Donald Grahame Holmes

Donald Grahame Holmes

Auto-generated profile, based on publicly available information

Donald Grahame Holmes

RMIT University, Melbourne, VIC, Australia

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Cungang HuCungang Hu
Cungang Hu
ZYZheng Yin
Zheng Yin
TRTao Rui
Tao Rui
ZZZhenbin Zhang
Zhenbin Zhang
Weixiang ShenWeixiang Shen
Weixiang Shen
DHDonald Grahame Holmes
Donald Grahame Holmes
An improved model-free predictive current control scheme based on double voltage vector for two-level voltage source inverters (2L-VSIs) is proposed in this article. First, two basic voltage vectors (VVs) are chosen in each control period, whose durations are calculated based on the cost function. Then, a novel current gradient updating method is developed by using the applied two VVs to calculate the current gradients of the remaining six VVs. As a result, the stagnation effect can be eliminated and current ripples and total harmonic distortion can be reduced effectively. In addition, due to the nature of vector diagram symmetry, the processing of current gradient updating is simplified and the calculation speed is increased. The effectiveness of the proposed scheme is verified by simulation and experimental results from the 2L-VSI system.

5 June 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYunlei Zhang
Yunlei Zhang
WQWang Qunjing
Wang Qunjing
Cungang HuCungang Hu
Cungang Hu
Weixiang ShenWeixiang Shen
Weixiang Shen
DHDonald Grahame Holmes
Donald Grahame Holmes
XYXinghuo Yu
Xinghuo Yu
A novel nine-level inverter topology for low voltage applications is proposed in this paper. Each phase of the inverter is composed of a T type three level cell and an active neutral point clamp three level cell. The operation principles and current conduction paths are analyzed in detail and phase-disposition sinusoidal pulse width modulation is used to balance voltages of flying capacitors and neutral point. The mathematical relationship between the capacitance and the desired ripple in the inverter output is established to select the intermediate capacitance value. Compared with other nine-level inverters suitable for low voltage applications, the proposed inverter has advantages in a number of gate drivers, a number of dc sources and efficiency. Simulation and experimental results under different settings of modulation index, power factor, output frequency and load are presented to verify the effectiveness and performances of the proposed inverter.

15 March 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JRJan Riedel
Jan Riedel
DHDonald G. Holmes
Donald G. Holmes
BMBrendan P. McGrath
Brendan P. McGrath
CTCarlos Teixeira
Carlos Teixeira
A major advantage of the dual active bridge (DAB) dc-dc converter is its ability to operate under zero voltage switching (ZVS) conditions to reduce switching losses. However, when the ac link coupling transformer is conventionally designed to minimize its magnetizing current, nonideal switching conditions almost invariably lead to hard switching operation at particular power transfer levels and dc-dc voltage ratios. This paper presents a mathematically based design approach for a coupling transformer with a reduced magnetizing inductance that creates just sufficient ac link circulating current to maintain continuous ZVS operation over the converter's entire specified operating range without incurring significant additional losses. The required magnetizing inductance reduction is found to be a function of the inherent transformer leakage inductances, switching dead-time, and device parasitic capacitances. The analysis approach is validated by matching experimental results.

22 May 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TRTao Rui
Tao Rui
ZFZhuangzhuang Feng
Zhuangzhuang Feng
Cungang HuCungang Hu
Cungang Hu
ZYZheng Yin
Zheng Yin
Wenping CaoWenping Cao
Wenping Cao
DHDonald Grahame Holmes
Donald Grahame Holmes
Model-free predictive current control (MFPCC) methods based on look-up tables (LUTs) have been widely applied in voltage source inverters (VSIs) due to their simple implementation and excellent robustness. However, the performance of the VSIs is affected by the voltage vector used, accuracy of current gradients, and sampling noise. In order to improve these, a new double-vector MFPCC method is proposed in this article. First, a synthetic voltage vector composed of double vectors is applied in each control period to reduce current ripples, where the durations of the double vectors are calculated using predicted current gradients. Next, an extended LUT is designed by using the current gradients of the applied synthetic voltage vectors to update all current gradients of eight basic voltage vectors, so as to increase the accuracy of current gradients. Then, the effect of the sampling noise on MFPCC is analyzed in detail and suppressed by a sliding mode observer for the VSIs. Finally, simulation and experimental results have verified the effectiveness of the proposed method.

4 June 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ANAhmad Afif Nazib
Ahmad Afif Nazib
DHDonald Grahame Holmes
Donald Grahame Holmes
BMBrendan P. McGrath
Brendan P. McGrath
Current regulation of inductive–capacitive–inductive (LCL) grid-connected inverters usually requires multiple current sensors to actively damp the filter resonance. Inverter-side current regulation avoids this issue because of its inherent LCL filter damping properties but does not accurately control the grid-side current, particularly with distorted grids. Furthermore, both strategies typically require high-quality voltage sensors to maintain precise grid synchronization. This article proposes a novel current control strategy for LCL grid-connected inverters that only requires inverter-side current sensors. The strategy uses the resonator output states of a stationary reference frame (SRF) proportional resonant (PR) current regulator to estimate the grid voltage phase and filter capacitor current and, thus, achieve self-synchronized indirect regulation of the grid-side current. The effectiveness of the approach has been verified using simulation and matching experimental investigations.

19 July 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
LJLinton David James
Linton David James
CTCarlos Alberto Teixeira
Carlos Alberto Teixeira
RWRichardt Howard Wilkinson
Richardt Howard Wilkinson
BMBrendan P. McGrath
Brendan P. McGrath
DHDonald Grahame Holmes
Donald Grahame Holmes
JRJan Riedel
Jan Riedel
Resonant mode dual active bridge (DAB) bi-directional DC–DC converters using either an inductive-capacitive-inductive (LCL) or a capacitive-inductive-capacitive (CLC) AC-port network offer several performance benefits compared to more conventional non-resonant filter DAB topologies. This includes a reduction in the circulating power between the two bridges, which consequently enables the conduction loss to be minimized and the physical converter volume to be reduced. However, these gains also require that soft-switching is maintained, which is very challenging to achieve across all operating conditions, particularly at light loads. This paper investigates the zero-voltage-switching (ZVS) capability of resonant mode DAB converters, applying Fourier analysis to the converter modulation patterns to quantify the ZVS boundaries analytically. The resulting analytic formulations also quantify the DAB real and reactive power flows, which subsequently enables the identification of modulation conditions that improve the converter's soft-switching and reactive circulating power flow behaviour. The analysis is verified using detailed time-domain PSIM simulations matched to experimental DAB converters equipped with both LCL and CLC filters.