Pengxiao Xu

Pengxiao Xu

Auto-generated profile, based on publicly available information

Pengxiao Xu

55th Research Institute of China Electronics Technology Group Corporation, Nanjing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

9 December 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JRJinlu Ruan
Jinlu Ruan
LCLiang Chen
Liang Chen
PXPengxiao Xu
Pengxiao Xu
YZYapeng Zhang
Yapeng Zhang
XDXue Du
Xue Du
LZLeidang Zhou
Leidang Zhou
Scintillation detector is one of the key detectors for measurements of pulsed radiation fields due to its high sensitivity, and fast time response. In a scintillation detector, the photomultiplier tube need have a high gain, a fast temporal response, and a large maximum linear current (MLC). The hybrid photomultiplier tube based on a SiC detector (SiC-HPMT) with a larger MLC is expected to become one kind of the important photon detectors for the measurements of pulsed radiation fields with a high intensity. However, the inherent problem is that the currently used hybrid photomultiplier is severely restricted by a low gain. On the basis of maintaining the original excellent properties, such as fast temporal response and large MLC, a novel hybrid photomultiplier tube (MCP-SiC-HPMT) which is composed of SiC-HPMT and a microchannel plate (MCP) is developed to offer an effective way to improve the gain. According to the experimental results, the influence laws of the accelerating and focusing voltage and the bias voltage of the SiC detector on its properties such as the gain, dark current, temporal response, and MLC were obtained. The gain and the MLC of the MCP-SiC-HPMT can reach over 10 5 and 500 mA, respectively. Moreover, the result demonstrated that the temporal response of the MCP-SiC-HPMT has a leading edge of about 2 ns and a FWHM of about 4 ns, which is almost same as that of the SiC-HPMT. The addition of the MCP does not only improve their gain, but also have no significant impact on its excellent performance. The detector based on an EJ228 scintillator and the MCP-SiC-HPMT successfully measured the multiple peaks characteristic of a pulsed X-ray source, which indicated that the MCP-SiC-HPMT can well meet the requirements of the temporal characteristics measurement of a pulsed device. The detector combining a stilbene scintillator with the developed MCP-SiC-HPMT can well discriminate the neutron and gamma rays produced by a D-T neutron source. The successful development of the MCP-SiC-HPMT can further expand the applications in pulsed radiation field measurements and show the great potential in the field of particle detections for hybrid photomultiplier tubes (HPMTs).