Background The diagnosis of acute aortic syndrome (AAS) is commonly delayed or missed in the ED. We describe characteristics of ED attendances with symptoms potentially associated with AAS, diagnostic performance of clinical decision tools (CDTs) and physicians and yield of CT aorta angiogram (CTA). Methods This was a multicentre observational cohort study of adults attending 27 UK EDs between 26 September 2022 and 30 November 2022, with potential AAS symptoms: chest, back or abdominal pain, syncope or symptoms related to malperfusion. Patients were preferably identified prospectively, but retrospective recruitment was also permitted. Anonymised, routinely collected patient data including components of CDTs, was abstracted. Clinicians treating prospectively identified patients were asked to record their perceived likelihood of AAS, prior to any confirmatory testing. Reference standard was radiological or operative confirmation of AAS. 30-day electronic patient record follow-up evaluated whether a subsequent diagnosis of AAS had been made and mortality. Results 5548 patients presented, with a median age of 55 years (IQR 37–72; n=5539). 14 (0.3%; n=5353) had confirmed AAS. 10/1046 (1.0%) patients in whom the ED clinician thought AAS was possible had AAS. 5/147 (3.4%) patients in whom AAS was considered the most likely diagnosis had AAS. 2/3319 (0.06%) patients in whom AAS was considered not possible did have AAS. 540 (10%; n=5446) patients underwent CT, of which 407 were CTA (7%). 30-day follow-up did not reveal any missed AAS diagnoses. AUROC (area under the receiver operating characteristic) curve for ED clinician AAS likelihood rating was 0.958 (95% CI 0.933 to 0.983, n=4006) and for individual CDTs were: Aortic Dissection Detection Risk Score (ADD-RS) 0.674 (95% CI 0.508 to 0.839, n=4989), AORTAs 0.689 (95% CI 0.527 to 0.852, n=5132), Canadian 0.818 (95% CI 0.686 to 0.951, n=5180) and Sheffield 0.628 (95% CI 0.467 to 0.788, n=5092). Conclusion Only 0.3% of patients presenting with potential AAS symptoms had AAS but 7% underwent CTA. CDTs incorporating clinician gestalt appear to be most promising, but further prospective work is needed, including evaluation of the role of D-dimer. Trial registration number NCT05582967; NCT05582967.
Introduction: Missed fractures are the most frequent diagnostic error attributed to clinicians in UK emergency departments and a significant cause of patient morbidity. Recently, advances in computer vision have led to artificial intelligence (AI)-enhanced model developments, which can support clinicians in the detection of fractures. Previous research has shown these models to have promising effects on diagnostic performance, but their impact on the diagnostic accuracy of clinicians in the National Health Service (NHS) setting has not yet been fully evaluated. Methods and analysis: A dataset of 500 plain radiographs derived from Oxford University Hospitals (OUH) NHS Foundation Trust will be collated to include all bones except the skull, facial bones and cervical spine. The dataset will be split evenly between radiographs showing one or more fractures and those without. The reference ground truth for each image will be established through independent review by two senior musculoskeletal radiologists. A third senior radiologist will resolve disagreements between two primary radiologists. The dataset will be analysed by a commercially available AI tool, BoneView (Gleamer, Paris, France), and its accuracy for detecting fractures will be determined with reference to the ground truth diagnosis. We will undertake a multiple case multiple reader study in which clinicians interpret all images without AI support, then repeat the process with access to AI algorithm output following a 4-week washout. 18 clinicians will be recruited as readers from four hospitals in England, from six distinct clinical groups, each with three levels of seniority (early-stage, mid-stage and later-stage career). Changes in the accuracy, confidence and speed of reporting will be compared with and without AI support. Readers will use a secure web-based DICOM (Digital Imaging and Communications in Medicine) viewer ( www.raiqc.com ), allowing radiograph viewing and abnormality identification. Pooled analyses will be reported for overall reader performance as well as for subgroups including clinical role, level of seniority, pathological finding and difficulty of image. Ethics and dissemination: The study has been approved by the UK Healthcare Research Authority (IRAS 310995, approved on 13 December 2022). The use of anonymised retrospective radiographs has been authorised by OUH NHS Foundation Trust. The results will be presented at relevant conferences and published in a peer-reviewed journal. Trial registration numbers: This study is registered with ISRCTN ( ISRCTN19562541 ) and ClinicalTrials.gov ( NCT06130397 ). The paper reports the results of a substudy of STEDI2 (Simulation Training for Emergency Department Imaging Phase 2).
Background Standardisation of referral pathways and the transfer of patients with acute aortic syndromes (AAS) to regional centres are recommended by NHS England in the Acute Aortic Dissection Toolkit. The aim of the Transfer of Thoracic Aortic Vascular Emergencies to Regional Specialist INstitutes Group study was to establish an interdisciplinary consensus on the interhospital transfer of patients with AAS to specialist high-volume aortic centres. Methods Consensus on the key aspects of interhospital transfer of patients with AAS was established using the Delphi method, in line with Conducting and Reporting of Delphi Studies guidelines. A national patient charity for aortic dissection was involved in the design of the Delphi study. Vascular and cardiothoracic surgeons, emergency physicians, interventional radiologists, cardiologists, intensivists and anaesthetists in the United Kingdom were invited to participate via their respective professional societies. Results Three consecutive rounds of an electronic Delphi survey were completed by 212, 101 and 58 respondents, respectively. Using predefined consensus criteria, 60 out of 117 (51%) statements from the survey were included in the consensus statement. The study concluded that patients can be taken directly to a specialist aortic centre if they have typical symptoms of AAS on the background of known aortic disease or previous aortic intervention. Accepted patients should be transferred in a category 2 ambulance (response time <18 min), ideally accompanied by transfer-trained personnel or Adult Critical Care Transfer Services. A clear plan should be agreed in case of a cardiac arrest occurring during the transfer. Patients should reach the aortic centre within 4 hours of the initial referral from their local hospital. Conclusions This consensus statement is the first set of national interdisciplinary recommendations on the interhospital transfer of patients with AAS. Its implementation is likely to contribute to safer and more standardised emergency referral pathways to regional high-volume specialist aortic units.
Background: D-dimer is the only biomarker currently recommended in guidelines for the diagnosis of acute aortic syndrome (AAS). We undertook a systematic review to determine whether any alternative biomarkers could be useful in AAS diagnosis.Methods: We searched electronic databases (including MEDLINE, EMBASE and the Cochrane Library) from inception to February 2024. Diagnostic studies were eligible if they examined biomarkers other than D-dimer for diagnosing AAS compared with a reference standard test in people presenting to the ED with symptoms of AAS. Case-control studies were identified but excluded due to high risk of bias. Selection of studies, data extraction and risk of bias assessments using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool were undertaken independently by at least two reviewers. We used narrative synthesis to summarise the findings.Results: We identified 2017 citations, included 13 cohort studies (n=76–999), and excluded 38 case-control studies. Methodological quality was variable, with most included studies having unclear or high risk of bias and applicability concerns in at least one item of the QUADAS‐2 tool. Only two studies reported biomarkers with sensitivity and specificity comparable to D-dimer (ie, >90% and >50%, respectively). Wanget alreported 99.1% sensitivity and 84.9% specificity for soluble ST2; however, these findings conflicted with estimates of 58% sensitivity and 70.8% specificity reported in another study. Chun and Siu reported 95.6% sensitivity and 56.1% specificity for neutrophil count, but this has not been confirmed elsewhere.Conclusion: There are many potential alternative biomarkers for AAS but few have been evaluated in more than one study, study designs are often weak and reported biomarker accuracy is modest or inconsistent between studies. Alternative biomarkers to D-dimer are not ready for routine clinical use.PROSPERO registration number: CRD42022252121.
Background Acute aortic syndrome (AAS) requires urgent diagnosis with computed tomographic angiography (CTA). Diagnostic strategies need to weigh the benefits of detecting AAS against the costs of using CTA with a low yield of AAS when the prevalence of AAS is low. We aimed to estimate the cost-effectiveness of diagnostic strategies using clinical probability scoring and D-dimer to select patients with potential symptoms of AAS for CTA. Methods We developed a decision analytical model to simulate the management of patients attending hospital with possible AAS. We modelled diagnostic strategies that used the Aortic Dissection Detection Risk Score (ADD-RS) and D-dimer to select patients for CTA. We used estimates from our meta-analysis, existing literature and clinical experts to model the consequences of diagnostic strategies on survival, health utility, and health and social care costs. We estimated the incremental cost per quality-adjusted life-years gained by each strategy compared with the next most effective alternative on the efficiency frontier. Results A strategy based on the Canadian guideline (CTA if ADD-RS>1 or ADD-RS=1 with D-dimer >500 ng/mL) is cost-effective but would result in high rates of CTA if applied to an unselected population (AAS prevalence 0.26%). The strategy is also cost-effective and would result in lower rates of CTA if applied to a more selected population, such as those with a non-zero clinical suspicion of AAS (prevalence 0.61%). For patients currently receiving CTA, using ADD-RS>1 or D-dimer >500 ng/mL to select patients for CTA is cost-effective. Conclusions A strategy using ADD-RS>1 or ADD-RS=1 with D-dimer >500 ng/mL to select patients for CTA appears cost-effective but primary research is required to evaluate this strategy in practice and determine how suspicion of AAS is identified.
Background: Acute aortic syndrome is a life-threatening condition that requires urgent diagnosis with computed tomographic angiography. Diagnostic technologies, including clinical scores and biomarkers, can be used to select patients presenting with potential symptoms of acute aortic syndrome for computed tomographic angiography. Objectives: We aimed to estimate the accuracy of clinical scores and biomarkers for diagnosing acute aortic syndrome, the cost-effectiveness of alternative diagnostic strategies and the expected value of future research. Methods: We searched online databases from inception to February 2024, reference lists of included studies and existing systematic reviews. We included cohort studies evaluating the accuracy of clinical scores or biomarkers for diagnosing acute aortic syndrome compared with a reference standard. Two authors independently selected and extracted data. Risk of bias was appraised using the quality assessment of diagnostic accuracy studies-2 tool. Data were synthesised using either a multinomial or a bivariate normal meta-analysis model. We developed a decision-analytic model to simulate the management of a hypothetical cohort of patients attending hospital with possible acute aortic syndrome. We modelled diagnostic strategies that used the Aortic Dissection Detection Risk Score and D-dimer to select patients for computed tomographic angiography. We used estimates from our meta-analysis, existing literature and clinical experts to model the consequences of diagnostic strategies upon survival, health utility and healthcare costs. We estimated the incremental cost per quality-adjusted life-year gained by each strategy compared to the next most effective alternative on the efficiency frontier, and the expected value of perfect information. Results: Primary meta-analysis included 12 studies of Aortic Dissection Detection Risk Score alone, 6 studies of Aortic Dissection Detection Risk Score with D-dimer and 18 studies of D-dimer using the 500 ng/ml threshold. Sensitivities and specificities (95% credible intervals) were: Aortic Dissection Detection Risk Score > 0 94.6% (90% to 97.5%) and 34.7% (20.7% to 51.2%), Aortic Dissection Detection Risk Score > 1 43.4% (31.2% to 57.1%) and 89.3% (80.4% to 94.8%); Aortic Dissection Detection Risk Score > 0 or D-dimer > 500 ng/ml 99.8% (98.7% to 100%) and 21.8% (12.1% to 32.6%); Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml 98.3% (94.9% to 99.5%) and 51.4% (38.7% to 64.1%); Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml 93.1% (87.1% to 96.3%) and 67.1% (54.4% to 77.7%); and D-dimer alone 96.5% (94.8% to 98%) and 56.2% (48.3% to 63.9%). We identified 11 cohort studies of other biomarkers, but accuracy estimates were limited and inconsistent. Decision-analytic modelling showed that applying diagnostic strategies to an unselected population (acute aortic syndrome prevalence 0.26%) resulted in high rates of computed tomographic angiography, and only the strategy selecting patients with Aortic Dissection Detection Risk Score > 1 for computed tomographic angiography was cost-effective. If clinicians can select a population for investigation with higher acute aortic syndrome prevalence (0.61%), then using a strategy of Aortic Dissection Detection Risk Score > 1 or Aortic Dissection Detection Risk Score = 1 with D-dimer > 500 ng/ml or a strategy of Aortic Dissection Detection Risk Score > 1 or D-dimer > 500 ng/ml to select patients for computed tomographic angiography is cost-effective and deliverable. At a threshold of £20,000/quality-adjusted life-year, population expected value of perfect information was around £17.75M. Limitations: Studies included in the meta-analysis showed substantial heterogeneity in estimates of specificity. In the modelling, there was substantial uncertainty around what constitutes suspected acute aortic syndrome and the effect of delayed diagnosis. Conclusions: The Aortic Dissection Detection Risk Score and D-dimer provide useful diagnostic information and may offer cost-effective strategies for selecting patients for computed tomographic angiography, but their role depends upon how clinicians identify suspected acute aortic syndrome. Future work: Primary research is required to compare different combinations of Aortic Dissection Detection Risk Score with D-dimer in practice, explore how suspected acute aortic syndrome is identified and evaluate alternative biomarkers. Funding: This synopsis presents independent research funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme as award number NIHR151853.