1 December 2025 in Review of Scientific Instruments
Due to the excellent sensitivity for small torque, torsion pendulums are widely used. The thermal noise is a fundamental limit according to the fluctuation–dissipation theorem. The damping induced by the eddy current has been well studied, but it has not been verified directly whether the eddy current generates the Brownian motion in accordance with the fluctuation–dissipation theorem for a macroscopic pendulum. In this work, we verify the Brownian motion induced by the eddy current using torsion pendulums in the geomagnetic field. For a hollow cube aluminum pendulum with a side length of 50 mm and thickness of 1 mm, the measured torque noise is about 1×10−15Nm/Hz, consistent with the thermal noise predicted by the eddy current in a 60.5 μT ambient magnetic field. By applying the magnetic shield for a disk-shaped pendulum, the torque noise is improved to 1×10−16Nm/Hz and reaches the thermal noise limit with quality factor Q = 4.3 × 105.
1 July 2025 in Review of Scientific Instruments
Outgassing, defined as the continuous release of gas molecules from the surface of materials, is a common issue in vacuum research. Although the quantity of desorbed molecules is generally small, its impact becomes significant in high-precision scientific missions, such as the space-borne gravitational-wave (GW) detection. The detailed evaluation of this noise source relies on the outgassing rate for materials applied, while the current measurement methods all show insufficient precision, lacking practicability in measuring small-sized samples. In this paper, a new outgassing rate measurement method based on high-precision torsion balance is proposed. Unlike the general methods that rely on monitoring pressure variation, this approach detects the extremely weak force exerted by the released gas molecules. Verified through principle experiments, the detection limit for the present apparatus can be evaluated to be better than 1.9 × 10−12 Pa m3/s in water molecule equivalent at room temperature. The typical test results show a measurement uncertainty of less than 4%. In addition, the apparatus can monitor the fluctuation of outgassing rate with a noise level of 3 × 10−11 Pa m3/s/Hz in the mHz frequency band. In conclusion, this first-time proposed method is especially valuable for studying the outgassing rate of small-sized samples. It can be applied in the monitor of outgassing of the inertial sensor used in the space-borne GW detection during the on-ground testing and in other high vacuum demanded scientific missions.