Jenny Maribel Moscoso Carrasco

Jenny Maribel Moscoso Carrasco

Auto-generated profile, based on publicly available information

Jenny Maribel Moscoso Carrasco

Aliada Centro Oncologico—Lima, Peru

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2021 in Ophthalmic Epidemiology
Verified
Journal Article
Closed access
ABAntonio Barrenechea-Pulache
Antonio Barrenechea-Pulache
APAndres Portocarrero-Bonifaz
Andres Portocarrero-Bonifaz
AHAkram Hernández-Vásquez
Akram Hernández-Vásquez
CPCarlos Portocarrero-Ramos
Carlos Portocarrero-Ramos
JMJenny Moscoso-Carrasco
Jenny Moscoso-Carrasco
This study analyzes the factors associated with eye care service utilization among Peruvians 50 years of age and older, measured as self-reporting of having undergone examination of visual acuity d...

5 April 2022 in REVISTA PERUANA DE CIENCIAS DE LA SALUD
Verified
Journal Article
Open access
PDF file
GCGuillermo Ulises Salazar Cáceres
Guillermo Ulises Salazar Cáceres
MPMaricruz Jesús Salomón Prado
Maricruz Jesús Salomón Prado
AMAnggie Claudia Niño Mauricio
Anggie Claudia Niño Mauricio
MTMarcia Chumbes Taipe
Marcia Chumbes Taipe
FPFátima Caballero Pignataro
Fátima Caballero Pignataro
CCCarmen Guzman Calcina
Carmen Guzman Calcina
Objective. To evaluate the influence of the use of face masks on resting heartrate (HR) and physical activity in adults aged 18 to 60 years, in the city of Lima, during the COVID-19 pandemic in 2020. Methods. An experimental, analytical, prospective and cross-sectional study was carried out. For data collection, a virtual survey was carried out via Google Forms, with a series of questions and indications for the correct measurement of HR in different situations: at rest, immediately after activity and 5 min after physical activity with and without the use of masks (KN95, fabric, surgical and N95). For the present study, the possible causes of increased HR were analyzed, so 60 asymptomatic adults, 40 women and 20 men, in the age range of 18 to 60 years, were selected. Results. It was found that the difference in mean HR with and without mask use immediatelyafter physical activity increased signifcantly depending on the type of mask. With respect to the KN95, an increase of up to 9.6 beats/min was observed, while the fabric, surgical and N95 masks showed an increase of 5.9, 5.6 and 7.4 beats/min, respectively, under the same conditions, calculating an average of 112.7 beats/min over 10.6 beats/min at rest, showing an increase of up to 7% of its value at rest. Results. It was obtained that the difference in the average HR with and without mask use immediately after physical activity increased signifcantly depending onthe type of mask. With respect to KN95, an increase of up to 9,6 beats/min was observed, while cloth, surgical and N95 masks showed an increase of 5,9, 5,6 and 7,4 beats/min, respectively, under the same conditions, calculated at an averageof 112.7 beats/min over 10,6 beats/min at rest, evidencing an increase in up to 7 % of their value at rest. Conclusion. It was found that the use of the face mask exerts a notable influence on HR, immediately and 5 minutes after the end of the physical activity, being the KN95 the most used face mask and the one with the greatest influence on the cardiac pulse.

5 September 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
SLS Leon
S Leon
OPO Paucar
O Paucar
NCN Correa
N Correa
MGM Glassell
M Glassell
AGA Gonzales
A Gonzales
DRD Roa
D Roa
Objective. The goal of this study was to use Monte Carlo (MC) simulations and measurements to investigate the dosimetric suitability of an interventional radiology (IR) c-arm fluoroscope to deliver low-dose radiotherapy to the lungs. Approach. A previously-validated MC model of an IR fluoroscope was used to calculate the dose distributions in a COVID-19-infected patient, 20 non-infected patients of varying sizes, and a postmortem subject. Dose distributions for PA, AP/PA, 3-field and 4-field treatments irradiating 95% of the lungs to a 0.5 Gy dose were calculated. An algorithm was created to calculate skin entrance dose as a function of patient thickness for treatment planning purposes. Treatments were experimentally validated in a postmortem subject by using implanted dosimeters to capture organ doses. Main results. Mean doses to the left/right lungs for the COVID-19 CT data were 1.2/1.3 Gy, 0.8/0.9 Gy, 0.8/0.8 Gy and 0.6/0.6 Gy for the PA, AP/PA, 3-field, and 4-field configurations, respectively. Skin dose toxicity was the highest probability for the PA and lowest for the 4-field configuration. Dose to the heart slightly exceeded the ICRP tolerance; all other organ doses were below published tolerances. The AP/PA configuration provided the best fit for entrance skin dose as a function of patient thickness (R 2 = 0.8). The average dose difference between simulation and measurement in the postmortem subject was 5%. Significance. An IR fluoroscope should be capable of delivering low-dose radiotherapy to the lungs with tolerable collateral dose to nearby organs.