Jan Stock

Jan Stock

Auto-generated profile, based on publicly available information

Jan Stock

L2R GmbH, Cliev 4, 51515 Kürten, Germany

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2024 in Resuscitation Plus
Verified
Journal Article
Open access
SWSabine Wingen
Sabine Wingen
NGNele Großfeld
Nele Großfeld
NANiels-Benjamin Adams
Niels-Benjamin Adams
ASAntonia Streit
Antonia Streit
JSJan Stock
Jan Stock
WWWolfgang A Wetsch
Wolfgang A Wetsch
App-linked real-time feedback-devices for cardiopulmonary resuscitation (CPR) aim to improve laypersons’ resuscitation quality. Resuscitation guidelines recommend these technologies in training settings. This is the first study comparing resuscitation quality of all App-linked feedback-devices currently on market. A prospective randomised simulation study was performed. After standardised instructions, participants performed 2-minutes compression-only CPR on a manikin without feedback (baseline). Afterwards, participants performed 4 × 2 min CPR with four different feedback devices in randomised order (CorPatch® Trainer, CPRBAND AIO Training, SimCPR®ProTrainer, Relay Response™) (intervention). CPR metrics (chest compression depth (CD), chest compression rate (CR), percentage of correct CD/CR (%), correct hand position, correct chest recoil, and technical preparation-time) were assessed. Devices data were compared to the baseline group using Wilcoxon testing with IBM SPSS (primary outcome). Differences between devices were analysed with ANOVA testing (secondary outcome). Normally distributed data were described as mean ± standard deviation (SD) and non-normally distributed data as Median [Interquartile range (IQR). CPR self-confidence was measured by means of questionnaire before and after feedback devices’ use. Comparison was performed by students t-test. Forty participants were involved. SimCPR®ProTrainer was the only device, which resulted in guideline-compliant chest compressions (Mean ± SD:5.37 ± 0.76) with improved chest compression depth (p < 0.001), and percentage of correct chest compression depth (p < 0.001) compared to unassisted CPR (baseline). CorPatch® Trainer as the only device with audio-visual recoil instructions resulted in improved chest recoil (Mean ± SD:72.25 ± 24.89) compared to baseline (Mean ± SD:49.00 ± 42.20; p < 0.01), while the other three devices resulted in significantly lower chest recoil rates (CPRBAND AIO Training: 37.03 ± 39.90; p < 0.01, SimCPR®ProTrainer: Mean ± SD:39.88 ± 36.50; p = 0.03, Relay Response™: Mean ± SD:36.88 ± 37.73; p = 0.02). CPR quality when using the different feedback devices differ in chest compression depth (p = 0.02), chest compression rate (p < 0.001), percentage of correct chest compression depth/rate (p = 0.03/p = 0.04), and technical preparation-time (p < 0.001). Feedback-devices’ use increased participant’s CPR self-confidence (p < 0.001). Although, CPR feedback devices show improved CPR performance in layperson in some metrics, none of the tested CPR feedback devices supported layperson in overall adequate CPR performance. More and better technical functionality is necessary, to fully utilise the potential of CPR feedback devices and to prevent a worsening of CPR performance when layperson use this technology.

24 December 2025 in Resuscitation Plus
Verified
Journal Article
Open access
ALAlexander Michael Lechleuthner
Alexander Michael Lechleuthner
KLKathrin Leupolz
Kathrin Leupolz
FRFabian Ripke
Fabian Ripke
SDSarah Dopfer
Sarah Dopfer
JSJan Stock
Jan Stock
MSMarco Strohm
Marco Strohm
Successful defibrillation requires sufficient electrical current to depolarize a critical mass of myocardial cells. The corpuls3 is available with the MAX option (MAX), which delivers its technically highest possible current for the actual impedance, instead of a fixed energy. This retrospective analysis compared shock success with MAX versus the standard 200 J setting. We retrospectively analysed ECG records from out-of-hospital cardiac arrests (OHCAs) in four German regions (May 2022–June 2024) to compare termination of fibrillation (TOF) and return of organised rhythm (ROOR) after shocks with MAX or 200 J. A total of 1457 shocks with MAX and 2348 shocks with 200 J were included. First-shock success did not differ significantly between MAX and 200 J (TOF: 81 % vs. 76 %, p = 0.11; ROOR: 66 % vs. 64 %, p = 0.66). Considering all shocks, MAX achieved higher success rates (TOF: 80 % vs. 72 %, p < 0.001; ROOR: 67 % vs. 63 %, p = 0.02). When limiting the analysis to the first three shocks, patients treated exclusively with MAX achieved first TOF after 1.17 ± 0.44 shocks, compared to 1.36 ± 0.91 shocks for those receiving only 200 J (p = 0.02). Within three shocks, TOF was reached in 93.1 % of patients receiving only MAX versus 89.3 % receiving only 200 J (p = 0.05). MAX does not improve first-shock success compared to 200 J, but overall TOF and ROOR rates are significantly higher with MAX.