Wing-Kin Tam

Wing-Kin Tam

Auto-generated profile, based on publicly available information

Wing-Kin Tam

Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States of America

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2011 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
WTWing-Kin Tam
Wing-Kin Tam
Raymond Kai Yu TongRaymond Kai Yu Tong
Raymond Kai Yu Tong
FMFei Meng
Fei Meng
SGShangkai Gao
Shangkai Gao
The brain-computer interface (BCI) system has been developed to assist people with motor disability. To make the system more user-friendly, it is a challenge to reduce the electrode preparation time and have a good reliability. This study aims to find a minimal set of electrodes for an individual stroke subject for motor imagery to control an assistive device using functional electrical stimulation for 20 sessions with accuracy higher than 90%. The characteristics of this minimal electrode set were evaluated with two popular algorithms: Fisher's criterion and support-vector machine recursive feature elimination (SVM-RFE). The number of calibration sessions for channel selection required for robust control of these 20 sessions was also investigated. Five chronic stroke patients were recruited for the study. Our results suggested that the number of calibration sessions for channel selection did not have a significant effect on the classification accuracy. A performance index devised in this study showed that one training day with 12 electrodes using the SVM-RFE method achieved the best balance between the number of electrodes and accuracy in the 20-session data. Generally, 8-36 channels were required to maintain accuracy higher than 90% in 20 BCI training sessions for chronic stroke patients.

3 September 2019 in BMC Biomedical Engineering
Verified
Journal Article
Open access
PDF file
WTWing-Kin Tam
Wing-Kin Tam
TWTong Wu
Tong Wu
QZQi Zhao
Qi Zhao
EKEdward Keefer
Edward Keefer
ZYZhi Yang
Zhi Yang
Many people suffer from movement disability due to amputation or neurological diseases. Fortunately, with modern neurotechnology now it is possible to intercept motor control signals at various points along the neural transduction pathway and use that to drive external devices for communication or control. Here we will review the latest developments in human motor decoding. We reviewed the various strategies to decode motor intention from human and their respective advantages and challenges. Neural control signals can be intercepted at various points in the neural signal transduction pathway, including the brain (electroencephalography, electrocorticography, intracortical recordings), the nerves (peripheral nerve recordings) and the muscles (electromyography). We systematically discussed the sites of signal acquisition, available neural features, signal processing techniques and decoding algorithms in each of these potential interception points. Examples of applications and the current state-of-the-art performance were also reviewed. Although great strides have been made in human motor decoding, we are still far away from achieving naturalistic and dexterous control like our native limbs. Concerted efforts from material scientists, electrical engineers, and healthcare professionals are needed to further advance the field and make the technology widely available in clinical use.

1 August 2010
Verified
Conference Paper
Closed access
Raymond Kai Yu TongRaymond Kai Yu Tong
Raymond Kai Yu Tong
SHS.K. Ho
S.K. Ho
PPP.M.K. Pang
P.M.K. Pang
XHX.L. Hu
X.L. Hu
WTW.K. Tam
W.K. Tam
MCM. Chen
M. Chen
A novel design of a hand functions task training robotic system was developed for the stroke rehabilitation. It detects the intention of hand opening or hand closing from the stroke person using the electromyography (EMG) signals measured from the hemiplegic side. This training system consists of an embedded controller and a robotic hand module. Each hand robot has 5 individual finger assemblies capable to drive 2 degrees of freedom (DOFs) of each finger at the same time. Powered by the linear actuator, the finger assembly achieves 55 degree range of motion (ROM) at the metacarpophalangeal (MCP) joint and 65 degree range of motion (ROM) at the proximal interphalangeal (PIP) joint. Each finger assembly can also be adjusted to fit for different finger length. With this task training system, stroke subject can open and close their impaired hand using their own intention to carry out some of the daily living tasks.

11 November 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
ANAnh Tuan Nguyen
Anh Tuan Nguyen
JXJian Xu
Jian Xu
MJMing Jiang
Ming Jiang
DLDiu Khue Luu
Diu Khue Luu
TWTong Wu
Tong Wu
ZYZhi Yang
Zhi Yang
Objective . While prosthetic hands with independently actuated digits have become commercially available, state-of-the-art human-machine interfaces (HMI) only permit control over a limited set of grasp patterns, which does not enable amputees to experience sufficient improvement in their daily activities to make an active prosthesis useful. Approach . Here we present a technology platform combining fully-integrated bioelectronics, implantable intrafascicular microelectrodes and deep learning-based artificial intelligence (AI) to facilitate this missing bridge by tapping into the intricate motor control signals of peripheral nerves. The bioelectric neural interface includes an ultra-low-noise neural recording system to sense electroneurography (ENG) signals from microelectrode arrays implanted in the residual nerves, and AI models employing the recurrent neural network (RNN) architecture to decode the subject’s motor intention. Main results . A pilot human study has been carried out on a transradial amputee. We demonstrate that the information channel established by the proposed neural interface is sufficient to provide high accuracy control of a prosthetic hand up to 15 degrees of freedom (DOF). The interface is intuitive as it directly maps complex prosthesis movements to the patient’s true intention. Significance . Our study layouts the foundation towards not only a robust and dexterous control strategy for modern neuroprostheses at a near-natural level approaching that of the able hand, but also an intuitive conduit for connecting human minds and machines through the peripheral neural pathways. Clinical trial: DExterous Hand Control Through Fascicular Targeting (DEFT). Identifier: NCT02994160.

1 August 2011
Verified
Conference Paper
Closed access
WTWing-Kin Tam
Wing-Kin Tam
ZKZheng Ke
Zheng Ke
Raymond Kai Yu TongRaymond Kai Yu Tong
Raymond Kai Yu Tong
Brain-computer interface (BCI) uses non-muscular channel of the nervous system for communication. Common Spatial Pattern (CSP) is a popular spatial filtering method used to reduce the effect of volume conduction on EEG signals. It is thought that CSP requires a large number of electrodes to be effective. Using a 20-session dataset of motor imagery BCI usage by 5 stroke patients, we demonstrated that after channel selection, CSP can still maintain a high accuracy with low number of electrodes using a newly proposed channel selection method called CSP-rank (higher than 90% with 8 electrodes). The results showed that using only the first session for channel selection, a high accuracy can be maintained in subsequent sessions. CSP-rank has been compared to the popular support vector machine recursive feature elimination (SVM-RFE). The results showed that the CSP-rank required less electrodes to maintain accuracy higher than 90% (a minimum of 8 compared to 12 of SVM-RFE) and it attained a higher maximum accuracy (91.7% compared with 90.7% of SVM-RFE). This could support clinicians to apply more BCI in routine rehabilitation.

1 August 2016
Verified
Conference Paper
Closed access
ZYZhi Yang
Zhi Yang
JXJian Xu
Jian Xu
ANAnh Tuan Nguyen
Anh Tuan Nguyen
TWTong Wu
Tong Wu
WZWenfeng Zhao
Wenfeng Zhao
WTWing-Kin Tam
Wing-Kin Tam
This paper reports a novel neurotechnology (Neuronix) and its validation through experiments. It is a miniature system-on-chip (SoC) that allows recording with simultaneous electrical microstimulation. This function has not been demonstrated before and enables precise, closed-loop neuromodulation. Neuronix represents recent advancement in brain technology and applies to both animal research and clinical applications.