Christopher J. Crabtree

Christopher J. Crabtree

Auto-generated profile, based on publicly available information

Christopher J. Crabtree

School of Engineering and Computing Sciences Durham University Durham DH1 3LE UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012 in Wind Energy
Verified
Journal Article
Closed access
PDF file
Wenxian YangWenxian Yang
Wenxian Yang
PTPeter J. Tavner
Peter J. Tavner
CCChristopher J. Crabtree
Christopher J. Crabtree
YFY. Feng
Y. Feng
YQY. Qiu
Y. Qiu

22 September 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Wenxian YangWenxian Yang
Wenxian Yang
PTPeter J. Tavner
Peter J. Tavner
CCChristopher J. Crabtree
Christopher J. Crabtree
MWMichael Wilkinson
Michael Wilkinson
Cost-effective wind turbine (WT) condition monitoring assumes more importance as turbine sizes increase and they are placed in more remote locations, for example, offshore. Conventional condition monitoring techniques, such as vibration, lubrication oil, and generator current signal analysis, require the deployment of a variety of sensors and computationally intensive analysis techniques. This paper describes a WT condition monitoring technique that uses the generator output power and rotational speed to derive a fault detection signal. The detection algorithm uses a continuous-wavelet-transform-based adaptive filter to track the energy in the prescribed time-varying fault-related frequency bands in the power signal. The central frequency of the filter is controlled by the generator speed, and the filter bandwidth is adapted to the speed fluctuation. Using this technique, fault features can be extracted, with low calculation times, from direct- or indirect-drive fixed- or variable-speed WTs. The proposed technique has been validated experimentally on a WT drive train test rig. A synchronous or induction generator was successively installed on the test rig, and both mechanical and electrical fault like perturbations were successfully detected when applied to the test rig.

17 July 2012 in Wind Energy
Verified
Journal Article
Closed access
YFYanhui Feng
Yanhui Feng
YQYingning Qiu
Yingning Qiu
CCChristopher J. Crabtree
Christopher J. Crabtree
HLHui Long
Hui Long
PTPeter J. Tavner
Peter J. Tavner

1 March 2010 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
SWSimon Watson
Simon Watson
BXBeth J. Xiang
Beth J. Xiang
Wenxian YangWenxian Yang
Wenxian Yang
PTPeter J. Tavner
Peter J. Tavner
CCChristopher J. Crabtree
Christopher J. Crabtree
With an increasing number of wind turbines being erected offshore, there is a need for cost-effective, predictive, and proactive maintenance. A large fraction of wind turbine downtime is due to bearing failures, particularly in the generator and gearbox. One way of assessing impending problems is to install vibration sensors in key positions on these subassemblies. Such equipment can be costly and requires sophisticated software for analysis of the data. An alternative approach, which does not require extra sensors, is investigated in this paper. This involves monitoring the power output of a variable-speed wind turbine generator and processing the data using a wavelet in order to extract the strength of particular frequency components, characteristic of faults. This has been done for doubly fed induction generators (DFIGs), commonly used in modern variable-speed wind turbines. The technique is first validated on a test rig under controlled fault conditions and then is applied to two operational wind turbine DFIGs where generator shaft misalignment was detected. For one of these turbines, the technique detected a problem 3 months before a bearing failure was recorded.

3 August 2015 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Open access
CCChristopher J Crabtree
Christopher J Crabtree
DZDonatella Zappalá
Donatella Zappalá
SHSimon I Hogg
Simon I Hogg
This paper presents a discussion of the development of wind energy generation in the United Kingdom and the challenges faced by the wind industry including reliability, performance and condition monitoring, particularly in the offshore environment. The worldwide installed capacity of offshore wind has now risen to over 7 GW, with an ever increasing deployment rate of new assets. About 90% of the global currently installed capacity is in Northern Europe, with the United Kingdom having the world's largest share at 4 GW. Capacity factor data from UK offshore wind farms is presented, providing an insight into the current performance of large Round 2 offshore wind farms compared to the earlier Round 1 farms and to onshore farms. The data reveal that the United Kingdom's Round 2 offshore farms are achieving an average monthly capacity factor of 38.3% with a peak value of 75.8%. The older Round 1 farms have a lower average capacity factor of 33.6% while large onshore farms with capacities above 100 MW have achieved 25.6%. Offshore wind turbine performance has improved over time, and the industry is applying the learning from early experiences to achieve better performances at the more recently installed farms. Despite these improvements in turbine availability, the cost of energy from wind, particularly offshore, remains too high for it to be a commercially viable form of generation without subsidies. Reducing the cost of energy from wind to economically sustainable levels is the most important challenge facing the industry today. Operation and maintenance costs constitute up to 30 % of the total cost of energy from wind in large farms. The industry must overcome the challenges associated with improving component reliability and the development and adoption by operators of appropriate condition monitoring systems and maintenance strategies, in order to reduce costs to sustainable levels. Research and development work carried out with these goals in mind is also reviewed in the paper.

1 May 2014 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
DZDonatella Zappalá
Donatella Zappalá
PTPeter J. Tavner
Peter J. Tavner
CCChristopher J. Crabtree
Christopher J. Crabtree
Shawn ShengShawn Sheng
Shawn Sheng
Improving the availability of wind turbines is critical for minimising the cost of wind energy, especially offshore. The development of reliable and cost‐effective gearbox condition monitoring systems (CMSs) is of concern to the wind industry, because the gearbox downtime has a significant effect on the wind turbine availabilities. Timely detection and diagnosis of developing gear defects is essential for minimising an unplanned downtime. One of the main limitations of most current CMSs is the time consuming and costly manual handling of large amounts of monitoring data, therefore automated algorithms would be welcome. This study presents a fault detection algorithm for incorporation into a commercial CMS for automatic gear fault detection and diagnosis. Based on the experimental evidence from the Durham Condition Monitoring Test Rig, a gear condition indicator was proposed to evaluate the gear damage during non‐stationary load and speed operating conditions. The performance of the proposed technique was then successfully tested on signals from a full‐size wind turbine gearbox that had sustained gear damage, and had been studied in a National Renewable Energy Laboratory's (NREL) programme. The results show that the proposed technique proves efficient and reliable for detecting gear damage. Once implemented into the wind turbine CMSs, this algorithm can automate the data interpretation, thus reducing the quantity of the information that the wind turbine operators must handle.