Nicholas M. Kuenning

Nicholas M. Kuenning

Auto-generated profile, based on publicly available information

Nicholas M. Kuenning

Department of Mechanical and Aerospace Engineering, University of California (UCLA), Los Angeles, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
ANAnil P Nair
Anil P Nair
NMNicolas Q Minesi
Nicolas Q Minesi
CJChristopher Jelloian
Christopher Jelloian
NKNicholas M Kuenning
Nicholas M Kuenning
RSR Mitchell Spearrin
R Mitchell Spearrin
Variations in injection-current waveform are examined using diplexed radio-frequency modulation with continuous-wave distributed-feedback (CW-DFB) lasers, with the aim to maximize the spectral tuning range and signal-to-noise ratio for MHz-rate laser absorption spectroscopy (LAS). Utilizing a bias-tee circuit, laser chirp rates are shown to increase by modulating the AC input voltage using square waves instead of sine waves and by scanning the laser below the lasing threshold during the modulation period. The effect of waveform duty cycle and leading-edge ramp rate are further examined. A spectral scan depth on the order of 1 cm −1 at a scan frequency of 1 MHz is achieved with a representative CW-DFB quantum cascade laser near 5 μm. Distortion of high-frequency optical signals due to detector bandwidth is also examined, and limitations are noted for applications with narrow spectral features and low-bandwidth detectors. Based on common detection system limitations, an optimization approach is established for a given detection bandwidth and target spectra. A representative optimization is presented for measurements of sub-atmospheric carbon monoxide spectra with a 200-MHz detection system. The methods are then demonstrated to resolve transient gas properties (pressure and temperature) via LAS at MHz rates in a detonation tube and shock tube facility. An appendix detailing a first-order model of high-speed distributed feedback laser tuning dynamics is also included to support the experimental observations of this work.

31 July 2024 in Combustion and Flame
Verified
Journal Article
Closed access
NKNicholas M. Kuenning
Nicholas M. Kuenning
ANAnil P. Nair
Anil P. Nair
AKAlex R. Keller
Alex R. Keller
NMNicolas Q. Minesi
Nicolas Q. Minesi
EOEmre Ozen
Emre Ozen
RSR. Mitchell Spearrin
R. Mitchell Spearrin

17 March 2023 in Applied Physics B
Verified
Journal Article
Open access
PDF file
ANAnil P. Nair
Anil P. Nair
NMNicolas Q. Minesi
Nicolas Q. Minesi
NKNicholas M. Kuenning
Nicholas M. Kuenning
AKAlex R. Keller
Alex R. Keller
RSR. Mitchell Spearrin
R. Mitchell Spearrin
An optical method for high-speed line-of-sight pressure measurements using infrared laser absorption spectroscopy is presented with detailed uncertainty analysis related to thermodynamic and compositional variation in combustion environments. The technique exploits simultaneous sub-microsecond sensing of temperature and mole fraction to extract pressure from collisional line broadening at MHz rates. A distributed-feedback quantum-cascade laser near 5 $$\upmu $$ μ m in a bias-tee circuit is used to spectrally resolve multiple rovibrational transitions in the P-branch of the fundamental band of carbon monoxide, which may be seeded or nascent to reacting flows. A comprehensive approach for estimating collisional line broadening in complex combustion gas mixtures is presented. Uncertainty is quantified for a wide range of conditions, reflecting different fuels, equivalence ratios, reaction progress, and combustion modes (deflagration and detonation), which influence gas composition and temperature. The sensor was evaluated for accuracy and precision in both a high-enthalpy shock-tube facility in hydrocarbon–air ignition experiments and behind ethylene–oxygen detonation waves in a detonation-impulse tube facility at temperatures from 1500 to 3000 K and pressures from 0.5 to 10 bar. Pressure measurements were compared to measurements by piezoelectric pressure transducers and to theoretical estimates from normal-shock and Chapman-Jouguet simulations. The high-speed path-integrated optical pressure measurement offers an alternative to traditional electromechanical transducers that are constrained to values at wall boundaries and have proven unreliable in some harsh reacting flows.

12 December 2022 in Fuel
Verified
Journal Article
Closed access
ISIsabelle C. Sanders
Isabelle C. Sanders
NKNicholas M. Kuenning
Nicholas M. Kuenning
NMNicolas Q. Minesi
Nicolas Q. Minesi
DPDaniel I. Pineda
Daniel I. Pineda
RSR. Mitchell Spearrin
R. Mitchell Spearrin

23 July 2024 in Proceedings of the Combustion Institute
Verified
Journal Article
Closed access
NKNicholas M. Kuenning
Nicholas M. Kuenning
NMNicolas Q. Minesi
Nicolas Q. Minesi
BHBrett A. Honaker
Brett A. Honaker
RSR. Mitchell Spearrin
R. Mitchell Spearrin

3 June 2023 in Journal of Quantitative Spectroscopy and Radiative Transfer
Verified
Journal Article
Closed access
NKNicholas M. Kuenning
Nicholas M. Kuenning
ISIsabelle C. Sanders
Isabelle C. Sanders
NMNicolas Q. Minesi
Nicolas Q. Minesi
DPDaniel I. Pineda
Daniel I. Pineda
RSR. Mitchell Spearrin
R. Mitchell Spearrin