies and selecting a suitable operator on a case-by-case basis to achieve favorable clinical outcomes.
12 April 2024 in Esophagus