I. G Kyrysov

I. G Kyrysov

Auto-generated profile, based on publicly available information

I. G Kyrysov

V. N. Karazin Kharkiv National University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2025 in Eastern-European Journal of Enterprise Technologies
Verified
Journal Article
Open access
PDF file
PBPavlo Budanov
Pavlo Budanov
KBKostiantyn Brovko
Kostiantyn Brovko
VMVyacheslav Melnikov
Vyacheslav Melnikov
MYMykola Yakymchuk
Mykola Yakymchuk
VKVolodymyr Kononov
Volodymyr Kononov
EKEduard Khomiak
Eduard Khomiak
This study's object is the technological process that occurs at the power unit of a nuclear power plant, which is considered as a complex technical system with a multi-level hierarchical structure of functional subsystems. This paper addresses the task to improve the efficiency of modeling, monitoring, and controlling the technological process at a nuclear power plant as a complex technical system with a multi-level hierarchical structure. A new approach to modeling the modes of a nuclear power plant based on system-cluster theory has been proposed. A cluster structure with key subclusters has been built: power control, protection, heat carrier adjustment, and emergency shutdown. Mathematical models have been constructed that take into account physical processes and logical-dynamic behavior of the monitoring and control system. A feature of the devised approach is the use of the value of fractal dimensionality as a quantitative indicator of the self-similar scaled structure of functional subclusters. An algorithm for calculating fractal dimensionality has been proposed, which allows for real-time analysis of dynamic changes in the external and internal structure of the power unit process control. Threshold values of the fractal dimensionality of subclusters have been determined for comparison with current parameters under normal and emergency modes. It was established that the loss of one control level in a subcluster leads to a decrease in fractal dimensionality from 1.83 to 1.60, signaling a possible degradation of the SCADA level. A model of a digital twin of the power unit process has been built based on a system-cluster approach, which allows for the implementation of visualization, simulation, monitoring, and diagnostics functions

27 April 2026 in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
Verified
Journal Article
Closed access
VPV. V Prokhorova
V. V Prokhorova
PBP. F Budanov
P. F Budanov
KBKostiantyn Brovko
Kostiantyn Brovko
VMV. Ye Melnykov
V. Ye Melnykov
IKI. G Kyrysov
I. G Kyrysov
Purpose. Increasing the level of diagnostics of the technical condition of nuclear power plant power units by improving the methodology for continuous monitoring and forecasting the residual resource of technological equipment using digital twin models built on the basis of fractal-cluster analysis methods. Methodology. The following methods were used in the research process: fractal-cluster (for clustering data from sensors monitoring technological parameters); system-structural approach (for building a control system: power plant, power unit, technological process parameters); simulation modeling (for modeling digital twins based on graph structures and hierarchical data models). Findings. An improved method of continuous monitoring, control, diagnostics, assessment and forecasting of the state of the residual resource of technological equipment of power units of nuclear power plants using digital twin models is proposed. The value of the integrated index of quantitative assessment of the technical condition and the time of achieving the loss of functional suitability of the technological equipment of the power unit of the nuclear power plant are taken into account. Originality. Unlike traditional methods for assessing the condition of a nuclear power plant unit, the proposed method assesses the condition of the technological equipment of the power units using digital twin models. It allows taking into account the multilevel and nonlinear nature of the degradation process and the reduction of the residual resource of the equipment. A system of criteria and indicators of the integrated technical condition index based on fractal and time characteristics has been formed. This allows for prompt (in real time) response to early manifestations of defects and the increased accuracy of long-term forecasting of the resource of the technological equipment of the nuclear power plant unit. Practical value. The proposed method of continuous monitoring of the state of technological equipment of nuclear power plant power units using digital twin models ensures timely detection of defects. It increases reliability and safety, optimizes maintenance schedules and reduces the time for diagnosing emergency risks. This approach can become the basis for creating intelligent systems for continuous monitoring and life cycle management of power equipment.

30 December 2020 in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
Verified
Journal Article
Open access
PDF file
АCА. Cherniuk
А. Cherniuk
ІKІ. Kirisov
І. Kirisov
YKYe. Kachanov
Ye. Kachanov
The analysis of process of generation, transmission, distribution and consumption of electric energy is conducted in the electroenergy systems with the up‑diffused generation. The features of the characteristic modes of operations of objects of the up‑diffused generation and their influence are considered on reliability of power supply and quality of electric energy indexes for consumers. Certainly, that the process of generation of electric energy the sources of the up‑diffused generation and process of consumption of electric energy largely depend on weather and climatic terms and is characterized the substantial level of vagueness that negatively influences on drafting of balance of mine‑out and consumed electric energy. It is certain that possible not‑balance in the process of power supply of consumers substantially worsens the indexes of quality of electric energy in a network. It is indicated on actuality of this scientific and technical problem and possible methods and backer‑ups of reliability of power supply and quality of electric energy indexes are certain in networks with the up-diffused generation. Influence of weather terms is analysed on the process of generation of electric energy and climatic terms sunny and wind power-stations on the process of generation of electric energy small and the hydroelectric power and power-stations that work as on the basis of biogas technologies and organic proceeded in primary fuel. The features of generation of electric power the indicated types of power station and possible prognosis indexes that will influence on the process of management these objects of the up‑diffused generation are certain. Facilities and management backlogs are certain by a generation and consumption of electric energy in electroenergy networks with the up‑diffused generation. General conception of choice and development of management facilities offers by the process of power supply in the systems with the up‑diffused generation that takes into account the factors of considerable vagueness of entry parameters and based on the theory of construction of the reliable systems from unreliable elements.