Kaoru Sato

Kaoru Sato

Auto-generated profile, based on publicly available information

Kaoru Sato

Affiliation Nuclear Science and Engineering Center, Japan Atomic Energy Agency, Tokai-mura, Ibaraki-ken, Japan

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2006 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
KSK. Sato
K. Sato
HNH. Noguchi
H. Noguchi
YEY. Emoto
Y. Emoto
SKS. Koga
S. Koga
KSK. Saito
K. Saito
A Japanese adult male voxel (volume pixel) phantom (hereinafter referred to as the JM phantom) was constructed on the basis of CT images of a healthy Japanese adult male volunteer. Body characteristics of the JM phantom were compared with those of a voxelised MIRD5 type phantom and a Japanese adult male voxel phantom which was previously developed. The voxel size of the JM phantom is 0.98 × 0.98 × 1 mm3. The shapes of the organs of the JM phantom, even for small or complicated organs, such as thyroid and stomach, are more realistically reproduced as compared with the previous Japanese voxel phantom (voxel size: 0.98 × 0.98 × 10 mm3). Photon self-absorbed fractions (self-AFs) for brain, kidneys, spleen, pancreas, thyroid and urinary bladder wall of JM were evaluated and were compared with those of the other phantoms. In consequence, it was suggested that the mass, shape and thickness of organs are important factors for the determination of self-AFs.

18 April 2011 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
NBNobuhiko Ban
Nobuhiko Ban
FTFumiaki Takahashi
Fumiaki Takahashi
KOKoji Ono
Koji Ono
THTakayuki Hasegawa
Takayuki Hasegawa
TYTakayasu Yoshitake
Takayasu Yoshitake
MKMichiaki Kai
Michiaki Kai
A web-based dose computation system, WAZA-ARI, is being developed for patients undergoing X-ray CT examinations. The system is implemented in Java on a Linux server running Apache Tomcat. Users choose scanning options and input parameters via a web browser over the Internet. Dose coefficients, which were calculated in a Japanese adult male phantom (JM phantom) are called upon user request and are summed over the scan range specified by the user to estimate a normalised dose. Tissue doses are finally computed based on the radiographic exposure (mA s) and the pitch factor. While dose coefficients are currently available only for limited CT scanner models, the system has achieved a high degree of flexibility and scalability without the use of commercial software.

26 May 2022 in Annals of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MIMasanobu Ibaraki
Masanobu Ibaraki
KMKeisuke Matsubara
Keisuke Matsubara
YSYuki Shinohara
Yuki Shinohara
MSMiho Shidahara
Miho Shidahara
KSKaoru Sato
Kaoru Sato
TKToshibumi Kinoshita
Toshibumi Kinoshita
Objective: In quantitative positron emission tomography (PET) of the brain, partial volume effect due mainly to the finite spatial resolution of the PET scanner (> 3 mm full width at half maximum [FWHM]) is a primary source of error in the measurement of tracer uptake, especially in small structures such as the cerebral cortex (typically < 3 mm thickness). The aim of this study was to evaluate the partial volume correction (PVC) performance of point spread function-incorporated reconstruction (PSF reconstruction) in combination with the latest digital PET scanner. This evaluation was performed through direct comparisons with magnetic resonance imaging (MR)-based PVC (used as a reference method) in a human brain study. Methods: Ten healthy subjects underwent brain 18F-FDG PET (30-min acquisition) on a digital PET/CT system (Siemens Biograph Vision, 3.5-mm FWHM scanner resolution at the center of the field of view) and anatomical T1-weighted MR imaging for MR-based PVC. PSF reconstruction was applied with a wide range of iterations (4 to 256; 5 subsets). FDG uptake in the cerebral cortex was evaluated using the standardized uptake value ratio (SUVR) and compared between PSF reconstruction and MR-based PVC. Results: Cortical structures were visualized by PSF reconstruction with several tens of iterations and were anatomically well matched with the MR-derived cortical segments. Higher numbers of iterations resulted in higher cortical SUVRs, which approached those of MR-based PVC (1.76), although even with the maximum number of iterations they were still smaller by 16% (1.47), corresponding to approximately 1.5-mm FWHM of the effective spatial resolution. Conclusion: With the latest digital PET scanner, PSF reconstruction can be used as a PVC technique in brain PET, albeit with suboptimal resolution recovery. A relative advantage of PSF reconstruction is that it can be applied not only to cerebral cortical regions, but also to various small structures such as small brain nuclei that are hardly visualized on anatomical T1-weighted imaging, and thus hardly recovered by MR-based PVC.

13 October 2010 in Journal of Microscopy
Verified
Journal Article
Closed access
PDF file
HNH. Nakamichi
H. Nakamichi
KYK. Yamada
K. Yamada
KSK. Sato
K. Sato

6 June 2007 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
KSK. Sato
K. Sato
HNH. Noguchi
H. Noguchi
AEA. Endo
A. Endo
YEY. Emoto
Y. Emoto
SKS. Koga
S. Koga
KSK. Saito
K. Saito
A Japanese voxel phantom in upright posture, JM2, has been developed on the basis of CT images of a healthy Japanese adult male. Body characteristics of JM2 were compared with those of the supine voxel phantom, JM, previously developed using CT images of the same person. Differences were found in the shapes of the spine and lower abdomen and the locations of several organs such as kidneys, liver and stomach between the two phantoms. Specific absorbed fractions (SAFs) for 24 target and 11 sources organs were calculated for monoenergetic photon ranging from 0.01 to 4 MeV. It was found that the SAFs for the kidneys as source organ and the lower large intestine wall as target organ in JM2 were significantly higher than those in JM for all photon energies. The differences of the SAFs between the two phantoms were attributed to the differences in the organ distance and organ geometry depending on the posture.

1 January 1996 in Tetsu-to-Hagane
Verified
Journal Article
Open access
PDF file
NINobuyuki Ishikawa
Nobuyuki Ishikawa
TSTetsuo Shiraga
Tetsuo Shiraga
KSKaoru Sato
Kaoru Sato
MIMoriyuki Ishiguro
Moriyuki Ishiguro
HKHitoshi Kabasawa
Hitoshi Kabasawa
YKYoshihiro Kuwahara
Yoshihiro Kuwahara