Kwang Jin Lee

Kwang Jin Lee

Auto-generated profile, based on publicly available information

Kwang Jin Lee

Department of Biomedical Science and Engineering (BMSE), Institute of Integrated Technology (IIT), Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JRJongryun Roh
Jongryun Roh
HPHyeong-Jun Park
Hyeong-Jun Park
KLKwang Jin Lee
Kwang Jin Lee
JHJoonho Hyeong
Joonho Hyeong
SKSayup KIM
Sayup KIM
BLBoreom Lee
Boreom Lee
Sitting posture monitoring systems (SPMSs) help assess the posture of a seated person in real-time and improve sitting posture. To date, SPMS studies reported have required many sensors mounted on the backrest plate and seat plate of a chair. The present study, therefore, developed a system that measures a total of six sitting postures including the posture that applied a load to the backrest plate, with four load cells mounted only on the seat plate. Various machine learning algorithms were applied to the body weight ratio measured by the developed SPMS to identify the method that most accurately classified the actual sitting posture of the seated person. After classifying the sitting postures using several classifiers, average and maximum classification rates of 97.20% and 97.94%, respectively, were obtained from nine subjects with a support vector machine using the radial basis function kernel; the results obtained by this classifier showed a statistically significant difference from the results of multiple classifications using other classifiers. The proposed SPMS was able to classify six sitting postures including the posture with loading on the backrest and showed the possibility of classifying the sitting posture even though the number of sensors is reduced.

1 July 2016 in Sensors
Verified
Journal Article
Open access
PDF file
KLKwang Jin Lee
Kwang Jin Lee
BLBoreom Lee
Boreom Lee
Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR.

25 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
WSWoojoon Seok
Woojoon Seok
KLKwang Jin Lee
Kwang Jin Lee
DCDongrae Cho
Dongrae Cho
JRJongryun Roh
Jongryun Roh
SKSayup KIM
Sayup KIM
Hypertension is a chronic disease that kills 7.6 million people worldwide annually. A continuous blood pressure monitoring system is required to accurately diagnose hypertension. Here, a chair-shaped ballistocardiogram (BCG)-based blood pressure estimation system was developed with no sensors attached to users. Two experimental sessions were conducted with 30 subjects. In the first session, two-channel BCG and blood pressure data were recorded for each subject. In the second session, the two-channel BCG and blood pressure data were recorded after running on a treadmill and then resting on the newly developed system. The empirical mode decomposition algorithm was used to remove noise in the two-channel BCG, and the instantaneous phase was calculated by applying a Hilbert transform to the first intrinsic mode functions. After training a convolutional neural network regression model that predicts the systolic and diastolic blood pressures (SBP and DBP) from the two-channel BCG phase, the results of the first session (rest) and second session (recovery) were compared. The results confirmed that the proposed model accurately estimates the rapidly rising blood pressure in the recovery state. Results from the rest sessions satisfied the Association for the Advancement of Medical Instrumentation (AAMI) international standards. The standard deviation of the SBP results in the recovery session exceeded 0.7.


29 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
JKJongin Kim
Jongin Kim
DCDongrae Cho
Dongrae Cho
KLKwang Jin Lee
Kwang Jin Lee
BLBoreom Lee
Boreom Lee
In this paper, we propose a system for inferring the pinch-to-zoom gesture using surface EMG (Electromyography) signals in real time. Pinch-to-zoom, which is a common gesture in smart devices such as an iPhone or an Android phone, is used to control the size of images or web pages according to the distance between the thumb and index finger. To infer the finger motion, we recorded EMG signals obtained from the first dorsal interosseous muscle, which is highly related to the pinch-to-zoom gesture, and used a support vector machine for classification between four finger motion distances. The powers which are estimated by Welch’s method were used as feature vectors. In order to solve the multiclass classification problem, we applied a one-versus-one strategy, since a support vector machine is basically a binary classifier. As a result, our system yields 93.38% classification accuracy averaged over six subjects. The classification accuracy was estimated using 10-fold cross validation. Through our system, we expect to not only develop practical prosthetic devices but to also construct a novel user experience (UX) for smart devices.

31 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
KLKwang Jin Lee
Kwang Jin Lee
JRJongryun Roh
Jongryun Roh
DCDongrae Cho
Dongrae Cho
JHJoonho Hyeong
Joonho Hyeong
SKSayup KIM
Sayup KIM
Hypertension is a well-known chronic disease that causes complications such as cardiovascular diseases or stroke, and thus needs to be continuously managed by using a simple system for measuring blood pressure. The existing method for measuring blood pressure uses a wrapping cuff, which makes measuring difficult for patients. To address this problem, cuffless blood pressure measurement methods that detect the peak pressure via signals measured using photoplethysmogram (PPG) and electrocardiogram (ECG) sensors and use it to calculate the pulse transit time (PTT) or pulse wave velocity (PWV) have been studied. However, a drawback of these methods is that a user must be able to recognize and establish contact with the sensor. Furthermore, the peak of the PPG or ECG cannot be detected if the signal quality drops, leading to a decrease in accuracy. In this study, a chair-type system that can monitor blood pressure using polyvinylidene fluoride (PVDF) films in a nonintrusive manner to users was developed. The proposed method also uses instantaneous phase difference (IPD) instead of PTT as the feature value for estimating blood pressure. Experiments were conducted using a blood pressure estimation model created via an artificial neural network (ANN), which showed that IPD could estimate more accurate readings of blood pressure compared to PTT, thus demonstrating the possibility of a nonintrusive blood pressure monitoring system.