Arun Kumar Karngala

Arun Kumar Karngala

Auto-generated profile, based on publicly available information

Arun Kumar Karngala

Eaton Research Lab, Golden, CO, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2021 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
AKArun Kumar Karngala
Arun Kumar Karngala
CSChanan Singh
Chanan Singh
This paper introduces a new framework for the reliability assessment of the distribution systems. The framework proposes three levels to include the effects of distributed generation (DG), energy storage (ES) systems connected to the distribution system and as behind the meter at the customer premises, coordination of resources, and cyber-physical systems. Methodology for level 2 reliability assessment that includes behind the meter DG and ES systems of the distribution system is proposed. A multi-state reliability model for behind the meter PV systems is developed along with the model for the ES system. The developed methodology is demonstrated on the RBTS bus 4 test distribution system with behind the meter PV and ES systems.


26 March 2025 in IEEE Electrification Magazine
Verified
Journal Article
Closed access
DKDongjoo Kim
Dongjoo Kim
AKArun Kumar Karngala
Arun Kumar Karngala
RSRanyu Shi
Ranyu Shi
LXLe Xie
Le Xie
Many regions such as Texas face escalating grid stress due to rapid population growth, industrialization, and extreme weather events. Virtual Power Plants (VPPs), aggregating distributed energy resources (DERs) such as smart thermostats, behind-the-meter photovoltaics (BTM-PV), and flexible loads, offer a scalable solution for enhancing grid flexibility and resilience. This study quantifies the peak demand reduction potential of demand-side resources in the Texas region using Monte Carlo simulations. Results indicate that widespread smart thermostat adoption could potentially reduce peak demand by up to 3.98 GW, while 10% BTM-PV penetration could potentially offset over 2 GW during peak hours. Key challenges include steep net-load ramp rates and distribution system constraints due to reverse power flow. Additionally, demand response (DR) effectiveness is highly sensitive to consumer participation, shaped by enrollment models, incentives, and communication strategies. These findings emphasize both technical and socio-economic prerequisites for effective VPP deployment and offer a possible framework for other regions targeting enhanced grid reliability and decarbonization.