Julia Koch

Julia Koch

Auto-generated profile, based on publicly available information

Julia Koch

Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering, University of Freiburg, Germany

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2013 in Bioresource Technology
Verified
Journal Article
Closed access
EKElena Kipf
Elena Kipf
JKJulia Koch
Julia Koch
BGBettina Geiger
Bettina Geiger
JEJohannes Erben
Johannes Erben
KRKatrin Richter
Katrin Richter
SKSven Kerzenmacher
Sven Kerzenmacher

29 October 2019 in Journal of Neural Engineering
Verified
Journal Article
Open access
JKJulia Koch
Julia Koch
MSMartin Schuettler
Martin Schuettler
CPCristian Pasluosta
Cristian Pasluosta
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz
Technological advances in electrically active implantable devices have increased the complexity of hardware design. In particular, the increasing number of stimulation and recording channels requires innovative approaches for connectors that interface electrodes with the implant circuitry. Objective. This work aims to provide a common theoretical ground for implantable connector development with a focus on neural applications. Approach. Aspects and experiences from several disciplines are compiled from an engineering perspective to discuss the state of the art of connector solutions. Whenever available, we also present general design guidelines. Main results. Degradation mechanisms, material stability and design rules in terms of biocompatibility and biostability are introduced. Considering contact physics, we address the design and characterization of the contact zone and review contaminants, wear and contact degradation. For high-channel counts and body-like environments, insulation can be even more crucial than the electrical connection itself. Therefore, we also introduce the requirements for electrical insulation to prevent signal loss and distortion and discuss its impact on the practical implementation. Significance. A final review is dedicated to the state of the art connector concepts, their mechanical setup, electrical performance and the interface to other implant components. We conclude with an outlook for possible approaches for the future generations of implants.

1 August 2015
Verified
Conference Paper
Closed access
JKJulia Koch
Julia Koch
JOJuan S. Ordonez
Juan S. Ordonez
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz
MSMartin Schuettler
Martin Schuettler
Further development of active implantable medical devices (AIMDs) coming along with higher channel counts and improved maintainability raises the requirements for implantable connectors in such systems. We developed a concept for an implantable multichannel connector. Contact pads manufactured by laser-structuring that are embedded into a silicone substrate serve as contact partners. Processing features specific to two laser technologies were exploited not only to cut the materials but also to 3D-shape the surfaces of the contact pads. First tests for the long-term behavior show stable contact and isolation properties during 6 weeks of soaking at elevated temperature.

1 July 2017 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
Verified
Conference Paper
Closed access
JKJulia Koch
Julia Koch
MSMartin Schuettler
Martin Schuettler
Thomas StieglitzThomas Stieglitz
Thomas Stieglitz
Detachable high-channel electrical connections pose a bottleneck on the path to active implants with higher numbers of electrode contacts and miniaturized geometries. Not only low-resistance, reproducible and reliable contacts have to be realized but also seals that ensure electrical insulation in the harsh body environment. Using planar contact arrangements one can resort to laser microprocessing leading to minimal size connectors. However, this poses the need to carefully design the topographies within the contact zone. In this study, we assess different methods to design the topography of planar contact pad arrays. Using topographical analysis and evaluation of electrical functionality, influential mechanisms were identified and two functional ones have been selected.