Traditionally, transvenous implantable cardioverter-defibrillators (ICDs) have served as the cornerstone of sudden cardiac death treatment; however, transvenous implantable ICDs carry significant short- and long-term risks of complications associated with intravascular and intracardiac leads. Attempts to migrate from the transvenous components resulted in the development of the subcutaneous ICD, which successfully terminates life-threatening ventricular tachyarrhythmias. However, the subcutaneous ICD has limitations, including the need for higher defibrillation energy, a lack of bradycardic pacing, and a lack of antitachycardia pacing for terminating ventricular tachycardias. The Aurora Extravascular ICD (ICD, Medtronic, Minneapolis, MN) introduces a novel substernal lead placement and represents a notable advancement in the prevention of sudden cardiac death from ventricular tachyarrhythmias by integrating defibrillation therapy with short-term bradycardia and antitachycardia pacing capabilities without the need for transvenous leads. With the introduction of this novel device in clinical practice, anesthesiologists need to understand what makes the extravascular ICD system unique and how to manage it appropriately during the perioperative period.
31 January 2024 in Seminars in Cardiothoracic and Vascular Anesthesia
Failure to provide one-lung ventilation can prohibit minimally invasive thoracic surgeries. Strategies for one-lung ventilation include double-lumen endotracheal tubes or endobronchial blockers, but rarely both. Inability to provide lung isolation after double-lumen endotracheal tube placement requires troubleshooting and sometimes the use of extra equipment. This case describes using a unique Y-shaped endobronchial blocker placed through a left-sided double-lumen endotracheal tube after failure to achieve lung isolation with a double-lumen endotracheal tube alone.
10 January 2023 in Seminars in Cardiothoracic and Vascular Anesthesia
The presence of a tracheal bronchus, which is often incidentally discovered, complicates endotracheal intubation and lung isolation during thoracic surgery. Prior reports of successful right-sided lung isolation in the presence of tracheal bronchus required utilization of a double lumen tube. Although right-sided lung isolation was required in our case, due to other patient factors, it was determined that a double lumen tube of a suitable size would be unlikely to be placed safely and successfully. We describe the successful use of a Rüsch EZ-Blocker bronchial blocker in obtaining right-sided isolation in a patient with a difficult airway and tracheal bronchus.
27 June 2024 in Journal of Cardiothoracic and Vascular Anesthesia