Sunjung Kim

Sunjung Kim

Auto-generated profile, based on publicly available information

Sunjung Kim

Department of Biomechanics, Hospital for Special Surgery, New York, NY

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MAMahsa Alimohammadi
Mahsa Alimohammadi
HMHassan Mirzabozorg
Hassan Mirzabozorg
FFFarzam Farahmand
Farzam Farahmand
SKSunjung Kim
Sunjung Kim
CBCaroline Baril
Caroline Baril
HPHeidi-Lynn Ploeg
Heidi-Lynn Ploeg

1 December 2021 in Materialia
Verified
Journal Article
Closed access
SKSunjung Kim
Sunjung Kim
ABAaron R. Bishop
Aaron R. Bishop
HPHeidi-Lynn Ploeg
Heidi-Lynn Ploeg
WRWarren E. Rose
Warren E. Rose

2 October 2025 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
Camille FM BlackmanCamille FM Blackman
Camille FM Blackman
DSDevansh Saini
Devansh Saini
SKSunjung Kim
Sunjung Kim
NZNaji Bou Zeid
Naji Bou Zeid
STStephanie L. Taiberg
Stephanie L. Taiberg
LALee Alkureishi
Lee Alkureishi
Purpose: This study evaluates whether burr holes reduce fracture risk during craniosynostosis surgery by examining their effect on stress distribution at osteotomy endpoints. Methods: Sixteen macaque calvaria samples (mean age: 8.5 years) were sectioned into 30 × 19 mm pieces. The experimental group (n=8) included burr holes at osteotomy endpoints; the control group (n=8) did not. Finite element analysis optimized osteotomy and fixture hole placement. Mechanical testing utilized an MTS® 30/G universal testing machine. Groups were compared via independent samples t test. Results: The addition of burr holes did not significantly affect load-bearing capacity or displacement of the specimens. Mean peak load was 70.85 N (SD 22.30) in the burr-hole group versus 69.73 N (SD 20.12) in the control group ( P =0.9175). Mean displacement was identical at 1.26 mm (burr-hole SD 0.27 mm; control SD 0.38 mm; P =0.9924). Fracture toughness (Kc) was also comparable between groups: burr-hole 583.1 kJ/m² (SD 165.6) versus control 584.7 kJ/m² (SD 147.9) ( P =0.9840). Conclusion: Burr holes did not significantly impact load-bearing capacity, displacement, or fracture toughness in macaque calvarial bone, contrasting with isotropic materials (eg, steel) where stress relievers reduce fracture risk. Future research should explore alternative stress-relief osteotomy designs to minimize intraoperative fracture risks.

4 March 2026 in Foot & Ankle International
Verified
Journal Article
Closed access
JPJoaquin Palma
Joaquin Palma
JHJeffrey W. Hoffman
Jeffrey W. Hoffman
THThos Harnroongroj
Thos Harnroongroj
SKSunjung Kim
Sunjung Kim
JHJensen Henry
Jensen Henry
CDConstantine A. Demetracopoulos
Constantine A. Demetracopoulos
Background: The availability of total ankle arthroplasty (TAA) systems with varying designs of talar condylar geometry has increased. However, it remains unclear how these features influence the motion of the ankle and hindfoot joints. This study assessed the ankle and hindfoot kinematics using a contemporary TAA system with a symmetric bicondylar talar component design. Methods: TAA was performed in eleven mid-tibia specimens. A 6–degree-of-freedom robot sequentially simulated the stance phase for the intact and post-TAA conditions. The kinematics and range of motion (ROM) of the ankle, subtalar, and talonavicular joints were calculated and compared between conditions. Results: The ankle demonstrated decreased dorsiflexion by 4.0 degrees ( P = .041) and increased inversion by 1.5 degrees ( P = .04) during early stance. The talonavicular joint was significantly more everted by 3.5 degrees during a portion of late stance ( P = .016). There were no significant differences between conditions in the subtalar joint. The ankle ROM in the transverse plane increased 1.9 degrees post-TAA ( P = .025), but no significant changes were observed in the subtalar or talonavicular joints. Conclusion: In this cadaveric stance‑phase simulation, ankle and hindfoot kinematics and ROM were modestly altered after TAA. Therefore, a TAA system with a symmetric talar condylar design may closely replicate native ankle and hindfoot joint motion. Clinical Relevance: Implant design may influence joint kinematics; in this cadaveric model, a symmetric bicondylar talar component showed smaller transverse‑plane ROM increases than those previously reported for one asymmetric design tested under similar conditions.

29 October 2026 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
JHJensen K. Henry
Jensen K. Henry
JHJeffrey Hoffman
Jeffrey Hoffman
RVRicardo Villar
Ricardo Villar
KLKira Lu
Kira Lu
SKSunjung Kim
Sunjung Kim
CDConstantine Demetracopoulos
Constantine Demetracopoulos
Background: Total ankle replacements (TARs) have a risk of early mechanical failure. Clinical studies have shown that implants with more robust tibial fixation—i.e., stemmed designs—have a lower early mechanical failure risk. We aimed to compare the micromotion between 2 tibial components with different fixation features, using a cadaveric robotic gait simulator. We hypothesized that more robust fixation accommodates loads more effectively, resulting in less micromotion at the bone-implant interface for stemmed tibial implants when compared to low-profile tibial implants. Methods: Specimens from 10 cadaveric matched pairs (from 6 men and 4 women, age: 48 ± 11 years) were implanted with either a low-profile or stemmed TAR. Post-TAR, gait was simulated using a validated 6-degrees-of-freedom robot. A digital image correlation camera system captured the relative motion between the tibial bone and the implant via surface markers. Implant micromotion was calculated by performing rigid-body transformations on segmented geometries of the tibia and implant derived from computed tomography imaging. Peak and mean micromotion were defined as the maximum and mean nodal displacement, respectively, on the implant surface across all time points in stance. Wilcoxon signed-rank tests compared micromotion of stemmed and low-profile implants between matched pairs. Results: On average, peak and mean micromotion values were greater for low-profile implants by 150 µm (95% confidence interval [CI]: 98 to 203 µm) and 30 µm (95% CI: 9 to 52 µm), respectively, compared with the matched stemmed implants (p < 0.001 for both). Peak micromotion of low-profile implants typically occurred at the posterior aspect of the implant. In contrast, stemmed implants demonstrated a more evenly distributed pattern with peak micromotion located at the tip of the stem. Conclusions: This study identified significantly greater time-zero micromotion of low-profile tibial implants compared with stemmed implants. The micromotion distribution suggests that the stemmed implants were further compressed into bone, whereas the low-profile implants demonstrated a rocking motion. Our data support the notion that early mechanical failures of low-profile tibial implants may be due to excessive early micromotion. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.