Sushil K. Dwivedi

Sushil K. Dwivedi

Auto-generated profile, based on publicly available information

Sushil K. Dwivedi

Michigan Technological University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2018 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
RARashid Ali
Rashid Ali
RGRamesh C. Gupta
Ramesh C. Gupta
SDSushil K. Dwivedi
Sushil K. Dwivedi
AMArvind Misra
Arvind Misra
A new chromogenic and fluorogenic hydrazone derivative of aminobenzthiazole and 2-hydroxy-1-naphthaldehyde was developed as a sensitive molecular probe, NTS, for the detection of fluoride (F−) and cyanide (CN−) anions. The photophysical and sensing behaviors of the probe, NTS, were investigated by absorption and fluorescence studies. Interestingly, in partial aqueous medium (DMSO/H2O 9 : 1, v/v), the probe shows a selective fluorescence “turn-on” response to both the anions. An excited state proton transfer mechanism (ESPT) has been followed theoretically and by means of spectroscopic studies. The immediate visualized color change of NTS with the respective anions on test paper strips and silica coated slides suggested the applicability of the probe to sense dual anions on solid surfaces and in solution as a chemosensor for fluoride and as a chemodosimeter for cyanide anions, respectively.

25 February 2019 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
SDSushil K. Dwivedi
Sushil K. Dwivedi
SRSyed S. Razi
Syed S. Razi
AMArvind Misra
Arvind Misra
In the present study, we described the design and synthesis of an azo auxochrome containing a 2-aminothiazolyl coumarin and naphthalene conjugate as a molecular probe 5. Upon interaction with anions, the probe 5 displayed a naked-eye sensitive colorimetric response towards the detection of cyanide (CN−) and acetate (AcO−) anions in a 50% aqueous–ethanol (EtOH : H2O; v/v, 1 : 1) solution. The limits of detection for the cyanide and acetate anions were found to be 0.756 and 0.916 μM, respectively. The mechanism of interaction between the probe and both the anions has been confirmed by different spectroscopic data. The 1H NMR, 13C NMR, FTIR and HRMS data clearly confirmed the deprotonation of probe 5 in the presence of both anions. Moreover, the molecular probe 5 has shown good compatibility for the detection of CN− and AcO− anions on test paper strips.

7 April 2025 in ACS Applied Bio Materials
Verified
Journal Article
Closed access
DADilka Liyana Arachchige
Dilka Liyana Arachchige
SDSushil K. Dwivedi
Sushil K. Dwivedi
PAPeter Agyemang
Peter Agyemang
HLHenry Lanquaye
Henry Lanquaye
JPJoseph Peters
Joseph Peters
HLHaiying Liu
Haiying Liu

5 February 2025 in ACS Applied Bio Materials
Verified
Journal Article
Closed access
HLHenry Lanquaye
Henry Lanquaye
SDSushil K. Dwivedi
Sushil K. Dwivedi
XLXinzhu Li
Xinzhu Li
PAPeter Agyemang
Peter Agyemang
GRGrace Rickauer
Grace Rickauer
HLHaiying Liu
Haiying Liu

6 January 2025 in ACS Applied Bio Materials
Verified
Journal Article
Closed access
AOAdenike Mary Olowolagba
Adenike Mary Olowolagba
OAOmowunmi Rebecca Aworinde
Omowunmi Rebecca Aworinde
SDSushil K. Dwivedi
Sushil K. Dwivedi
MIMicah Olamide Idowu
Micah Olamide Idowu
DADilka Liyana Arachchige
Dilka Liyana Arachchige
HLHaiying Liu
Haiying Liu

3 July 2025 in ACS Applied Bio Materials
Verified
Journal Article
Closed access
IKIshana Kathuria
Ishana Kathuria
SPSubash Pandey
Subash Pandey
RSRonald J. Schwandt
Ronald J. Schwandt
PAPeter Agyemang
Peter Agyemang
DADilka Liyana Arachchige
Dilka Liyana Arachchige
RLRudy Luck
Rudy Luck