Stephen F. Cauley

Stephen F. Cauley

Auto-generated profile, based on publicly available information

Stephen F. Cauley

Siemens Medical Solutions (B.C., W.-C.L., Z.H., S.F.C.), Boston, Massachusetts

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
MLM.G.F. Longo
M.G.F. Longo
JCJ. Conklin
J. Conklin
SCS.F. Cauley
S.F. Cauley
KSKawin Setsompop
Kawin Setsompop
QTQ. Tian
Q. Tian
SHS.Y. Huang
S.Y. Huang
BACKGROUND AND PURPOSE: Volumetric brain MR imaging typically has long acquisition times. We sought to evaluate an ultrafast MPRAGE sequence based on Wave-CAIPI (Wave-MPRAGE) compared with standard MPRAGE for evaluation of regional brain tissue volumes. MATERIALS AND METHODS: We performed scan-rescan experiments in 10 healthy volunteers to evaluate the intraindividual variability of the brain volumes measured using the standard and Wave-MPRAGE sequences. We then evaluated 43 consecutive patients undergoing brain MR imaging. Patients underwent 3T brain MR imaging, including a standard MPRAGE sequence (acceleration factor [R] = 2, acquisition time [TA] = 5.2 minutes) and an ultrafast Wave-MPRAGE sequence (R = 9, TA = 1.15 minutes for the 32-channel coil; R = 6, TA = 1.75 minutes for the 20-channel coil). Automated segmentation of regional brain volume was performed. Two radiologists evaluated regional brain atrophy using semiquantitative visual rating scales. RESULTS: The mean absolute symmetrized percent change in the healthy volunteers participating in the scan-rescan experiments was not statistically different in any brain region for both the standard and Wave-MPRAGE sequences. In the patients undergoing evaluation for neurodegenerative disease, the Dice coefficient of similarity between volumetric measurements obtained from standard and Wave-MPRAGE ranged from 0.86 to 0.95. Similarly, for all regions, the absolute symmetrized percent change for brain volume and cortical thickness showed <6% difference between the 2 sequences. In the semiquantitative visual comparison, the differences between the 2 radiologists’ scores were not clinically or statistically significant. CONCLUSIONS: Brain volumes estimated using ultrafast Wave-MPRAGE show low intraindividual variability and are comparable with those estimated using standard MPRAGE in patients undergoing clinical evaluation for suspected neurodegenerative disease.

14 November 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
JCJ. Conklin
J. Conklin
MLM.G.F. Longo
M.G.F. Longo
SCS.F. Cauley
S.F. Cauley
KSKawin Setsompop
Kawin Setsompop
RGRamon Gonzalez
Ramon Gonzalez
SHS.Y. Huang
S.Y. Huang
BACKGROUND AND PURPOSE: SWI is valuable for characterization of intracranial hemorrhage and mineralization but has long acquisition times. We compared a highly accelerated wave–controlled aliasing in parallel imaging (CAIPI) SWI sequence with 2 commonly used alternatives, standard SWI and T2*-weighted gradient recalled-echo (T2*W GRE), for routine clinical brain imaging at 3T. MATERIALS AND METHODS: A total of 246 consecutive adult patients were prospectively evaluated using a conventional SWI or T2*W GRE sequence and an optimized wave–CAIPI SWI sequence, which was 3–5 times faster than the standard sequence. Two blinded radiologists scored each sequence for the presence of hemorrhage, the number of microhemorrhages, and severity of motion artifacts. Wave–CAIPI SWI was then evaluated in head-to-head comparison with the conventional sequences for visualization of pathology, artifacts, and overall diagnostic quality. Forced-choice comparisons were used for all scores. Wave–CAIPI SWI was tested for superiority relative to T2*W GRE and for noninferiority relative to standard SWI using a 15% noninferiority margin. RESULTS: Compared with T2*W GRE, wave–CAIPI SWI detected hemorrhages in more cases (P < .001) and detected more microhemorrhages (P < .001). Wave–CAIPI SWI was superior to T2*W GRE for visualization of pathology, artifacts, and overall diagnostic quality (all P < .001). Compared with standard SWI, wave–CAIPI SWI showed no difference in the presence or number of hemorrhages identified. Wave–CAIPI SWI was noninferior to standard SWI for the visualization of pathology (P < .001), artifacts (P < .01), and overall diagnostic quality (P < .01). Motion was less severe with wave–CAIPI SWI than with standard SWI (P < .01). CONCLUSIONS: Wave–CAIPI SWI provided superior visualization of pathology and overall diagnostic quality compared with T2*W GRE and was noninferior to standard SWI with reduced scan times and reduced motion artifacts.

8 July 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
CNChanon Ngamsombat
Chanon Ngamsombat
AFA.L.M. Gonçalves Filho
A.L.M. Gonçalves Filho
MLM.G.F. Longo
M.G.F. Longo
SCS.F. Cauley
S.F. Cauley
KSKawin Setsompop
Kawin Setsompop
SHS.Y. Huang
S.Y. Huang
BACKGROUND AND PURPOSE: Our aim was to evaluate an ultrafast 3D-FLAIR sequence using Wave–controlled aliasing in parallel imaging encoding (Wave-FLAIR) compared with standard 3D-FLAIR in the visualization and volumetric estimation of cerebral white matter lesions in a clinical setting. MATERIALS AND METHODS: Forty-two consecutive patients underwent 3T brain MR imaging, including standard 3D-FLAIR (acceleration factor = 2, scan time = 7 minutes 50 seconds) and resolution-matched ultrafast Wave-FLAIR sequences (acceleration factor = 6, scan time = 2 minutes 45 seconds for the 20-channel coil; acceleration factor = 9, scan time = 1 minute 50 seconds for the 32-channel coil) as part of clinical evaluation for demyelinating disease. Automated segmentation of cerebral white matter lesions was performed using the Lesion Segmentation Tool in SPM. Student t tests, intraclass correlation coefficients, relative lesion volume difference, and Dice similarity coefficients were used to compare volumetric measurements among sequences. Two blinded neuroradiologists evaluated the visualization of white matter lesions, artifacts, and overall diagnostic quality using a predefined 5-point scale. RESULTS: Standard and Wave-FLAIR sequences showed excellent agreement of lesion volumes with an intraclass correlation coefficient of 0.99 and mean Dice similarity coefficient of 0.97 (SD, 0.05) (range, 0.84–0.99). Wave-FLAIR was noninferior to standard FLAIR for visualization of lesions and motion. The diagnostic quality for Wave-FLAIR was slightly greater than for standard FLAIR for infratentorial lesions (P < .001), and there were fewer pulsation artifacts on Wave-FLAIR compared with standard FLAIR (P < .001). CONCLUSIONS: Ultrafast Wave-FLAIR provides superior visualization of infratentorial lesions while preserving overall diagnostic quality and yields white matter lesion volumes comparable with those estimated using standard FLAIR. The availability of ultrafast Wave-FLAIR may facilitate the greater use of 3D-FLAIR sequences in the evaluation of patients with suspected demyelinating disease.

28 August 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
EMErica E Mason
Erica E Mason
EMEli Mattingly
Eli Mattingly
KHKonstantin Herb
Konstantin Herb
SCStephen F Cauley
Stephen F Cauley
MŚMonika Śliwiak
Monika Śliwiak
LWLawrence L Wald
Lawrence L Wald
Objective. Non-invasive functional brain imaging modalities are limited in number, each with its own complex trade-offs between sensitivity, spatial and temporal resolution, and the directness with which the measured signals reflect neuronal activation. Magnetic particle imaging (MPI) directly maps the cerebral blood volume (CBV), and its high sensitivity derives from the nonlinear magnetization of the superparamagnetic iron oxide nanoparticle (SPION) tracer confined to the blood pool. Our work evaluates functional MPI (fMPI) as a new hemodynamic functional imaging modality by mapping the CBV response in a rodent model where CBV is modulated by hypercapnic breathing manipulation. Approach. The rodent fMPI time-series data were acquired with a mechanically rotating field-free line MPI scanner capable of 5 s temporal resolution and 3 mm spatial resolution. The rat’s CBV was modulated for 30 min with alternating 5 min hyper-/hypocapnic states, and processed using conventional fMRI tools. We compare our results to fMRI responses undergoing similar hypercapnia protocols found in the literature, and reinforce this comparison in a study of one rat with 9.4T BOLD fMRI using the identical protocol. Main results. The initial image in the time-series showed mean resting brain voxel SNR values, averaged across rats, of 99.9 following the first 10 mg kg −1 SPION injection and 134 following the second. The time-series fit a conventional General Linear Model with a 15%–40% CBV change and a peak pixel CNR between 12 and 29, 2–6× higher than found in fMRI. Significance. This work introduces a functional modality with high sensitivity, although currently limited spatial and temporal resolution. With future clinical-scale development, a large increase in sensitivity could supplement other modalities and help transition functional brain imaging from a neuroscience tool focusing on population averages to a clinically relevant modality capable of detecting differences in individual patients.

26 January 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
Min LangMin Lang
Min Lang
Azadeh TabariAzadeh Tabari
Azadeh Tabari
DPD. Polak
D. Polak
JFJ. Ford
J. Ford
BCBryan Clifford
Bryan Clifford
SHS.Y. Huang
S.Y. Huang
BACKGROUND AND PURPOSE: A scout accelerated motion estimation and reduction (SAMER) framework has been developed for efficient retrospective motion correction. The goal of this study was to perform an initial evaluation of SAMER in a series of clinical brain MR imaging examinations. MATERIALS AND METHODS: Ninety-seven patients who underwent MR imaging in the inpatient and emergency department settings were included in the study. SAMER motion correction was retrospectively applied to an accelerated T1-weighted MPRAGE sequence that was included in brain MR imaging examinations performed with and without contrast. Two blinded neuroradiologists graded images with and without SAMER motion correction on a 5-tier motion severity scale (none = 1, minimal = 2, mild = 3, moderate = 4, severe = 5). RESULTS: The median SAMER reconstruction time was 1 minute 47 seconds. SAMER motion correction significantly improved overall motion grades across all examinations (P < .005). Motion artifacts were reduced in 28% of cases, unchanged in 64% of cases, and increased in 8% of cases. SAMER improved motion grades in 100% of moderate motion cases and 75% of severe motion cases. Sixty-nine percent of nondiagnostic motion cases (grades 4 and 5) were considered diagnostic after SAMER motion correction. For cases with minimal or no motion, SAMER had negligible impact on the overall motion grade. For cases with mild, moderate, and severe motion, SAMER improved the motion grade by an average of 0.3 (SD, 0.5), 1.1 (SD, 0.3), and 1.1 (SD, 0.8) grades, respectively. CONCLUSIONS: SAMER improved the diagnostic image quality of clinical brain MR imaging examinations with motion artifacts. The improvement was most pronounced for cases with moderate or severe motion.

7 March 2024 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
Min LangMin Lang
Min Lang
BCBryan Clifford
Bryan Clifford
WLWei-Ching Lo
Wei-Ching Lo
BABrooks P. Applewhite
Brooks P. Applewhite
ATAzadeh Tabari
Azadeh Tabari
JCJohn Conklin
John Conklin
BACKGROUND AND PURPOSE: The use of MR imaging in emergency settings has been limited by availability, long scan times, and sensitivity to motion. This study assessed the diagnostic performance of an ultrafast brain MR imaging protocol for evaluation of acute intracranial pathology in the emergency department and inpatient settings. MATERIALS AND METHODS: Sixty-six adult patients who underwent brain MR imaging in the emergency department and inpatient settings were included in the study. All patients underwent both the reference and the ultrafast brain MR protocols. Both brain MR imaging protocols consisted of T1-weighted, T2/T2*-weighted, FLAIR, and DWI sequences. The ultrafast MR images were reconstructed by using a machine-learning assisted framework. All images were reviewed by 2 blinded neuroradiologists. RESULTS: The average acquisition time was 2.1 minutes for the ultrafast brain MR protocol and 10 minutes for the reference brain MR protocol. There was 98.5% agreement on the main clinical diagnosis between the 2 protocols. In head-to-head comparison, the reference protocol was preferred in terms of image noise and geometric distortion (P < .05 for both). The ultrafast ms-EPI protocol was preferred over the reference protocol in terms of reduced motion artifacts (P < .01). Overall diagnostic quality was not significantly different between the 2 protocols (P > .05). CONCLUSIONS: The ultrafast brain MR imaging protocol provides high accuracy for evaluating acute pathology while only requiring a fraction of the scan time. Although there was greater image noise and geometric distortion on the ultrafast brain MR protocol images, there was significant reduction in motion artifacts with similar overall diagnostic quality between the 2 protocols.