Hannah Lee

Hannah Lee

Auto-generated profile, based on publicly available information

Hannah Lee

UT MD Anderson Cancer Center, Houston, TX

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in Journal of Controlled Release
Verified
Journal Article
Closed access
HLHannah J. Lee
Hannah J. Lee
YLYang Liu
Yang Liu
JZJun Zhao
Jun Zhao
MZMin Zhou
Min Zhou
RBRichard R. Bouchard
Richard R. Bouchard
MMMarites Melancon
Marites Melancon

1 December 2017 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
HLHannah J. Lee
Hannah J. Lee
YRYvonne Roed
Yvonne Roed
SVSara Venkataraman
Sara Venkataraman
MCMitchell Carroll
Mitchell Carroll
GIGeoffrey S. Ibbott
Geoffrey S. Ibbott

1 February 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
HLHannah Jungeun Lee
Hannah Jungeun Lee
MKMo Kadbi
Mo Kadbi
GBGary Bosco
Gary Bosco
GIGeoffrey S Ibbott
Geoffrey S Ibbott
The integration of magnetic resonance imaging (MRI) with linear accelerators (linac) has enabled the use of 3D MR-visible gel dosimeters for real-time verification of volumetric dose distributions. Several iron-based radiochromic 3D gels were created in-house then imaged and irradiated in a pre-clinical 1.5 T–7 MV MR-Linac. MR images were acquired using a range of balanced-fast field echo (b-FFE) sequences during irradiation to assess the contrast and dose response in irradiated regions and to minimize the presence of MR artifacts. Out of four radiochromic 3D gel formulations, the FOX 3D gel was found to provide superior MR contrast in the irradiated regions. The FOX gels responded linearly with respect to real-time dose and the signal remained stable post-irradiation for at least 20 min. The response of the FOX gel also was found to be unaffected by the radiofrequency and gradient fields created by the b-FFE sequence during irradiation. A reusable version of the FOX gel was used for b-FFE sequence optimization to reduce artifacts by increasing the number of averages at the expense of temporal resolution. Regardless of the real-time MR sequence used, the FOX 3D gels responded linearly to dose with minimal magnetic field effects due to the strong 1.5 T field or gradient fields present during imaging. These gels can easily be made in-house using non-reusable and reusable formulations depending on the needs of the clinic, and the results of this study encourage further applications of 3D gels for MR-IGRT applications.

1 October 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
BMBrigid A McDonald
Brigid A McDonald
HLHannah Jungeun Lee
Hannah Jungeun Lee
GIGeoffrey S Ibbott
Geoffrey S Ibbott
Radiation therapy in the presence of a strong magnetic field is known to cause regions of enhanced and reduced dose at interfaces of materials with varying densities, in a phenomenon known as the electron return effect (ERE). In this study, a novel low-density gel dosimeter was developed to simulate lung tissue and was used to measure the ERE at the lung-soft tissue interface. Low-density gel dosimeters were developed with Fricke xylenol orange gelatin (FXG) and ferrous oxide xylenol orange (FOX) gels mixed with polystyrene foam beads of various sizes. The gels were characterized based on CT number, MR signal intensity, and uniformity. All low-density gels had CT numbers roughly equivalent to lung tissue. The optimal lung-equivalent gel formulation was determined to be FXG with <1 mm polystyrene beads due to the higher signal intensity of FXG compared to FOX and the higher uniformity with the small beads. Dose response curves were generated for the optimal low-density gel and conventional FXG. The change in spin-lattice relaxation rate (R1) before and after irradiation was linear with dose for both gels. Next, phantoms consisting of concentric cylinders with low-density and conventional FXG were created to simulate the lung-soft tissue interface. The phantoms were irradiated in a conventional linear accelerator (linac) and in a linac combined with a 1.5 T magnetic resonance imaging (MRI) unit (MR-linac) to measure the effects of the magnetic field on the dose distribution. Hot and cold spots were observed in the dose distribution at the boundaries between the gels for the phantom irradiated in the MR-linac but not the conventional linac, consistent with the ERE.

1 January 2016 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
GIGeoffrey S. Ibbott
Geoffrey S. Ibbott
YRYvonne Roed
Yvonne Roed
HLHannah Lee
Hannah Lee
MAMamdooh Alqathami
Mamdooh Alqathami
JWJihong Wang
Jihong Wang
Anton BlencoweAnton Blencowe
Anton Blencowe
Magnetic resonance-guided radiation therapy (MRgRT) benefits from performing treatment response assessments at the beginning and end of treatment and also during the treatment itself allowing for more normal tissue sparing and better tumor conformality. Gel dosimeters have been shown to demonstrate 3D dose distributions from conventional treatment units. This qualitative study assessed the value of gel dosimetry to measure volumetric dose distributions delivered by an MR-linac (MRL) while using the MR component for readout. Polymer gels in custom-designed glass cylinders of 5 cm diameter and 4 cm height were obtained from MGS Research Inc. (Madison, CT). In addition, Fricke-type dosimeters were prepared in-house with 0.05 mM xylenol orange. For this preliminary study, the dosimeters were irradiated in air, with a part of each dosimeter outside the treatment field to act as a reference. MR imaging was performed with the MRL to observe the change in paramagnetic properties pre and post irradiation using a T2 sequence for polymer gels and a T1-weighted sequence for Fricke gels. MRI during irradiation was done in the MRL using a fast sequence of TR = 5 ms and TE = 1.7 ms. Spin-spin relaxation rate (R2) maps were generated from the polymer gel images and line profiles across the penumbra were analyzed. R2 has previously been shown to be proportional to absorbed dose. When Fricke dosimeters are exposed to ionizing radiation, ferrous ions are oxidized to ferric ions. The paramagnetic spin changes, which are dependent on the concentrations of ferrous and ferric ion species, were observable on T1-weighted images due to changes in the spin-lattice relaxation rate (R1 = 1/T1). We observed a mean increase in pixel value of 53% from un-irradiated to irradiated regions of about 20 Gy. The increase in pixel value and corresponding dose was visible during irradiation using a fast MR sequence. The polymer gels also responded quickly. At 5 minutes after irradiation, the line profiles on the R2 map through the penumbra region showed the fall-off of the radiation field in both dosimeters. 20 hours after irradiation the polymerization of the gel was presumably completed. The overall signal was both higher on the R2 gray scale maps and more pronounced on the R2 color maps. The line profiles across the penumbra regions exhibited a similar trend for both field edges compared to the profiles at 5 minutes post-irradiation. Over the time frame tested, the dosimeter appears stable. These qualitative results indicate that gel dosimetry offers a promising means of measuring relative volumetric dose distributions delivered by an MR-Linac.

7 June 2016 in Medical Physics
Verified
Journal Article
Closed access
PDF file
HLH Lee
H Lee
MAM Alqathami
M Alqathami
MKM Kadbi
M Kadbi
JWJ Wang
J Wang
Anton BlencoweAnton Blencowe
Anton Blencowe
GIG Ibbott
G Ibbott