Raghav Gupta

Raghav Gupta

Auto-generated profile, based on publicly available information

Raghav Gupta

Neurosurgical Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KAKsenia Aaron
Ksenia Aaron
JVJohn Vaughan
John Vaughan
RGRaghav Gupta
Raghav Gupta
NANoor-E-Seher Ali
Noor-E-Seher Ali
ABAlicia H. Beth
Alicia H. Beth
YVYona Vaisbuch
Yona Vaisbuch
Objective: Lack of ergonomic training and poor ergonomic habits during the operation leads to musculoskeletal pain and affects the surgeon’s life outside of work. The objective of the study was to evaluate the severity of ergonomic hazards in the surgical profession across a wide range of surgical subspecialties. We conducted intraoperative observations using Rapid Entire Body Assessment (REBA) score system to identify ergonomic hazards. Additionally, each of the ten surgical subspecialty departments were sent an optional 14 question survey which evaluated ergonomic practice, environmental infrastructure, and prior ergonomic training or education. A total of 91 surgeons received intraoperative observation and were evaluated on the REBA scale with a minimum score of 0 (low ergonomic risk <3) and a maximum score of 10 (high ergonomic risk 8–10). And a total of 389 surgeons received the survey and 167 (43%) surgeons responded. Of the respondents, 69.7% reported suffering from musculoskeletal pain. Furthermore, 54.9% of the surgeons reported suffering from the highest level of pain when standing during surgery, while only 14.4% experienced pain when sitting. Importantly, 47.7% stated the pain impacted their work, while 59.5% reported pain affecting quality of life outside of work. Only 23.8% of surgeons had any prior ergonomic education. Both our subjective and objective data suggest that pain and disability induced by poor ergonomics are widespread among the surgical community and confirm that surgeons rarely receive ergonomic training. Intraoperative observational findings identified that the majority of observed surgeons displayed poor posture, particularly a poor cervical angle and use of ergonomic setups, both of which increase ergonomic risk hazards. This data supports the need for a comprehensive ergonomic interventional program for the surgical team and offers potential targets for future intervention.

14 September 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
NANimer Adeeb
Nimer Adeeb
JMJ.M. Moore
J.M. Moore
MWM. Wirtz
M. Wirtz
CGC.J. Griessenauer
C.J. Griessenauer
PFP.M. Foreman
P.M. Foreman
COChristopher S. Ogilvy
Christopher S. Ogilvy
BACKGROUND AND PURPOSE: Flow diversion with the Pipeline Embolization Device (PED) for the treatment of intracranial aneurysms is associated with a high rate of aneurysm occlusion. However, clinical and radiographic predictors of incomplete aneurysm occlusion are poorly defined. In this study, predictors of incomplete occlusion at last angiographic follow-up after PED treatment were assessed. MATERIALS AND METHODS: A retrospective analysis of consecutive aneurysms treated with the PED between 2009 and 2016, at 3 academic institutions in the United States, was performed. Cases with angiographic follow-up were selected to evaluate factors predictive of incomplete aneurysm occlusion at last follow-up. RESULTS: We identified 465 aneurysms treated with the PED; 380 (81.7%) aneurysms (329 procedures; median age, 58 years; female/male ratio, 4.8:1) had angiographic follow-up, and were included. Complete occlusion (100%) was achieved in 78.2% of aneurysms. Near-complete (90%–99%) and partial (<90%) occlusion were collectively achieved in 21.8% of aneurysms and defined as incomplete occlusion. Of aneurysms followed for at least 12 months (211 of 380), complete occlusion was achieved in 83.9%. Older age (older than 70 years), nonsmoking status, aneurysm location within the posterior communicating artery or posterior circulation, greater aneurysm maximal diameter (≥21 mm), and shorter follow-up time (<12 months) were significantly associated with incomplete aneurysm occlusion at last angiographic follow-up on univariable analysis. However, on multivariable logistic regression, only age, smoking status, and duration of follow-up were independently associated with occlusion status. CONCLUSIONS: Complete occlusion following PED treatment of intracranial aneurysms can be influenced by several factors related to the patient, aneurysm, and treatment. Of these factors, older age (older than 70 years) and nonsmoking status were independent predictors of incomplete occlusion. While the physiologic explanation for these findings remains unknown, identification of factors predictive of incomplete aneurysm occlusion following PED placement can assist in patient selection and counseling and might provide insight into the biologic factors affecting endothelialization.

1 February 2018 in World Neurosurgery
Verified
Journal Article
Closed access
RTRanjit Thomas
Ranjit Thomas
RGRaghav Gupta
Raghav Gupta
CGChristoph J. Griessenauer
Christoph J. Griessenauer
JMJustin M. Moore
Justin M. Moore
NANimer Adeeb
Nimer Adeeb
ATAjith J. Thomas
Ajith J. Thomas

1 December 2016 in World Neurosurgery
Verified
Journal Article
Closed access
RGRaghav Gupta
Raghav Gupta
JMJustin M. Moore
Justin M. Moore
CGChristoph J. Griessenauer
Christoph J. Griessenauer
NANimer Adeeb
Nimer Adeeb
APApar S. Patel
Apar S. Patel
COChristopher S. Ogilvy
Christopher S. Ogilvy

7 June 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
NANimer Adeeb
Nimer Adeeb
CGC.J. Griessenauer
C.J. Griessenauer
Adam DmytriwAdam Dmytriw
Adam Dmytriw
HSH. Shallwani
H. Shallwani
RGR. Gupta
R. Gupta
ATA.J. Thomas
A.J. Thomas
BACKGROUND AND PURPOSE: Flow diversion with the Pipeline Embolization Device is increasingly used for endovascular treatment of intracranial aneurysms due to high reported obliteration rates and low associated morbidity. While obliteration of covered branches in the anterior circulation is generally asymptomatic, this has not been studied within the posterior circulation. The aim of this study was to evaluate the association between branch coverage and occlusion, as well as associated ischemic events in a cohort of patients with posterior circulation aneurysms treated with the Pipeline Embolization Device. MATERIALS AND METHODS: A retrospective review of prospectively maintained databases at 8 academic institutions from 2009 to 2016 was performed to identify patients with posterior circulation aneurysms treated with the Pipeline Embolization Device. Branch coverage following placement was evaluated, including the posterior inferior cerebellar artery, anterior inferior cerebellar artery, superior cerebellar artery, and posterior cerebral artery. If the Pipeline Embolization Device crossed the ostia of the contralateral vertebral artery, its long-term patency was assessed as well. RESULTS: A cohort of 129 consecutive patients underwent treatment of 131 posterior circulation aneurysms with the Pipeline Embolization Device. Adjunctive coiling was used in 40 (31.0%) procedures. One or more branches were covered in 103 (79.8%) procedures. At a median follow-up of 11 months, 11% were occluded, most frequently the vertebral artery (34.8%). Branch obliteration was most common among asymptomatic aneurysms (P < .001). Ischemic complications occurred in 29 (22.5%) procedures. On multivariable analysis, there was no significant difference in ischemic complications in cases in which a branch was covered (P = .24) or occluded (P = .16). CONCLUSIONS: There was a low occlusion incidence in end arteries following branch coverage at last follow-up. The incidence was higher in the posterior cerebral artery and vertebral artery where collateral supply is high. Branch occlusion was not associated with a significant increase in ischemic complications.

10 November 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
CGC.J. Griessenauer
C.J. Griessenauer
RGR. Gupta
R. Gupta
SSSiyu Shi
Siyu Shi
AAA. Alturki
A. Alturki
RMRouzbeh Motiei-Langroudi
Rouzbeh Motiei-Langroudi
ATA.J. Thomas
A.J. Thomas
BACKGROUND AND PURPOSE: Flow diversion with the Pipeline Embolization Device has emerged as an attractive treatment for cerebral aneurysms. Processes involved in aneurysm occlusion include changes in intra-aneurysmal hemodynamics and endothelialization of the device. Here, we call attention to a radiographic sign not previously reported that is detected in incompletely occluded aneurysms after treatment with the Pipeline Embolization Device at angiographic follow-up and referred to as the “collar sign.” MATERIALS AND METHODS: A retrospective review of all patients who underwent placement of a Pipeline Embolization Device for cerebral aneurysms between January 2014 and May 2016 was performed. All aneurysms found to show the collar sign at follow-up were included. Optical coherence tomography was performed in 1 case. RESULTS: One hundred thirty-five aneurysms were treated in 115 patients. At angiographic follow-up, 17 (10.7%) aneurysms were found to be incompletely occluded. Ten (58.8%) of these aneurysms (average diameter, 7.9 ± 5.0 mm) were found to have the collar sign at angiographic follow-up (average, 5.5 ± 1.0 months). Four (40.0%) of the aneurysms underwent a second angiographic follow-up (average, 11.0 ± 0.9 months) after treatment, and again were incompletely occluded and showing the collar sign. Two patients underwent retreatment with a second Pipeline Embolization Device. Optical coherence tomography showed great variability of endothelialization at the proximal end of the Pipeline Embolization Device. CONCLUSIONS: The collar sign appears to be indicative of endothelialization, but continued blood flow into the aneurysm. This is unusual given the processes involved in aneurysm occlusion after placement of the Pipeline Embolization Device and has not been previously reported.