22 December 2022 in European Journal of Pediatrics
22 November 2024 in Pediatric Drugs
23 June 2025 in Journal of Paediatrics and Child Health
24 July 2025 in Journal of Neonatal-Perinatal Medicine
Background: Prior studies on the reliability of targeted neonatal echocardiography (TNE) among extremely low gestational age neonates (ELGANs) with a patent ductus arteriosus (PDA) have been limited to evaluation of pre-defined images by a small set of study observers. The objective of this study was to investigate the interobserver reliability of comprehensive echocardiography measures of PDA size/shunt volume and ventricular performance among TNE-neonatologists in a large national network. Methods: We conducted a prospective observational study. TNEs performed for the evaluation of PDA among ELGANs were analyzed by TNE-neonatologists from the Canadian TNE Consortium. Analyses were conducted via an interactive videoconferencing platform offering full remote control to the review software. Reliability for continuous measures was evaluated using the intraclass correlation coefficient (ICC) and coefficient of variation. The kappa statistic was used to evaluate the interobserver reliability of categorical parameters. Results: Reliability was excellent among indices of PDA size and gradient (ICC≥0.91) and good-to-excellent among most indices of left ventricular (LV) size and output (ICC≥0.79, except for LV end-systolic volume and left atrium to aortic root ratio). There was substantial to near-complete agreement on PDA shunt direction and diastolic flow abnormalities in the abdominal aorta and systemic arteries (kappa ≥0.78). However, reliability for measures of LV systolic and diastolic performance was variable with ICC range 0.21–0.95, though with low coefficient of variation (<15%). Conclusions: Interobserver reliability for most TNE measures of PDA size, gradient, shunt volume, and LV dimensions and function is good-to-excellent, supporting the validity of incorporating these indices in prospective multicenter research.
18 March 2026 in American Journal of Perinatology
Early and prolonged skin-to-skin care (SSC) reduces morbidity and mortality in preterm neonates more than intermittent SSC. Extreme preterm neonates generally do not receive early prolonged SSC for several reasons, including safety concerns and parental challenges. To facilitate prolonged SSC in this population, we invented the Skincubator, a device to overcome SSC barriers. The Skincubator enables SSC, while safely securing the baby, lines, and tubes and maintaining warmth and humidity. A retractable Transfer Pad enables transfers to and from the caregiver with minimal handling, while keeping baby is safely positioned. Once on the parent, the pad is retracted to allow full SSC. The objective of this study is to assess the Transfer Pad performance and parent satisfaction from the Skincubator. An observational study performed during the learning phase of the Skincubator feasibility study. Success rates of transfer with the retractable pad and humidity within the Skincubator were recorded. Parents were provided with questionnaires to rate (on a Likert scale of 1–5) satisfaction with the safety and convenience of the Skincubator and traditional SSC (t-SSC). Twelve babies were treated in the Skincubator by 18 parents (10 mothers, 8 fathers) for 53 sessions. Two babies were invasively ventilated during Skincubator care. Average Skincubator session time was 146 ± 52 minutes. Humidity within the Skincubator was 71 ± 11%. The retractable pad transfer succeeded in 103 of 106 attempts. Parents were very satisfied with the Skincubator SSC safety and satisfied/neutral with the safety of t-SSC (p = 0.001, Wilcoxon signed-rank test. Parents were satisfied with the Skincubator SSC convenience and neutral with the convenience of t-SSC (p = 0.02). The Skincubator allows transfer to and from SSC within a warm, humidified environment. Parents were more satisfied with the safety and convenience of Skincubator SSC as compared with t-SSC. The Skincubator may support parents in performing longer hours of SSC.
9 February 2026 in Neonatology
Introduction: Neonatal jaundice is a leading cause of early post-discharge referrals. Community follow-up commonly relies on visual assessment and clinic-based evaluation, generating avoidable visits. Scalable home pathways that maintain safety are needed. We evaluated a nurse-led home pathway that integrates transcutaneous bilirubin (TcB) screening with targeted pediatric teleconsultation. Methods: A prospective before-after study was conducted within routine nurse-led home visits for eligible infants (firstborn or preterm) ≥35 weeks of gestation. A 3-month pre-intervention phase (usual visual assessment) was compared with a 9-month intervention using TcB-guided thresholds and teleconsultation via a secure digital platform. The primary analysis targeted infants who, under usual care, would be referred (“baseline-eligible”), estimating the absolute difference in referral at the home visit. Secondary outcomes were agreement between clinical cues and TcB, teleconsultation utilization, and phototherapy requirement. Results: A total of 1,236 infants were enrolled (157 pre-intervention; 1,079 intervention). Among baseline-eligible infants (n = 840), 152 (18.1%) were referred; thus, 688/840 (81.9%) potential referrals were avoided (absolute reduction 81.9%; 95% CI 79.2–84.4; NNR 1.22, 95% CI 1.19–1.26). TcB identified all infants requiring phototherapy (4/1,079; 0.4%) within 14 days. Agreement between clinical cues and TcB-defined need for follow-up was slight (weighted κ = 0.075; 95% CI 0.059–0.091). The reduction in referrals corresponded to an absolute decrease of 0.67 visits per infant. Conclusions: A nurse-led, digitally supported home pathway that integrates TcB screening and targeted teleconsultation substantially reduces unnecessary neonatal referrals, with no missed cases requiring phototherapy. This pragmatic precision-triage model is implementable within existing community services and can relieve post-discharge system burden while preserving safety.