Won Hyuk Jang

Won Hyuk Jang

Auto-generated profile, based on publicly available information

Won Hyuk Jang

Division of Integrative Biosciences and Biotechnology, Pohang University of Science and Technology, San 31, Hyoja-dong, Nam-gu, Pohang, Gyeongbuk 790-784, South Korea

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2018 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
KPKyeng Min Park
Kyeng Min Park
KBKangkyun Baek
Kangkyun Baek
YKYoung Ho Ko
Young Ho Ko
SAShrinidhi Annadka
Shrinidhi Annadka
JMJames Murray
James Murray
KKKimoon Kim
Kimoon Kim

12 January 2016 in Scientific Reports
Verified
Journal Article
Open access
WJWon Hyuk Jang
Won Hyuk Jang
SSSehwan Shim
Sehwan Shim
TWTaejun Wang
Taejun Wang
YYYeoreum Yoon
Yeoreum Yoon
JMJae Kyung Myung
Jae Kyung Myung
Kihean KimKihean Kim
Kihean Kim
Ionizing radiation (IR) injury is tissue damage caused by high energy electromagnetic waves such as X-ray and gamma ray. Diagnosis and treatment of IR injury are difficult due to its characteristics of clinically latent post-irradiation periods and the following successive and unpredictable inflammatory bursts. Skin is one of the many sensitive organs to IR and bears local injury upon exposure. Early-stage diagnosis of IR skin injury is essential in order to maximize treatment efficiency and to prevent the aggravation of IR injury. In this study, early-stage changes of the IR injured skin at the cellular level were characterized in an in vivo mouse model by two-photon microscopy (TPM). Various IR doses were applied to the mouse hind limbs and the injured skin regions were imaged daily for 6 days after IR irradiation. Changes in the morphology and distribution of the epidermal cells and damage of the sebaceous glands were observed before clinical symptoms. These results showed that TPM is sensitive to early-stage changes of IR skin injury and may be useful for its diagnosis.

14 January 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
YYYeoreum Yoon
Yeoreum Yoon
WJWon Hyuk Jang
Won Hyuk Jang
Peng XiaoPeng Xiao
Peng Xiao
BKBumju Kim
Bumju Kim
TWTaejun Wang
Taejun Wang
KKKi Hean Kim
Ki Hean Kim
We report multimodal imaging of human oral cavity in vivo based on simultaneous wide-field reflectance/fluorescence imaging and polarization-sensitive optical coherence tomography (PS-OCT) with a forward-viewing imaging probe. Wide-field reflectance/fluorescence imaging and PS-OCT were to provide both morphological and fluorescence information on the surface, and structural and birefringent information below the surface respectively. The forward-viewing probe was designed to access the oral cavity through the mouth with dimensions of approximately 10 mm in diameter and 180 mm in length. The probe had field of view (FOV) of approximately 5.5 mm in diameter, and adjustable depth of field (DOF) from 2 mm to 10 mm by controlling numerical aperture (NA) in the detection path. This adjustable DOF was to accommodate both requirements for image-based guiding with high DOF and high-resolution, high-sensitivity imaging with low DOF. This multimodal imaging system was characterized by using a tissue phantom and a mouse model in vivo, and was applied to human oral cavity. Information of surface morphology and vasculature, and under-surface layered structure and birefringence of the oral cavity tissues was obtained. These results showed feasibility of this multimodal imaging system as a tool for studying oral cavity lesions in clinical applications.

21 September 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
WJWon Hyuk Jang
Won Hyuk Jang
APAreum Park
Areum Park
TWTaejun Wang
Taejun Wang
CKChan Johng Kim
Chan Johng Kim
HCHoonchul Chang
Hoonchul Chang
Kihean KimKihean Kim
Kihean Kim
Paneth cells are one of the principal epithelial cell types in the small intestine, located at the base of intestinal crypts. Paneth cells play key roles in intestinal host-microbe homeostasis via granule secretion, and their dysfunction is implicated in pathogenesis of several diseases including Crohn’s disease. Despite their physiological importance, study of Paneth cells has been hampered by the limited accessibility and lack of labeling methods. In this study, we developed a simple in vivo imaging method of Paneth cells in the intact mouse small intestine by using moxifloxacin and two-photon microscopy (TPM). Moxifloxacin, an FDA-approved antibiotic, was used for labeling cells and its fluorescence was strongly observed in Paneth cell granules by TPM. Moxifloxacin labeling of Paneth cell granules was confirmed by molecular counterstaining. Comparison of Paneth cells in wild type, genetically obese (ob/ob), and germ-free (GF) mice showed different granule distribution. Furthermore, Paneth cell degranulation was observed in vivo. Our study suggests that TPM with moxifloxacin labeling can serve as a useful tool for studying Paneth cell biology and related diseases.

9 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
VLViet-Hoan Le
Viet-Hoan Le
SLSeunghun Lee
Seunghun Lee
SLSeungwon Lee
Seungwon Lee
TWTaejun Wang
Taejun Wang
WJWon Hyuk Jang
Won Hyuk Jang
Kihean KimKihean Kim
Kihean Kim
Intravital microscopy of mouse calvarial bone marrow (BM) is a powerful method for studying hematopoietic stem cells (HSCs) and the BM microenvironment at the cellular level. However, the current method used to access the mouse calvaria allows for only a few imaging times in the same mouse because of scar formation and inflammation induced by multiple surgeries. Longitudinal imaging of the BM may help better understand its microenvironment. In this study, a mouse calvarial window model was developed for longitudinal imaging that involves attaching a cover glass window onto the mouse calvaria and sealing the surrounding exposed area with cyanoacrylate glue and dental cement. The model was used for the longitudinal two-photon microscopy (TPM) imaging of the BM engraftment process. The same BM cavity sites were imaged multiple times over 4 weeks after BM transplantation (BMT). Temporal changes in the BM microenvironment, such as the reconstitution of transplanted BM cells and the recovery of vasculature, were observed and analysed qualitatively and quantitatively. Longitudinal intravital microscopy using the mouse calvarial window model was successfully demonstrated and may be useful for further BM studies.

10 August 2021 in Optics Express
Verified
Journal Article
Open access
PDF file
JJJi Yong Joo
Ji Yong Joo
JLJun Ho Lee
Jun Ho Lee
WJWon Hyuk Jang
Won Hyuk Jang
YLYong Woon Lim
Yong Woon Lim
We propose a new method of through-focus scanning optical microscopy (TSOM) without a reference database, i.e., a model-less TSOM method. Building a TSOM reference database is time-consuming or even impractical in some TSOM applications that involve complex structures, such as 3D NAND, or irregular shapes such as defects. The proposed model-less TSOM method was used to determine just the height of defect particles, for the first time as far as we are aware. Defect height is the only relevant dimension for the display panel application. Specifically, we analyzed 40 organic light-emitting diode (OLED) surface defects using a lab-developed motion-free TSOM tool consisting of a 50× objective lens (numerical aperture (NA) 0.55), a 532-nm light source, an imaging detector with a 7.5-µm pitch, and a deformable mirror. The tool is in-line and capable of achieving high throughput non-destructively, both relevant features for industrial applications. We investigated linear regression relations between newly defined TSOM parameters (TSOM height, TSOM area and TSOM volume) and the defect heights, which were first measured by atomic force microscopy (AFM). Following defect classification based on in-focus images, we successfully found that the AFM height has a linear correlation with 50% TSOM height (H50%) within ± 20.3 nm (1σ) error over the range of 140 to 950 nm. The one-sigma error, i.e., 20.3 nm, was approximately λ/26 or 1/43 of the depth of focus (DOF) of the applied microscope.