Electrical Engineering Faculty, Eindhoven University of Technology, Eindhoven, the Netherlands

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2011
Verified
Conference Paper
Closed access
YXYu Xiang
Yu Xiang
VCVladimir Cuk
Vladimir Cuk
JCJ. F. G. Cobben
J. F. G. Cobben
Residual current devices (RCDs) are most commonly used as a part of the protection system in low voltage installations. RCDs are supposed to disconnect the supply whenever the imbalance current between the live conductor(s) and the neutral conductor, i.e. residual current, exceeds the predetermined value. Such an imbalance is sometimes caused by current leakage through the body of a person who is grounded and accidentally touching the energized part of the circuit, which could result in a lethal shock. However, harmonic components in ground fault current may influence the tripping sensitivity of RCDs, and the protection against electrical shock may not be effective. In the paper, results of theoretical analysis and experiments are presented. Several mechanisms which could influence the tripping sensitivity of RCDs are validated, and their dominant conditions are identified.

6 October 2015 in IEEE Power and Energy Technology Systems Journal
Verified
Journal Article
Open access
YXYu Xiang
Yu Xiang
JCJoseph F. G. Cobben
Joseph F. G. Cobben
This paper proposes a statistical approach for section-based fault location in medium voltage (MV) grids with underground cables, using Bayesian inference. The proposed approach considers several important uncertainties in the MV grid, including measurement errors, fault breakdown resistance, and the inaccuracies of zero-sequence parameters. The approach first obtains the prior distribution of the fault position from the component failure database, the readings of the transmitted fault indicators, and the relevant digging activity record. With the estimated prefault grid status and the measured transient voltages/currents, the posterior distribution is then calculated based on Bayes' theorem. To solve the problem numerically, the Monte Carlo integration is applied and a two-step calculation procedure is proposed. Simulations are performed on a typical European MV feeder to demonstrate the feasibility of the approach. The distribution grid operators can use the calculated posterior distribution to rank the possible faulted sections and to facilitate the restoration process, which can reduce the interruption duration of power supply.

1 September 2013 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
XWXiao Bo Wang
Xiao Bo Wang
TLTie Bing Lu
Tie Bing Lu
YZYong Zan Zhen
Yong Zan Zhen
YXYu Xiang
Yu Xiang
With the HVDC transmission projects developing rapidly, the relevent electromagnetic environment problems are widely concerned, of which the transient electric caused by the conductor electrification in ionized field may seriously influences the feelings of people. To invesigate the tansient electric shock procedure, the transient current is measured in the experiment. The simulation results agrees well with the measured values and the validity of the simulation model is verified. The simulation results show that the resistance in the discharging circuit can reduce the current evidently. It is also found that the metal objects under the HVDC lines should be grouded to avoid discharging when touched by the people.

1 November 2015
Verified
Conference Paper
Closed access
GYGu Ye
Gu Ye
YXY. Xiang
Y. Xiang
VCVladimir Cuk
Vladimir Cuk
JCJ. F. G. Cobben
J. F. G. Cobben
The performance of the system regarding voltage dips is commonly characterized with the SARFIx index, which gives the average frequency of voltage dips. Due to the limited number of measurement points, the actual residual voltages of many nodes are not taken into account when the index is calculated. As it's impossible to measure the dip level at every node of a feeder, the voltage dips occurring at nonmonitored nodes should be estimated from the values recorded at monitored nodes with the consideration of measurement accuracy. This paper proposes a voltage dip state estimation method based on Bayesian inference. The performance of the proposed method is assessed through case study applied in a typical distribution network. Monte Carlo simulation is used to obtain the statistic results. The proposed method shows the flexibility of different measurement quantities and the adequacy for the analysis of distribution networks.

21 May 2026 in Sustainable Energy, Grids and Networks
Verified
Journal Article
Open access
DLDong Liu
Dong Liu
STSander Timmerman
Sander Timmerman
YXYu Xiang
Yu Xiang
EHEnsieh Hosseini
Ensieh Hosseini
Peter PalenskyPeter Palensky
Peter Palensky
Pedro P. VergaraPedro P. Vergara
Pedro P. Vergara