Lindsey Hanson

Lindsey Hanson

Auto-generated profile, based on publicly available information

Lindsey Hanson

Department of Chemistry, Trinity College, Hartford, Connecticut 06106, United States

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2012 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
CXChong Xie
Chong Xie
ZLZiliang Lin
Ziliang Lin
LHLindsey Hanson
Lindsey Hanson
YCYi Cui
Yi Cui
BCBianxiao Cui
Bianxiao Cui
Action potentials have a central role in the nervous system and in many cellular processes, notably those involving ion channels. The accurate measurement of action potentials requires efficient coupling between the cell membrane and the measuring electrodes. Intracellular recording methods such as patch clamping involve measuring the voltage or current across the cell membrane by accessing the cell interior with an electrode, allowing both the amplitude and shape of the action potentials to be recorded faithfully with high signal-to-noise ratios1. However, the invasive nature of intracellular methods usually limits the recording time to a few hours1, and their complexity makes it difficult to simultaneously record more than a few cells. Extracellular recording methods, such as multielectrode arrays2 and multitransistor arrays3, are non-invasive and allow long-term and multiplexed measurements. However, extracellular recording sacrifices the one-to-one correspondence between the cells and electrodes, and also suffers from significantly reduced signal strength and quality. Extracellular techniques are not, therefore, able to record action potentials with the accuracy needed to explore the properties of ion channels. As a result, the pharmacological screening of ion-channel drugs is usually performed by low-throughput intracellular recording methods4. The use of nanowire transistors5,6,7, nanotube-coupled transistors8 and micro gold-spine and related electrodes9,10,11,12 can significantly improve the signal strength of recorded action potentials. Here, we show that vertical nanopillar electrodes can record both the extracellular and intracellular action potentials of cultured cardiomyocytes over a long period of time with excellent signal strength and quality. Moreover, it is possible to repeatedly switch between extracellular and intracellular recording by nanoscale electroporation and resealing processes. Furthermore, vertical nanopillar electrodes can detect subtle changes in action potentials induced by drugs that target ion channels.

5 June 2017 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
WZWenting Zhao
Wenting Zhao
LHLindsey Hanson
Lindsey Hanson
HLHsin-Ya Lou
Hsin-Ya Lou
MAMatthew Akamatsu
Matthew Akamatsu
PCPraveen D. Chowdary
Praveen D. Chowdary
BCBianxiao Cui
Bianxiao Cui
Nanoscale plasma membrane curvature, generated in a controllable fashion by vertically aligned nanostructure arrays, promotes the accumulation of key endocytic proteins in live cells. Clathrin-mediated endocytosis (CME) involves nanoscale bending and inward budding of the plasma membrane, by which cells regulate both the distribution of membrane proteins and the entry of extracellular species1,2. Extensive studies have shown that CME proteins actively modulate the plasma membrane curvature1,3,4. However, the reciprocal regulation of how the plasma membrane curvature affects the activities of endocytic proteins is much less explored, despite studies suggesting that membrane curvature itself can trigger biochemical reactions5,6,7,8. This gap in our understanding is largely due to technical challenges in precisely controlling the membrane curvature in live cells. In this work, we use patterned nanostructures to generate well-defined membrane curvatures ranging from +50 nm to −500 nm radius of curvature. We find that the positively curved membranes are CME hotspots, and that key CME proteins, clathrin and dynamin, show a strong preference towards positive membrane curvatures with a radius <200 nm. Of ten CME-related proteins we examined, all show preferences for positively curved membrane. In contrast, other membrane-associated proteins and non-CME endocytic protein caveolin1 show no such curvature preference. Therefore, nanostructured substrates constitute a novel tool for investigating curvature-dependent processes in live cells.

8 October 2012 in Nano Letters
Verified
Journal Article
Closed access
LHLindsey Hanson
Lindsey Hanson
ZLZiliang Carter Lin
Ziliang Carter Lin
CXChong Xie
Chong Xie
YCYi Cui
Yi Cui
BCBianxiao Cui
Bianxiao Cui

18 May 2015 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
LHLindsey Hanson
Lindsey Hanson
WZWenting Zhao
Wenting Zhao
HLHsin-Ya Lou
Hsin-Ya Lou
ZLZiliang Carter Lin
Ziliang Carter Lin
SLSeok Woo Lee
Seok Woo Lee
BCBianxiao Cui
Bianxiao Cui

3 September 2010 in Nano Letters
Verified
Journal Article
Closed access
CXChong Xie
Chong Xie
LHLindsey Hanson
Lindsey Hanson
WXWenjun Xie
Wenjun Xie
ZLZiliang Lin
Ziliang Lin
BCBianxiao Cui
Bianxiao Cui
YCYi Cui
Yi Cui

22 February 2011 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
CXChong Xie
Chong Xie
LHLindsey Hanson
Lindsey Hanson
YCYi Cui
Yi Cui
BCBianxiao Cui
Bianxiao Cui
Observing individual molecules in a complex environment by fluorescence microscopy is becoming increasingly important in biological and medical research, for which critical reduction of observation volume is required. Here, we demonstrate the use of vertically aligned silicon dioxide nanopillars to achieve below-the-diffraction-limit observation volume in vitro and inside live cells. With a diameter much smaller than the wavelength of visible light, a transparent silicon dioxide nanopillar embedded in a nontransparent substrate restricts the propagation of light and affords evanescence wave excitation along its vertical surface. This effect creates highly confined illumination volume that selectively excites fluorescence molecules in the vicinity of the nanopillar. We show that this nanopillar illumination can be used for in vitro single-molecule detection at high fluorophore concentrations. In addition, we demonstrate that vertical nanopillars interface tightly with live cells and function as highly localized light sources inside the cell. Furthermore, specific chemical modification of the nanopillar surface makes it possible to locally recruit proteins of interest and simultaneously observe their behavior within the complex, crowded environment of the cell.