Zixiao Xu

Zixiao Xu

Auto-generated profile, based on publicly available information

Zixiao Xu

School of Automation, Northwestern Polytechnical University, Xian, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
ZXZixiao Xu
Zixiao Xu
DYDechang Yang
Dechang Yang
Weilin LiWeilin Li
Weilin Li
With the development of the energy Internet and the integration of multi-type energy situations, it is of great significance to study the competition game of a multi-agent microgrid group system for its development. As an emerging distributed database technology, blockchain technology has great application potential in the field of energy trading. Firstly, blockchain technology is coupled with the microgrid group transaction, and the information flow transaction model of a microgrid group based on blockchain technology is established. Aiming at this complex multi-objective optimization problem, an improved ant colony optimization algorithm is proposed to solve the model. Finally, the competitive trading model and solving algorithm are simulated and analyzed. The relevant results show that the near global optimum price strategy of each time based on the proposed model can effectively balance the efficiency of each subject in the market. In addition, the model ensures that there is no high-income and low-cost phenomenon in the trading process, therefore the security and quality of the market are guaranteed.

23 February 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
ZXZixiao Xu
Zixiao Xu
Yang QiYang Qi
Yang Qi
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Juan C. VasquezJuan C. Vasquez
Juan C. Vasquez
YWYufeng Wang
Yufeng Wang
YWYU WU
YU WU
More-electric aircraft (MEA) has evolved in the recent two decades owing to their superiority in fuel efficiency, noise reduction, and reliability compared to conventional aircraft. The power supply systems, commonly regarded as distributed interactive systems, play a paramount role in MEA, yet are facing critical concerns in terms of their stability. Impedance is a key enabling tool to study the stability of such interactive systems and therefore contributes to better design optimization. Toward this end, this paper presents a comprehensive review of the impedance modeling, stability analysis, and impedance shaping for power supply system in MEA. The three typical power supply system architectures of MEA are introduced and summarized in the first place. Then, existing studies on impedance model are reviewed. Due to the nonlinear time-varying characteristics of the AC system, it needs to be linearized. This paper discusses the characteristics and scope of applications of dq -axis linearization and harmonic linearization methods. Besides, this paper highlights the aspects of the impedance stability analysis including DC and AC stability criterion. The strengths, limitations and application scenarios of each criterion are summarized and discussed. Finally, impedance shaping methods, including structural reshaping, impedance parameter optimization, and system-level control, have also been surveyed and summarized.

26 August 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZHZhipeng He
Zhipeng He
ZXZixiao Xu
Zixiao Xu
HZHu Zhao
Hu Zhao
Weilin LiWeilin Li
Weilin Li
YZYan Zhen
Yan Zhen
WNWenjun Ning
Wenjun Ning
Series arc faults (SAFs) are important safety issues in low-voltage AC distribution networks. However, the load type and circuit topology are increasing, and arcing current features are easily affected by these factors, which makes SAF detection very challenging. This article proposes a new method for detecting SAFs in real scenarios containing multiple load types and complex circuit topologies. The proposed method uses the branch voltage coupling signal (BVCS) as the detection signal. Firstly, the wavelet transform is employed to preprocess the BVCS to simplify the representation of fault components. Secondly, the absolute value sum of wavelet transform detail coefficients (AVSDC) is utilized to characterize them. Then, the complete detection algorithm is designed based on the difference of AVSDC between normal conditions and arc faults and the continuity of SAFs. Finally, an online arc fault detection device is developed to validate the accuracy of the proposed method and its generalization ability. The results show that the proposed method has good detection accuracy under complex working conditions with multiple load types and circuit topologies.

4 February 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZXZixiao Xu
Zixiao Xu
YWYufeng Wang
Yufeng Wang
Yang QiYang Qi
Yang Qi
Weilin LiWeilin Li
Weilin Li
YWYU WU
YU WU
Juan C. VasquezJuan C. Vasquez
Juan C. Vasquez
The three-stage generator (TSG), as one of the most used more-electric aircraft generators, is crucial for the stable operation of aircraft power supply systems. The presence of numerous converters in cascade with the generator leads to complex physical and control dynamic interactions, which affect the stability of the ac bus voltage. To address the stability issue, two major contributions are made in this article. First, a dual-port modular impedance/admittance modeling method suitable for cascaded system with TSG and pulse width modulation (PWM) rectifier (TSG-PWM) is presented. In this method, a dual-port network is formed by Thevenin's theorem and Norton's theorem to analyze the modules’ stability directly. Due to the advantages of modular modeling, this method also offers generality and scalability. Subsequently, a self-defined stability margin criterion based on the Gershgorin circle theorem is proposed. This criterion can determine the ac bus voltage stability state of the actual system accurately. Compared to the generalized Nyquist stability criterion, it permits the definition of stability margins based on system requirements prior to the system design. In addition, the proposed criterion enables the determination of parameter thresholds at the stability boundary with minimal computational effort. Finally, the proposed stability criterion is validated through a hardware-in-the-loop platform using the derived dual-port network model of the cascaded system. Theoretical and experimental results agree well.

23 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZXZixiao Xu
Zixiao Xu
Yang QiYang Qi
Yang Qi
Weilin LiWeilin Li
Weilin Li
YYYongheng Yang
Yongheng Yang
The increasing deployment of power converters has led to a significant reduction in the power system inertia and consequently resulted in frequency stability issues. To improve the robustness of the grid against frequency disturbances, it is becoming more expected in many countries that renewable energy generation, such as wind turbine power systems, should provide equivalent inertia support to the power system. This can be achieved through advanced control of power converters, in addition to adding extra energy storage devices, e.g., batteries. In wind turbine systems, although the ancillary service of inertia provision can be realized by coupling the rotor speed with the grid frequency, the rotor speed recovery process affects the inertia response if the controller is not properly designed or well-tuned. To address this issue, in this paper, we propose a multi-timescale control strategy for a doubly fed induction generator (DFIG) wind turbine system. Synthetic inertia control and speed recovery control are simultaneously incorporated into the controller of the rotor-side converter, whereas their dynamics are decoupled under different timescales to avoid control conflict. Extensive simulation results are provided, which validate the efficacy of the proposed inertia emulation scheme.

29 October 2024 in IET Electric Power Applications
Verified
Journal Article
Open access
ZXZixiao Xu
Zixiao Xu
YQYang Qi
Yang Qi
WLWeilin Li
Weilin Li
YWYu Wu
Yu Wu
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Juan C. VasquezJuan C. Vasquez
Juan C. Vasquez
Due to the increasing variety of converters in more electric aircraft (MEA), the stability of the MEA power system has become a critical issue that receives wide concerns. As the primary power source for MEA, the wound rotor synchronous machine (WRSM) greatly affects the stability of the whole power system, and therefore accurate modelling of the WRSM serves as the basis for the analysis of system characteristics and even stability. Nevertheless, the complex structure and coupling of WRSM bring great challenges to small‐signal modelling methods. This paper introduces a novel method to model the WRSM in a modular and cascaded manner. Instead of deriving the complex transfer function, the proposed method uses a dual port to model each component. By connecting the dual port of each component from the rear stage to the front stage in a cascaded way, a dual‐port network can be built to describe the external impedance characteristics of the WRSM. Kirchhoff law can be applied to calculate the impedance by circumventing the complicated decoupling process. The proposed dual‐port network model has been validated on a hardware‐in‐loop platform. Furthermore, the output impedance characteristics of the AC port has also been analysed with the proposed model.