Background. Multi-locus TMS (mTMS) enables precise electronic control of brain stimulation targeting, eliminating the need for physical coil movement. However, with a small number of coils, the stimulation area is constrained, and manual handling of the coil array is cumbersome. Combining electronic mTMS targeting with robotics enables automated, user-independent, and precise brain stimulation protocols. Objective. To characterize an open-source electronic–robotic mTMS platform for rapid and accurate brain stimulation targeting. Methods. We developed an automated robotic mTMS positioning platform. We used a 5-coil mTMS device coupled to a collaborative robot. The stimulation targeting accuracy of the system was quantified with a TMS characterizer that measures the TMS-induced electric field (E-field) on a model of a spherical cortex. The induced E-field distortion generated by robot coupling was evaluated for each coil. We compared the repositioning accuracy of robotic–electronic system to the conventional manual positioning. Results. Our collaborative-robot-based system offers submillimeter precision and autonomy in positioning mTMS coil sets. The electronic–robotic mTMS platform was approximately 1.8 mm and 1.0° more accurate than the conventional manual positioning. Integrating robotics and mTMS automates brain stimulation procedures, resulting in minimal reliance on user expertise and subjective analysis. Conclusion. Our open-source platform combining rapid mTMS targeting with robotic precision enhances the safety and reproducibility of TMS, enabling more efficient and reliable outcomes than previous techniques.
Background Multi-locus TMS (mTMS) enables precise electronic control of brain stimulation targeting, eliminating the need for physical coil movement. However, with a small number of coils, the stimulation area is constrained, and manually handling the coil array is cumbersome. Combining electronic mTMS targeting with robotics will enable automated, user-independent, and precise brain stimulation protocols. Objective Characterizing an open-source electronic–robotic mTMS platform for rapid and accurate brain stimulation targeting. Methods We developed an automated robotic mTMS positioning platform. The accuracy of the system was quantified with a TMS characterizer that measures the TMS-induced electric field on a spherical cortex model. We used a 5-coil mTMS device equipped with a set of five coils coupled to a collaborative robot. The induced electric-field distortion generated by robot coupling was evaluated for each coil. We compared the accuracy of robotic–electronic targeting by repositioning the mTMS coil set with the robotic and the conventional manual positioning. Results Our collaborative robot-based system offers submillimeter precision and autonomy in positioning mTMS coil sets. The electronic–robotic mTMS platform was approximately 1.8 mm and 1.0° more accurate than the conventional manual positioning. Integrating robotics and mTMS automates brain stimulation procedures, resulting in minimal reliance on user expertise and subjective analysis. Conclusion Our open-source platform combining rapid mTMS targeting with robotic precision enhances the safety and reproducibility of brain stimulation techniques, enabling more efficient and reliable outcomes than previous techniques.
15 March 2025 in Brazilian Journal of Motor Behavior
Background: Transcranial Magnetic Stimulation (TMS) has emerged as a powerful tool for investigating motor behavior, primarily by analyzing the motor evoked potential (MEP) properties. Aim: This tutorial provides an integrated framework for understanding TMS from the neurobiomechanics and motor control perspectives. Method: We describe the role of surface electromyography (sEMG) in recording MEPs alongside protocols for electrode placement, the influence of whole and body parts in corticospinal excitability, principles of TMS instrumentation, neuronavigation techniques, robotics for precise TMS coil positioning, and TMS combined with electroencephalography (EEG). Conclusion: By integrating foundational concepts and practical guidelines on TMS applications – including MEP analysis, EEG integration, and neuronavigation – this tutorial provides researchers with a comprehensive framework for designing and interpreting studies effectively, thereby advancing the knowledge of motor control and biomechanics.
Background: Identifying the stimulation brain target is fundamental for transcranial magnetic stimulation (TMS). Currently, this process is time-consuming and heavily dependent on the operator’s expertise. Objective: This study evaluated a deep learning–based approach to structural brain connectivity for improving stimulation site prediction and real-time cortical excitability mapping during neuronavigation. Results: Tractography-derived connectivity features and distal myographic responses were used to train four neural network models across five subjects. Neural network inputs were incrementally varied using either tractography alone, coil coordinates alone, or hybrid combinations of both using different concatenation regimes. The best performance was observed in two subjects out of 5, where hybrid models integrating coil coordinates and fiber information achieved higher F1 scores and accuracy. Conclusion: Despite these promising results, substantial inter-subject variability was observed. This approach may also be applied to other brain regions to investigate connectivity, and the use of machine learning could be extended to functional domains beyond the motor cortex, including sensory and cognitive areas.