28 December 2016 in PLOS ONE
CGCanadian Critical Care Trials Group
Canadian Critical Care Trials Group
+11
The objective of this study was to assess the safety and feasibility of in-bed cycling started within the first 4 days of mechanical ventilation (MV) to inform a future randomized clinical trial. We conducted a 33-patient prospective cohort study in a 21-bed adult academic medical-surgical intensive care unit (ICU) in Hamilton, ON, Canada. We included adult patients (≥ 18 years) receiving MV who walked independently pre-ICU. Our intervention was 30 minutes of in-bed supine cycling 6 days/week in the ICU. Our primary outcome was Safety (termination), measured as events prompting cycling termination; secondary Safety (disconnection or dislodgement) outcomes included catheter/tube dislodgements. Feasibility was measured as consent rate and fidelity to intervention. For our primary outcome, we calculated the binary proportion and 95% confidence interval (CI). From 10/2013-8/2014, we obtained consent from 34 of 37 patients approached (91.9%), 33 of whom received in-bed cycling. Of those who cycled, 16(48.4%) were female, the mean (SD) age was 65.8(12.2) years, and APACHE II score was 24.3(6.7); 29(87.9%) had medical admitting diagnoses. Cycling termination was infrequent (2.0%, 95% CI: 0.8%-4.9%) and no device dislodgements occurred. Cycling began a median [IQR] of 3 [2, 4] days after ICU admission; patients received 5 [3, 8] cycling sessions with a median duration of 30.7 [21.6, 30.8] minutes per session. During 205 total cycling sessions, patients were receiving invasive MV (150 [73.1%]), vasopressors (6 [2.9%]), sedative or analgesic infusions (77 [37.6%]) and dialysis (4 [2.0%]). Early cycling within the first 4 days of MV among hemodynamically stable patients is safe and feasible. Research to evaluate the effect of early cycling on patient function is warranted. Clinicaltrials.gov: NCT01885442
2 November 2021 in Respiratory Care
Providing supplemental oxygen to hospitalized adults is a frequent practice and can be administered via a variety of devices. Oxygen therapy has evolved over the years, and clinicians should follow evidence-based practices to provide maximum benefit and avoid harm. This systematic review and subsequent clinical practice guidelines were developed to answer questions about oxygenation targets, monitoring, early initiation of high-flow oxygen (HFO), benefits of HFO compared to conventional oxygen therapy, and humidification of supplemental oxygen. Using a modification of the RAND/UCLA Appropriateness Method, 7 recommendations were developed to guide the delivery of supplemental oxygen to hospitalized adults: (1) aim for range of 94–98% for most hospitalized patients (88–92% for those with COPD), (2) the same range of 94–98% for critically ill patients, (3) promote early initiation of HFO, (4) consider HFO to avoid escalation to noninvasive ventilation, (5) consider HFO immediately postextubation to avoid re-intubation, (6) either HFO or conventional oxygen therapy may be used with patients who are immunocompromised, and (7) consider humidification for supplemental oxygen when flows > 4 L/min are used.
15 February 2021 in Critical Care
Background: Reverse triggering (RT) is a dyssynchrony defined by a respiratory muscle contraction following a passive mechanical insufflation. It is potentially harmful for the lung and the diaphragm, but its detection is challenging. Magnitude of effort generated by RT is currently unknown. Our objective was to validate supervised methods for automatic detection of RT using only airway pressure (Paw) and flow. A secondary objective was to describe the magnitude of the efforts generated during RT. Methods: We developed algorithms for detection of RT using Paw and flow waveforms. Experts having Paw, flow and esophageal pressure (Pes) assessed automatic detection accuracy by comparison against visual assessment. Muscular pressure (Pmus) was measured from Pes during RT, triggered breaths and ineffective efforts. Results: Tracings from 20 hypoxemic patients were used (mean age 65 ± 12 years, 65% male, ICU survival 75%). RT was present in 24% of the breaths ranging from 0 (patients paralyzed or in pressure support ventilation) to 93.3%. Automatic detection accuracy was 95.5%: sensitivity 83.1%, specificity 99.4%, positive predictive value 97.6%, negative predictive value 95.0% and kappa index of 0.87. Pmus of RT ranged from 1.3 to 36.8 cmH20, with a median of 8.7 cmH20. RT with breath stacking had the highest levels of Pmus, and RTs with no breath stacking were of similar magnitude than pressure support breaths. Conclusion: An automated detection tool using airway pressure and flow can diagnose reverse triggering with excellent accuracy. RT generates a median Pmus of 9 cmH2O with important variability between and within patients. Trial registration: BEARDS, NCT03447288.
1 June 2019 in Respiratory Care
For more than 40 years, noninvasive ventilation has been the first-line preferred therapy for acute-on-chronic conditions, such as COPD and cardiogenic pulmonary edema. The use of noninvasive ventilation in the treatment of hypoxemic respiratory failure, however, has been met with mixed results associated with higher risks of intubation (failure of therapy) and with higher risks of mortality. The purpose of this review was to describe the current evidence and important considerations when patients with hypoxemic respiratory failure are managed with noninvasive ventilation.
24 May 2022 in Respiratory Care
Electrical impedance tomography is no longer a new technology, but its clinical use at the bedside is still in its primary stage. Global research has drastically increased since its commercial availability, and this has slowly begun to make its way into routine clinical bedside use in some areas of the world. This paper will provide the bedside clinician an introduction to the technology, how it is used, and the most common applications found in the literature.
1 June 2020 in Respiratory Care
Lung volume measurement performed during invasive mechanical ventilation can be used to determine functional residual capacity, changes in end-expiratory lung volume with the application of PEEP, and lung strain. However, many bedside measurements provide useful information without the use of specialized equipment. Ventilation distribution through the lung has traditionally been assessed with computed tomography, but more recently electrical impedance tomography has brought the ability to monitor this at the bedside, and without exposure to radiation. This review will describe techniques to measure lung volumes in the ICU and the relationship between lung strain, stress, and other measurements. This review will also discuss monitoring ventilation distribution at the bedside and the clinical assessment of regional compliance that this technology provides.