The third-harmonic injection two-stage matrix converter (3TSMC) not only inherits the advantages of the conventional two-stage matrix converter (TSMC), but also has simple modulation strategy and low switching losses. The injection current control is the key to achieving sinusoidal input currents of 3TSMC. The injection current reference consists of the third harmonic and its odd harmonics, making it difficult to obtain high control accuracy with a proportional integral (PI) controller. In this paper, a control scheme is proposed for the injection current of 3TSMC, which consists of an improved odd-harmonic repetitive controller (IORC), a PI controller and a feedforward controller. Compared with the conventional repetitive controller (CRC) and existing odd-harmonic repetitive controllers (ORC), the IORC has the highest gains and bandwidths at odd-harmonic frequencies, offering the proposed control scheme high control accuracy and fast transient response. The stability conditions of the system with the proposed control scheme are analyzed, and the design guidelines for the control parameters are provided on this basis. The experimental results demonstrate the effectiveness of the proposed control scheme.
8 February 2022 in IEEE Transactions on Power Electronics
In this article, an improved topology of the third-harmonic injection two-stage matrix converter (3TSMC) is proposed, which not only ensures that the input reactive power control capability is independent of the voltage transfer ratio (VTR) and the load conditions but also achieves high-quality mains current waveforms. To solve the problem of injection current control error in nonunit input power factor operation of 3TSMC, the third-harmonic injection current is decomposed into the active and reactive components, which are, respectively, controlled by the original injection current control bridge arm and an additional bridge arm named reactive power control bridge arm (RB). The maximum current of the inductor of RB is equal to the absolute value of the required input reactive current amplitude and will not increase with the increase of the VTR. The design criteria of the inductor of RB are discussed. To ensure the closed-loop stability under two injection directions, the controller of the injection current reactive component is designed. The effectiveness of the proposed topology and control strategy is verified by the experimental results.
23 November 2020 in IEEE Transactions on Power Electronics
The third-harmonic injection two-stage matrix converter (3TSMC) not only possesses the advantages of a TSMC, but also enhances the input reactive power control capability. Due to the input current deviation caused by the voltage ripple across the input filter capacitors, the mains currents of the 3TSMC are distorted at sector boundaries. To improve mains current quality, this article proposes a mains current distortion suppression method for a 3TSMC, which adds a prefilter to the output side of the input voltage selector to reduce the input current harmonics. As a result, the input filter capacitor voltage ripple and the input current deviation are reduced. The details of design of the prefilter are explained mathematically. To compensate for the dc-link voltage variation after topology improvement, an algorithm based on calculation of the voltage drops across the prefilter inductors is proposed, which can further improve the mains current performance. The feasibility of the proposed method is verified by simulation and experimental results.
15 February 2024 in IEEE Transactions on Power Electronics
Third-harmonic current injection (3rd-HCI) active filter circuit could be utilized to eliminate low frequency harmonics generated by the three-phase uncontrolled rectifier. However, some problems exist when the circuit operates in the 115Vrms/400Hz aircraft power system. The inductor in the 3rd-HCI active filter circuit is not strictly volt-second balance in one switching period, resulting in injection current error and AC line current distortions. The problem is more severe in the 400Hz power system since the imbalance degree increases with a higher AC frequency. Moreover, the common method to mitigate the AC line current distortions is using a smaller inductor, which will increase the inductor current ripple and high frequency harmonic components. This paper investigates the distortion mechanisms and reveals the relationship between current distortion and volt-second imbalance, and the maximum allowed inductance is determined under every operating point. Then, an improved circuit based on ripple current cancellation technique is proposed to realize quasi-zero ripple in the inductor current and to reduce the high frequency harmonics in the AC line currents, which extends the operating range of the circuit significantly. Finally, the correctness of analysis and validity of proposed circuit are verified by experimental results based on a 115Vrms/400Hz/5kW prototype.
12 December 2024 in IEEE Transactions on Industrial Electronics
Three-phase uncontrolled rectifiers have been widely adopted due to the characteristics of robustness and high efficiency, but have the disadvantage of harmonic pollution. Third-harmonic current injection (3rd-HCI) active filter circuit could remove the harmonics. However, new problems occur and lead to current distortions again when the ac line frequency increases, especially in the more electric aircraft applications where the ac line frequency is 360–800 Hz. In this article, the mechanism of current distortions at higher ac line frequency is discussed first. The inductor in the 3rd-HCI active filter circuit is volt-second imbalance. As the ac line frequency increases, the imbalance degree is more severe and then causes current distortions. Therefore, the inductance must be reduced, resulting in larger current ripple and more high-frequency components in the ac line current. Further, based on flying capacitor three-level topology, this article proposed an improved 3rd-HCI active filter circuit and the corresponding control strategy, which not only reduces the current ripple significantly but also mitigates the ac line current distortions. Besides, the input filter capacitive current compensation is also considered to improve the power factor at light load. Finally, all the analysis are verified by experimental results on a 115 Vrms/360–800 Hz/5 kW prototype.
In this paper, an active damping control strategy based on modifying third-harmonic injection reference current and output reference current is proposed for hybrid active third-harmonic injection matrix converter (H3IMC) to improve system instability. First, the system stability when H3IMC adopts no damping methods and passive damping method is analyzed through small-signal modeling and root locus analysis. Then, the active damping method based on virtual damping branch is applied to H3IMC. A specific implementation method based on the modification of reference third harmonic injection current is proposed, which can realize active damping control strategy directly and effectively by injecting the damping signal into the reference third harmonic injection current, and avoid the problem of reducing the control freedom of the output side. Finally, simulation results illustrate that, under the condition of the same parameters, the proposed active damping control strategy performs the same as passive damping control in damping at source side and better in filtering.