1 June 2016 in Energy Conversion and Management
1 November 2019 in Applied Thermal Engineering
1 October 2015 in Bioresource Technology
1 December 2016 in Energy Procedia
27 November 2017 in Journal of Testing and Evaluation
This article presented the detailed energy and exergy analysis performed on 4 different configurations of solar photovoltaic thermal collectors under Chennai climatic conditions. A comparative performance study of all the four different configurations was performed considering two mass flow rates of air as 0.00847 and 0.01130 kg/s. The parameters such as PV temperature, inlet and outlet air flow temperatures in the cooling channels, solar radiation, and ambient temperature were analyzed and studied in detail. It was found that the collector performance enhanced with increase in air velocity with further increase in heat transfer coefficient between the absorber surface and air. The experimental results obtained from the present work and the experimental performances of previously published results are found to be in good agreement. The electrical efficiency was from 9.8 to 12.9 % for 0.00847 kg/s and from 10.3 to 13.9 % for mass flow rate of air 0.0113 kg/s. The maximum thermal efficiency lies between 4.3 and 12.4 % for the mass flow rate of air 0.00847 kg/s and from 6.5 to 15.9 % for mass flow rate of air 0.01130 kg/s, respectively. Similarly, the maximum exergy efficiency ranges from 11.2 to 38.6 % for mass flow rate of air 0.00847 kg/s, and it varies between 18.4 and 49.4 % for mass flow rate of air 0.01130 kg/s.
1 January 2015 in Thermal Science
The article represents an experimental investigation of friction and heat transfer characteristics of divergent / convergent rectangular ducts with an inclination angle of 1? in the y-axis. Measurements were taken for a convergent / divergent rectangular duct of aspect ratio AR at inlet1.25 and outlet in convergent channel 1.35; but in case of divergent duct it can be reversed. The four uniform rib heights, e = 3, 6, 9 and 12 mm the ratio between rib height to hydraulic mean diameter (e/Dm) are 34.8, 69.7, 104.6 and 138.7 a constant rib pitch distance, P = 60 mm has been used. The flow rate in terms of average Reynolds number based on the hydraulic mean diameter (Dm) is 86 mm of the channel was in a range of 20,000 to 50,000. The two ceramic heating strip of 10 mm thickness is used as a heating element have attached on top and bottom surfaces for the test sections. The heat transfer performance of the divergent / convergent ducts for 3, 6, 9 and 12 mm ribs was conducted under identical mass flow rate based on the Reynolds number. In our experiments has totally 8 different ducts were used. In addition, the acceleration / deceleration caused by the cross section area, the divergent duct generally shows enhanced heat transfer behavior for four different rib sizes, while the convergent duct has an appreciable reduction in heat transfer performance. From result point view divergent duct with 3 mm height ribbed square duct gets maximum heat transfer coefficient with minimum friction loss over the other convergent / divergent ducts.