15 February 2023 in Mechanics of Advanced Materials and Structures
In aspects of its simple configuration and tunability, piezoelectric-based metasurface has benefited over its mechanical counterpart in adaptive wavefront manipulation. By tuning the circuitry elements in the shunting circuits properly, the equivalent material properties of the metasurface can be modified to attain a complete phase shift and to maintain high transmission at desired working frequencies. In this paper, a piezoelectric-based elastic metasurface with hybrid shunting circuits ( – – shunts) are proposed to adaptively control the propagation of flexural waves. Through tuning of negative capacitance and inductance simultaneously, the proposed elastic metasurface can cover a phase shift ranging from while having a high transmission ( 0.7). It is discovered that any similar metasurface structural design with solely single shunting circuit presently available could not achieve the same results as the proposed elastic metasurface. In addition, analytical modeling based on equivalent Young’s modulus is developed and a finite element model is built to study the transmission and phase shift of the proposed metasurface. It is demonstrated numerically that the proposed piezoelectric-based elastic metasurface is capable of performing switchable functionalities, such as wave refraction and focusing, at different working frequencies (3500 Hz, 5000 Hz, etc.). Graphical Abstract
13 March 2025 in Nano Energy
1 May 2020 in IOP Conference Series: Earth and Environmental Science
In Malaysia, issue to attain durable concrete structures has risen due to shortage of skilled labours. Besides pollution due to construction activities, safety and health of the workers is also a major concern. Self-compacting concrete is able to overcome the problems through its execution. Moreover, properties of SCC can be further improved via incorporation with other materials. Thus, this study was conducted to investigate the strengths and water absorption of SCC containing metakaolin (MK) and nylon fiber (NF) besides determining the effects of MK and NF in SCC. Four mixes (100%C, 95%C 5%MK, 100%C 0.5%NF, 95%C 5%MK 0.5%NF) were being carried out with w/c ratio 0.4 and 1.5% super-plasticizer (SP). Fresh concrete were tested with slump flow, T500 and segregation resistance test whereas hardened concrete were tested with compressive, tensile and flexural strength test. The results of fresh SCC were consistent as all mixes mostly falls in the same class for each respective test. Based on compressive strength test, all mix proportions were able to reach at least 80% of targeted strength, 50MPa. SCC (95%C 5%MK) had the highest compressive, split tensile and flexural strength. While SCC (95%C 5%MK0.5 %NF had better testing results compare to 100%C 0.5%NF.
2 February 2026 in Engineering Structures
29 April 2026 in Engineering Structures
30 September 2026 in Thin-Walled Structures