In this study, a new approach to measure local electrical conductivity in tissue is presented, which is based on the propagating B phase and the homogeneous Helmholtz equation. This new MRI technique might open future opportunities for tumor and lesion characterization based on conductivity differences, while it may also find application in radio frequency safety assessment. Prerequisites for conductivity mapping using only the B phase (instead of the complex B field) are addressed. Furthermore it was found that the B phase can be derived directly from the measurable transceive phase arg(BB) in the head. Validation for a human head excited by a 7 T‐birdcage coil using simulations and measurements showed that it is possible to measure in vivo conductivity patterns in the brain using B phase information only. Conductivity contrast between different brain tissues is clearly observed. The measured mean values for white matter, gray matter and cerebrospinal fluid differed 54%, 26%, and −13% respectively from literature values. The proposed method for B phase measurements is very suited for in vivo applications, as the measurement is short (less than a minute per imaged slice) and exposes the patient to low RF power, contrary to earlier proposed approaches. Magn Reson Med, 2012.
To evaluate prostate intrafraction motion using MRI during the full course of online adaptive MR-Linac radiotherapy (RT) fractions, in preparation of MR-guided extremely hypofractionated RT. Five low and intermediate risk prostate cancer patients were treated with 20 x 3.1 Gy fractions on a 1.5T MR-Linac. Each fraction, initial MRI (Pre) scans were obtained at the start of every treatment session. Pre-treatment planning MRI contours were propagated and adapted to this Pre scan after which plan re-optimization was started in the treatment planning system followed by dose delivery. 3D Cine-MR imaging was started simultaneously with beam-on and acquired over the full beam-on period. Prostate intrafraction motion in this cine-MR was determined with a previously validated soft-tissue contrast based tracking algorithm. In addition, absolute accuracy of the method was determined using a 4D phantom. Prostate motion was completely automatically determined over the full on-couch period (approx. 45 min) with no identified mis-registrations. The translation 95% confidence intervals are within clinically applied margins of 5 mm, and plan adaption for intrafraction motion was required in only 4 out of 100 fractions. This is the first study to investigate prostate intrafraction motions during entire MR-guided RT sessions on an MR-Linac. We have shown that high quality 3D cine-MR imaging and prostate tracking during RT is feasible with beam-on. The clinically applied margins of 5 mm have proven to be sufficient for these treatments and may potentially be further reduced using intrafraction plan adaptation guided by cine-MR imaging.
11 February 2013 in Magnetic Resonance in Medicine