Richard N. Southard

Richard N. Southard

Auto-generated profile, based on publicly available information

Richard N. Southard

From the Department of Radiology, Phoenix Children’s Hospital, 1919 E Thomas Rd, Main Tower, Phoenix, AZ 85016 (C.L.S., M.C.P., R.N.S., L.G., D.R.B.); Department of Radiology, Mayo Clinic, Phoenix, Ariz (L.K.H.); Department of Radiology, UT Health San Antonio, San Antonio, Tex (V.S.K.); and Baylor College of Medicine, Houston, Tex (E.T.).

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2019 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
RSR N Southard
R N Southard
DBD.M.E. Bardo
D.M.E. Bardo
MTM.H. Temkit
M.H. Temkit
MTM.A. Thorkelson
M.A. Thorkelson
RAR.A. Augustyn
R.A. Augustyn
CMC.A. Martinot
C.A. Martinot
BACKGROUND AND PURPOSE: Noncontrast CT of the head is the initial imaging test for traumatic brain injury, stroke, or suspected nonaccidental trauma. Low-dose head CT protocols using filtered back-projection are susceptible to increased noise and decreased image quality. Iterative reconstruction noise suppression allows the use of lower-dose techniques with maintained image quality. We review our experience with children undergoing emergency head CT examinations reconstructed using knowledge-based iterative model reconstruction versus standard filtered back-projection, comparing reconstruction times, radiation dose, and objective and subjective image quality. MATERIALS AND METHODS: This was a retrospective study comparing 173 children scanned using standard age-based noncontrast head CT protocols reconstructed with filtered back-projection with 190 children scanned using low-dose protocols reconstructed with iterative model reconstruction. ROIs placed on the frontal white matter and thalamus yielded signal-to-noise and contrast-to-noise ratios. Volume CT dose index and study reconstruction times were recorded. Random subgroups of patients were selected for subjective image-quality review. RESULTS: The volume CT dose index was significantly reduced in studies reconstructed with iterative model reconstruction compared with filtered back-projection, (mean, 24.4 ± 3.1 mGy versus 31.1 ± 6.0 mGy, P < .001), while the SNR and contrast-to-noise ratios improved 2-fold (P < .001). Radiologists graded iterative model reconstruction images as superior to filtered back-projection images for gray-white matter differentiation and anatomic detail (P < .001). The average reconstruction time of the filtered back-projection studies was 101 seconds, and with iterative model reconstruction, it was 147 seconds (P < .001), without a practical effect on work flow. CONCLUSIONS: In children referred for emergency noncontrast head CT, optimized low-dose protocols with iterative model reconstruction allowed us to significantly reduce the relative dose, on average, 22% compared with filtered back-projection, with significantly improved objective and subjective image quality.

1 March 2024 in RadioGraphics
Verified
Journal Article
Closed access
CSCurtis L. Simmons
Curtis L. Simmons
LHLaura K. Harper
Laura K. Harper
MPMittun C. Patel
Mittun C. Patel
VKVenkat S. Katabathina
Venkat S. Katabathina
RSRichard N. Southard
Richard N. Southard
DBDeepa R. Biyyam
Deepa R. Biyyam
Biliary abnormalities in children are uncommon, and the spectrum of biliary disorders is broader than in adult patients. Unlike in adults, biliary disorders in children are rarely neoplastic and are more commonly rhabdomyosarcoma rather than cholangiocarcinoma. Pediatric biliary disorders may be embryologic or congenital, such as anatomic gallbladder anomalies, anomalous pancreaticobiliary tracts, various cholestatic processes, congenital cystic lesions, or genetic conditions. They may also be benign, such as biliary filling anomalies, biliary motility disorders, and biliary inflammatory and infectious disorders. Distinguishing these entities with a single imaging modality is challenging. US is the primary imaging modality for initial evaluation of biliary abnormalities in children, due to its wide availability, lack of ionizing radiation, and low cost and because it requires no sedation. Other examinations such as MRI, CT, and nuclear medicine examinations may provide anatomic and functional information to narrow the diagnosis further. Hepatobiliary-specific contrast material with MRI can provide better assessment of biliary anatomy on delayed images than can traditional MRI contrast material. MR cholangiopancreatography (MRCP) allows visualization of the intra- and extrahepatic biliary ducts, which may not be possible with endoscopic retrograde cholangiopancreatography (ERCP). Suspected biliary atresia requires multiple modalities for diagnosis and timely treatment. Determining the type of choledochal cyst calls for a combination of initial US and MRCP. Many benign and malignant biliary masses require biopsy for definitive diagnosis. Knowledge of the imaging appearances of different pediatric biliary abnormalities is necessary for appropriate imaging workup, providing a diagnosis or differential diagnosis, and guiding appropriate management. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.