Li Zhang

Li Zhang

Auto-generated profile, based on publicly available information

Li Zhang

School of Physical Science and Technology, ShanghaiTech University, Shanghai, China

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 1995 in Electronics Letters
Verified
Journal Article
Closed access
JYJ. Yu
J. Yu
DHD. Huhse
D. Huhse
MSM. Schell
M. Schell
MSM. Schulze
M. Schulze
Dieter BimbergDieter Bimberg
Dieter Bimberg
IBI. Bennion
I. Bennion
A chirped Bragg grating fibre external cavity semiconductor laser is hybridly modelocked to generate light pulses with perfectly linear wavelength chirp, resulting in Fourier-transform-limited 2.5 ps pulses incorporated with subsequent chirp compensation. The setup facilitates wavelength tunability across the whole grating bandwidth (15 nm) by changing the modulation frequency.

1 September 2007 in Optics Communications
Verified
Journal Article
Closed access
VKV. Karalekas
V. Karalekas
JCJuan Diego Ania Castañon
Juan Diego Ania Castañon
José Pérez-GonzálezJosé Pérez-González
José Pérez-González
XCX. Chen
X. Chen
LZL. Zhang
L. Zhang
PHP. Harper
P. Harper

19 March 2024 in IEEE Photonics Journal
Verified
Journal Article
Open access
LZLi Zhang
Li Zhang
STShengjie Tang
Shengjie Tang
CCCheng Chen
Cheng Chen
HLHaibin Lv
Haibin Lv
XLXiaoping Liu
Xiaoping Liu
An on-chip, high-extinction-ratio transverse electric (TE) pass polarizer utilizing a silicon oxynitride (SiON) slab has been proposed and experimentally verified. The power confinement ratio of the mode field is manipulated by using a SiON slab, where most of the power of the transverse magnetic (TM) mode is transferred to the upper SiON slab and then attenuated through radiation, while the TE mode passes through with relatively low propagation loss. Experimental results show that our proposed device can achieve an extinction ratio that varies from 20.5 to 32.7 dB in the wavelength range of 790 to 870 nm, with an insertion loss of 0.6 to 1.7 dB. Potentially, this design has lower material refractive index contrast, larger minimum etching size, smaller lengths, and less stray light crosstalk, which is beneficial for systems applications such as gyroscopes.

1 January 1997
Verified
Conference Paper
Closed access
PDF file
YRY. J. Rao
Y. J. Rao
DJD. A. Jackson
D. A. Jackson
DWDavid Webb
David Webb
LZL. Zhang
L. Zhang
IBI. Bennion
I. Bennion
Measurement of the heart’s efficiency plays a key role for cardiac monitoring. Since 1970, doctors have injected patients with cold solution to measure their hearts’ blood output [1]. A flow-directed thermodilution catheter is inserted into the right atrium of the heart. The catheter allows the solution to be injected directly into the heart and enables measurement of the temperature of the blood in the pulmonary artery. By combining temperature readings with pulse rate, doctors can determine how much blood the heart pumps. Such types of catheters with conventional thermistor and thermocouple devices have been commercially available for many years and are still widely used in practice. However, as these sensors are electrically active they are not appropriate for use in a number of medical applications, in particular, in high magnetic fields associated with NMR machines. Fibreoptic sensors can overcome this problem as they are dielectric and hence virtually immune to electromagnetic interference