9 March 2018 in IEEE Transactions on Magnetics
Traditionally, flux distributions in transformer cores are modeled as a 2-D problem. However, experimental studies indicate that 3-D models are needed. The main reason is that limbs of circular cross section are combined with roughly semi-circular yokes. At the joints, this yields shifts of overlap regions as a reason of significant (off-plane) normal direction (ND) induction BND. This paper reports a first corresponding 3-D modeling of a two-package one-phase core with the consideration of non-linear characteristics of material. For corners, the so-called critical induction BCRIT of joints--as arising close to 1.4 T--is considered. Two instants of the cycle of global magnetization are addressed, i.e., BGL = 1.7 T for normal operation and 1.9 T as a value that may arise for dc bias. For 1.7 T, the results indicate strong inhomogeneity, in particular in the wide main package of the core. On the other hand, 1.9 T is characterized by distinct homogenization. As 3-D effects, the cycle of magnetization involves distinct changes of flux in ND, with values up to more than 0.2 T. Half-cycle saturation is indicated especially for inner (window-sided) corner regions. The corresponding consequences on local magnetostriction (MS) values are over-proportional due to the complex dependence of strain λ and induction. The so-called butterfly curve is dynamically passed beyond the turn point and even into its positive range. In particular, this yields distinct distortion of λ , which can be assumed as a source of over-proportional rises of A-weighted noise. Apart from MS, further enhancement is to be expected from inter-laminar forces.
22 September 2020 in IEEE Transactions on Magnetics
Magnetic energy losses of SiFe sheets are determined by the standardized methods of single sheet tester (SST) or Epstein tester (ET). According to IEC standards, the total power consumption is measured in Watt-metric ways, and the portion that concerns the homogeneously magnetized region(s) is estimated on a nominal value l m of the so-called conventional effective magnetic path length (PL). A clear definition of PL is lacking-a suggestion being provided here. Standards express l m through the dependence between the magnetic field strength H and the magnetization current. However, they apply the same value l m also for the determination of losses P. From the viewpoint of physics, two PL quantities l m,H and l m,P would be preferable. The problematic is enhanced by the fact that the flux distribution within the magnetic circuit of a tester may change dynamically during the period of time, with induction changes B(t). This means that the physical PL L is a function of time, according to a PL function L[B(t)]. Finally, dynamic changes in flux distributions prove to be distinctly influenced by hysteretic mechanisms which means that L[B(t)] exhibits loop character. The resulting complexity indicates that the concept of PL is not promising, if high accuracy of testing is demanded. However, for purposes of material comparisons, optimum PL values LOPT may be suitable that are determined for individual material families. Analyses of instantaneous loss power values p(t) indicate that energy dissipation is weak during high induction. Thus, determinations of LOPT should be focussed on moderate induction. The ET is characterized by strong modifications of 3-D flux distributions which means that individual values LOPT would be needed. On the other hand, the SST shows a clear design. For moderate induction, some energy dissipation is expected to occur within the yoke region. This indicates that LOPT exceeds the conventional value of 450 mm, in weak ways.
10 July 2007 in Sensors and Actuators A: Physical
23 June 2020 in IEEE Transactions on Magnetics
Magnetic energy losses of SiFe sheets are determined by the standardized methods of Single Sheet Tester (SST) or Epstein Tester (ET). The ET is much more compact and can be applied in a large range of frequency. However, it suffers from several sources of systematic errors. The most severe one is given by the magnetic cores flux distribution that shows a strong degree of inhomogeneity. This fact is highly evident. However, it never has been investigated in detail so far. Here we report results of a 3D modelling, performed by Magnetic Anisotropic Circuit Calculation (MACC), considering non-linearity in connection with anisotropy, for both non-oriented (NO) steel and grain oriented (GO) steel. The results reveal substantial differences of the corresponding flux distributions. NO steel proves to be characterized by high homogeneity of induction in rolling direction in the middle sections of the four limbs. However, the four corners show strong inhomogeneity in instants of low global induction, while a transition to more balanced flux arises at peak magnetization. On the other hand, this transition is much less pronounced for GO steel. As a conclusion for the evaluation of losses, a distinction is needed for the two different types of material.
1 October 2022 in AIP Advances
For decades, much effort has been made to establish test systems for the determination of magnetic losses of electric steels. However, presently available systems are still associated with considerable deficiencies. Meanwhile, increased awareness of preservation of energy enforces the need to determine losses with absolute accuracy. Furthermore, modern drives yield demand for multi-frequency testing. This paper summarizes a multi-frequency test system that avoids the major physical compromises of conventional methodologies. The paper describes the overall design of “physically consistent magnetic loss testing” (CLT) with preferred sample size of 500 × 170 mm2. Specific emphasis is placed on four crucial features: (i) Practical independency of sample state from an extra-thin yoke. (ii) Effective field detection with consideration of demagnetizing field components. (iii) Effective induction detection with advanced air flux compensation, based on true-field conditions. (iv) Complete suppression of harmonics for unique results. Results for time-averaged losses and for instantaneous power functions of grain-oriented steels are presented for frequencies ranging from 162/3 Hz to 10 kHz. For thermal and practical reasons, loss determination is restricted to a maximum of 100 W/kg. The design of CLT claims to be the first loss test concept with an assessed absolute accuracy of about 2.5%. Considering the benefits of the presented system, the method is proposed as a base for international standardization.
1 May 2024 in AIP Advances
Measurements of magnetic losses of electric steel are usually performed by International Electrotechnical Commission standardized Epstein testers or Single Sheet Testers (SSTs). According to round robin tests, the corresponding levels of repeatability are of the order of 0.1%, and those of reproducibility are of the order of 1%. However, orders of absolute accuracy are unknown due to the applied “current method.” Here, we report corresponding tests for the so-called “physically consistent SST.” Consistency is achieved by a “giant” tangential field coil on a 50 cm long and 17 cm wide soft magnetic sample, using a thin amorphous yoke for magnetization. Tests were made in two labs with very different working conditions (sea levels of 200 and 1100 m, respectively), with very similarly built-up testers. Measurements were made for peak inductions between 1 and 1.9 T. For two distributed samples, the repeatability errors were lower than 0.3%, and the reproducibility errors were lower than 1%. This indicates that SSTs with an H-coil are not less reliable than current based ones. However, the absolute accuracy can be estimated to be much better, being close to 2%.