Florian Ströhl

Florian Ströhl

Auto-generated profile, based on publicly available information

Florian Ströhl

Department of Physics and Technology, UiT The Arctic University of Norway, Tromsø, Norway

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
JLJanin Lautenschläger
Janin Lautenschläger
ASAmberley D Stephens
Amberley D Stephens
GFGiuliana Fusco
Giuliana Fusco
FSFlorian Ströhl
Florian Ströhl
NCNathan Curry
Nathan Curry
GSGabriele S. Kaminski Schierle
Gabriele S. Kaminski Schierle
Alpha-synuclein is known to bind to small unilamellar vesicles (SUVs) via its N terminus, which forms an amphipathic alpha-helix upon membrane interaction. Here we show that calcium binds to the C terminus of alpha-synuclein, therewith increasing its lipid-binding capacity. Using CEST-NMR, we reveal that alpha-synuclein interacts with isolated synaptic vesicles with two regions, the N terminus, already known from studies on SUVs, and additionally via its C terminus, which is regulated by the binding of calcium. Indeed, dSTORM on synaptosomes shows that calcium mediates the localization of alpha-synuclein at the pre-synaptic terminal, and an imbalance in calcium or alpha-synuclein can cause synaptic vesicle clustering, as seen ex vivo and in vitro. This study provides a new view on the binding of alpha-synuclein to synaptic vesicles, which might also affect our understanding of synucleinopathies.

4 April 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CRChristopher J. Rowlands
Christopher J. Rowlands
FSFlorian Ströhl
Florian Ströhl
PRPedro P. Vallejo Ramirez
Pedro P. Vallejo Ramirez
KSKatharina M. Scherer
Katharina M. Scherer
CKClemens F. Kaminski
Clemens F. Kaminski
Super-resolution single-molecule localization microscopy, often referred to as PALM/STORM, works by ensuring that fewer than one fluorophore in a diffraction-limited volume is emitting at any one time, allowing the observer to infer that the emitter is located at the center of the point-spread function. This requires careful control over the incident light intensity in order to control the rate at which fluorophores are switched on; if too many fluorophores are activated, their point-spread functions overlap, which impedes efficient localization. If too few are activated, the imaging time is impractically long. There is therefore considerable recent interest in constructing so-called ‘top-hat’ illumination profiles that provide a uniform illumination over the whole field of view. We present the use of a single commercially-available low-cost refractive beamshaping element that can be retrofitted to almost any existing microscope; the illumination profile created by this element demonstrates a marked improvement in the power efficiency of dSTORM microscopy, as well as a significant reduction in the propensity for reconstruction artifacts, compared to conventional Gaussian illumination.

20 March 2020 in Biomedical Optics Express
Verified
Journal Article
Open access
JMJames D. Manton
James D. Manton
FSFlorian Stroehl
Florian Stroehl
RFReto Fiolka
Reto Fiolka
CKClemens F. Kaminski
Clemens F. Kaminski
EREric J. Rees
Eric J. Rees
Wide-field fluorescence microscopy, while much faster than confocal microscopy, suffers from a lack of optical sectioning and poor axial resolution. 3D structured illumination microscopy (SIM) has been demonstrated to provide optical sectioning and to double the resolution limit both laterally and axially, but even with this the axial resolution is still worse than the lateral resolution of unmodified wide-field microscopy. Interferometric schemes using two high numerical aperture objectives, such as 4Pi confocal and I5M microscopy, have improved the axial resolution beyond that of the lateral, but at the cost of a significantly more complex optical setup. Here, we theoretically and numerically investigate a simpler dual-objective scheme which we propose can be easily added to an existing 3D-SIM microscope, providing lateral and axial resolutions in excess of 125 nm with conventional fluorophores and without the need for interferometric detection.

22 August 2019 in Optics Express
Verified
Journal Article
Open access
PDF file
FSFlorian Ströhl
Florian Ströhl
IOIda Sundvor Opstad
Ida Sundvor Opstad
JTJean-Claude Tinguely
Jean-Claude Tinguely
FDFirehun T. Dullo
Firehun T. Dullo
IMIoanna Mela
Ioanna Mela
CKClemens F. Kaminski
Clemens F. Kaminski
Labelfree nanoscopy encompasses optical imaging with resolution in the 100 nm range using visible wavelengths. Here, we present a labelfree nanoscopy method that combines coherent imaging techniques with waveguide microscopy to realize a super-condenser featuring maximally inclined coherent darkfield illumination with artificially stretched wave vectors due to large refractive indices of the employed Si3N4 waveguide material. We produce the required coherent plane wave illumination for Fourier ptychography over imaging areas 400 μm2 in size via adiabatically tapered single-mode waveguides and tackle the overlap constraints of the Fourier ptychography phase retrieval algorithm two-fold: firstly, the directionality of the illumination wave vector is changed sequentially via a multiplexed input structure of the waveguide chip layout and secondly, the wave vector modulus is shortend via step-wise increases of the illumination light wavelength over the visible spectrum. We test the method in simulations and in experiments and provide details on the underlying image formation theory as well as the reconstruction algorithm. While the generated Fourier ptychography reconstructions are found to be prone to image artefacts, an alternative coherent imaging method, rotating coherent scattering microscopy (ROCS), is found to be more robust against artefacts but with less achievable resolution.

23 March 2022 in Scientific Data
Verified
Journal Article
Open access
PDF file
IOIda Sundvor Opstad
Ida Sundvor Opstad
GGGustav Godtliebsen
Gustav Godtliebsen
FSFlorian Ströhl
Florian Ströhl
TMTruls MYRMEL
Truls MYRMEL
BABalpreet Singh Ahluwalia
Balpreet Singh Ahluwalia
ÅBÅsa Birna Birgisdottir
Åsa Birna Birgisdottir
This three-dimensional structured illumination microscopy (3DSIM) dataset was generated to highlight the suitability of 3DSIM to investigate mitochondria-derived vesicles (MDVs) in H9c2 cardiomyoblasts in living or fixed cells. MDVs act as a mitochondria quality control mechanism. The cells were stably expressing the tandem-tag eGFP-mCherry-OMP25-TM (outer mitochondrial membrane) which can be used as a sensor for acidity. A part of the dataset is showing correlative imaging of lysosomes labeled using LysoTracker in fixed and living cells. The cells were cultivated in either normal or glucose-deprived medium containing galactose. The resulting 3DSIM data were of high quality and can be used to undertake a variety of studies. Interestingly, many dynamic tubules derived from mitochondria are visible in the 3DSIM videos under both glucose and galactose-adapted growth conditions. As the raw 3DSIM data, optical parameters, and reconstructed 3DSIM images are provided, the data is especially suitable for use in the development of SIM reconstruction algorithms, bioimage analysis methods, and for biological studies of mitochondria.

17 February 2020 in Journal of Biophotonics
Verified
Journal Article
Open access
PDF file
IOIda Sundvor Opstad
Ida Sundvor Opstad
FSFlorian Ströhl
Florian Ströhl
MFMarcus Fantham
Marcus Fantham
CHColin Hockings
Colin Hockings
OVOliver Vanderpoorten
Oliver Vanderpoorten
CKClemens F. Kaminski
Clemens F. Kaminski
Large fields of view (FOVs) in total internal reflection fluorescence microscopy (TIRFM) via waveguides have been shown to be highly beneficial for single molecule localisation microscopy on fixed cells [1,2] and have also been demonstrated for short‐term live‐imaging of robust cell types [3‐5], but not yet for delicate primary neurons nor over extended periods of time. Here, we present a waveguide‐based TIRFM set‐up for live‐cell imaging of demanding samples. Using the developed microscope, referred to as the ChipScope, we demonstrate successful culturing and imaging of fibroblasts, primary rat hippocampal neurons and axons of Xenopus retinal ganglion cells (RGCs). The high contrast and gentle illumination mode provided by TIRFM coupled with the exceptionally large excitation areas and superior illumination homogeneity offered by photonic waveguides have potential for a wide application span in neuroscience applications.