Rifqi Fajar Maulana

Rifqi Fajar Maulana

Auto-generated profile, based on publicly available information

Rifqi Fajar Maulana

Institute of Atomic and Molecular Sciences

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2025 in Journal of the Chinese Chemical Society
Verified
Journal Article
Closed access
RMRifqi Fajar Maulana
Rifqi Fajar Maulana
AHAndri Hardiansyah
Andri Hardiansyah
AHAngga Hermawan
Angga Hermawan
NSNi Luh Wulan Septiani
Ni Luh Wulan Septiani
ASAkhmad Sabarudin
Akhmad Sabarudin
Ting-Yu LiuTing-Yu Liu
Ting-Yu Liu

25 June 2026 in ChemRxiv
Verified
Preprint
Open access
PDF file
HSHan-Sheng Sun
Han-Sheng Sun
ANAi-Phuong Nguyen
Ai-Phuong Nguyen
CRCarlos Jose Quiroz Reyes
Carlos Jose Quiroz Reyes
YLYa Chen Li
Ya Chen Li
JLJoshua M. Lim
Joshua M. Lim
CLChing-Wei Lin
Ching-Wei Lin
Fluorescent quantum defects in single-wall carbon nanotubes (SWCNTs) are a major advance in nanocarbon research, owing to their bright, single-photon emission at telecom wavelengths and versatile conjugation chemistries for biomedical sensing and disease targeting. Here, we introduce an efficient, oxygen-free sonochemical route that generates long-chain alkyl defects, simultaneously shortening nanotubes and producing a bright, homogeneously emissive (6,5) SWCNT ensemble. Among 15 screened surfactants and initiators, the branched-chain Niaproof ® 4, which molecular dynamics simulations show packs more densely and uniformly than linear surfactants, yields a 3.4-fold brightness enhancement and a sharp emission peak near 1108 nm. Single-particle spectroscopy reveals J-aggregate emission redshifts at high defect densities, and fibrinogen titration shows defect chemistry governs protein-driven coating displacement. Using a home-built short-wave infrared imaging system (25 mW cm −2 , 989 nm excitation, 1150 nm longpass collection), we show that these sparse defects (~15.2 μm −1 ) drive different, nonmonotonic pharmacokinetics between Niaproof ® 4– and lipid-PEG–functionalized (6,5) at early time points, converging as protein-corona formation masks the underlying chemistry. Histology localizes the nanotubes within macrophages of mononuclear phagocyte system–associated organs. Intravenous administration (50 μg kg −1 ) shows no acute toxicity and short ~2-day retention, while the Niaproof ® 4 group depletes more myeloid cells after corona formation.