F.B. Dudieva

F.B. Dudieva

Auto-generated profile, based on publicly available information

F.B. Dudieva

Krasnov Research Institute of Eye Disease

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2021 in Ophthalmology in Russia
Verified
Journal Article
Open access
PDF file
DPD. V. Petrachkov
D. V. Petrachkov
LAL. Alkharki
L. Alkharki
AMA. G. Matyushchenko
A. G. Matyushchenko
VFV. M. Filippov
V. M. Filippov
FDF. K. Dudieva
F. K. Dudieva
Macular hole (MH) is one of the most common pathologies of the macular area of the retina which leads to a significant decrease in visual acuity. The article presents early comparative morphofunctional results of surgical treatment of 60 patients (22 men and 38 women) with MH of the III–IV stages according to Gass and the minimum diameter (MinD) MH 404–696 microns. All patients included in the study had pseudophakia and have not previously undergone endovitreal interventions. Patients with MH with a diameter of 404–696 μm were randomized and divided into 3 equal groups: after three-port 25G pars plana posterior vitrectomy the patients of the first group underwent peeling of the inner limited membrane (ILM) with the convergence of the edges of MH and vitreous cavity tamponade with 16 % gas-air mixture of perfluoropropane (C2F6). In the area of the macular defect, patients of the second group underwent application of autologous conditioned plasma (ACP) in the PFСs environment and the convergence of the edges of MH. In patients of the third group, MH was closed using the technique of an inverted ILM flap. In patients of groups 2 and 3 the operation was completed by tamponade of the vitreous cavity with sterile air. Standard and special research methods, such as optical coherence tomography of the macular zone, were performed before surgery, 5 days and 1 month after surgery in all patients from groups 2 and 3. Patients from group 1 were examined before surgery and 1 month after surgical treatment, due to the long-lasting gas-air mixture in the vitreous cavity. Restoration of the correct structure of the fovea with the formation of U- and V-shaped profile during OCT after 1 month was noted in all cases. The data obtained demonstrate the peculiarities of using the inverted ILM flap and ACP methods in comparison with the traditional method of MH closure with a gas-air mixture.

16 October 2026 in Russian Annals of Ophthalmology
Verified
Journal Article
Closed access
Sergei AvetisovSergei Avetisov
Sergei Avetisov
ECE.A. Chizhonkova
E.A. Chizhonkova
KAK.S. Avetisov
K.S. Avetisov
XIX.I. Isaakidis
X.I. Isaakidis
TST.V. Sharnina
T.V. Sharnina
HYH. Ben Hadj Younes
H. Ben Hadj Younes
The review presents the findings of studies on the clinical use of ultrasound biomicroscopy and anterior segment optical coherence tomography in the diagnosis of natural lens dislocation.

23 April 2024 in Russian Annals of Ophthalmology
Verified
Journal Article
Closed access
AKA.A. Kasyanov
A.A. Kasyanov
NSN.YU. Shkolyarenko
N.YU. Shkolyarenko
FDF.B. Dudieva
F.B. Dudieva
TST.V. Sharnina
T.V. Sharnina
Purpose. This study compares the functional outcomes of correction using two different types of aberrational extended depth-of-focus (EDOF) intraocular lenses (IOLs). Material and methods. The study was conducted in two standardized groups (20 patients, 20 eyes in each group). Patients in group 1 were implanted EDOF IOL I, in group 2 — EDOF IOL II. The main selection criterion was stable postoperative refraction close to emmetropia, with a minimum follow-up period of 3 months. Uncorrected visual acuity (UCVA) was chosen as the primary assessment criterion and was evaluated monocularly under photopic conditions at the following distances: at far, 66 cm, 50 cm, 40 cm, and 33 cm. Results. The conducted analysis showed that both lenses provided a comparable high level of UCVA for distance vision in groups 1 and 2, with statistically insignificant differences (p=0.2538; U=160.52). Significantly better results at intermediate distances and at 50 cm were achieved in group 1 (p=0.0235; U=118.02 and p=0.0124; U=109.0, respectively). For the near distance of 40 cm, group 1 also demonstrated better outcomes, although the difference was not statistically significant (p=0.0720; U=134.52). At the near distance of 33 cm, both groups achieved an expectedly similar level of UCVA, with no statistically significant difference (p=0.4656; U=173.52). No positive dysphotopsia was reported in either group. Conclusion. Both EDOF IOLs demonstrated high clinical effectiveness. A significantly higher level of functional outcomes at intermediate distances was achieved with IOL I.