Universidad Autónoma de Nuevo León (UANL), Instituto de ingeniería civil, Departamento de Estructuras, Av. Universidad, s/n CP. 66455, San Nicolás de los Garza, Nuevo León, México
Auto-generated profile, based on publicly available information
Jorge Humberto Chávez-Gómez
Universidad Autónoma de Nuevo León (UANL), Instituto de ingeniería civil, Departamento de Estructuras, Av. Universidad, s/n CP. 66455, San Nicolás de los Garza, Nuevo León, México
Reservoirs are highly relevant infrastructure assets, and now, more than ever, they play an essential role in society’s welfare and national security. Their importance is related to regional socioeconomic development due to their capacity to store water for different uses, such as human consumption, agricultural irrigation, flood control, and hydroelectric energy production, among other important services. However, many reservoirs are reaching the end of their period of life, and others are showing undesired displacements and cracking. Four 3D surveys were conducted on a reservoir that serves the Metropolitan Area of Monterrey City in Mexico. These surveys were carried out over a period of 5 years using GNSS observation to assist in understanding the actual dam kinematics, i.e., the behavior of its longitudinal and transversal displacements and the possible correlation with the reservoir level. The high‐precision leveling and close‐range remote sensing data were assessed and then mapped. The high‐precision geodetic and leveling techniques allowed us to locate and measure 84 established permanent control points with errors of about ± 0.003 m. The mapping of displacements was made possible by modeling the positive and negative translations. The highest uplifts (11 mm) occurred at the left riverbank, and the highest subsidences (−5 mm) occurred along the downstream piers from the middle of the dam crest to the right riverbank. A ground laser scanner (GLS) produced 3D digital models with geometrical and radiometric characteristics, detecting displacements among the dam crest elements. The synergy of GNSS and high‐leveling techniques allows the possibility to measure displacements, while the use of geographical information system (GIS) and geomatic techniques allows a better visualization through 2D and 3D maps validated using traditional topographical methods.
Masonry is a construction material composed of units (blocks or bricks) joined with mortar. It is one of the most widely used materials in construction resisting both vertical and horizontal forces in single and multi-family housing buildings. A correct union between the units and the mortar (interface) is essential, as is determining the resistance from the applied loads. There is a divergence in how the mortar is bedded in the construction of masonry walls. In some countries, such as Canada and Australia, regulations require that the mortar be placed in face shell bedding when hollow blocks are used. However, in countries like Mexico, regulations establish that it be placed in the net area, and construction practices often differ. Much research has been conducted to study the compressive behavior of mortar bedding in masonry of hollow concrete blocks. However, fewer studies have focused on shear behavior. This paper presents the dataset of experimental laboratory tests on wallettes built with hollow concrete blocks. Two methods of mortar bedding were employed: over the net area and the lateral face. The values obtained can be used to compare the shear strength in hollow concrete block masonry and the shear failure. Additionally, they can be useful for calibrating numerical models.
The uniaxial compressive strength is a main parameter to be considered in design of masonry structures, particularly due to gravitational loads. This dataset collection comprises test on various masonry prisms made of hollow concrete blocks. These prisms are divided into three groups: prisms consisting of 2, 3, and 4 courses, respectively. All prisms underwent testing with mortar applied over the net area (fullshell) and on the lateral face (face-shell-bedding). Ten prisms were tested for each arrangement, meaning 10 prisms with 2 courses using full-shell placement, 10 with face-shell placement, and so forth for 3 and 4 course prisms. Two linear variable differential transformers (LVDTs) were added to every prism for displacement measurements. Load measurements were conducted by using an Instron machine for the prisms with two courses, a Tinius Olsen machine for those with three courses, and a loading frame for the four-course prisms. The presented dataset includes strain-stress curves that underwent analysis and filtering. These data hold sig
Different loading conditions cause different tensile stress patterns in masonry structures. Several studies related to masonry behavior use indirect tensile tests to obtain that value, where the splitting test from ASTM-C-1006 is usually employed. In this paper, an experimental analysis of the tensile strength of hollow concrete blocks is reported. Different locations of the rod from the ASTM-C-1006 splitting test were analyzed. The tensile strength was evaluated in four different ways, placing the rod: (1) in the transversal direction over the gross area, (2) in the transversal direction over the net area, (3) in the longitudinal direction, and (4) 200 mm from the central region of the block in the longitudinal direction. The obtained results were compared with the tensile strength values measured from the direct tensile test in the longitudinal direction. In addition, an axial compressive test was performed to characterize the blocks, and a discussion about the tensile/compression ratio is shown. The experimental results from the splitting tests show that for each configuration setup, the tensile stress is different. The main result was that the splitting test over the net area with the rod positioned in the longitudinal direction can overestimate the tensile strength by more than 21% of the one over the gross area.