18 August 2020 in Optics Letters
Noninvasive, objective measurement of rod function is as significant as that of cone function, and for retinal diseases such as retinitis pigmentosa and age-related macular degeneration, rod function may be a more sensitive biomarker of disease progression and efficacy of treatment than cone function. Functional imaging of single human rod photoreceptors, however, has proven difficult because their small size and rapid functional response pose challenges for the resolution and speed of the imaging system. Here, we describe light-evoked, functional responses of human rods and cones, measured noninvasively using a synchronized adaptive optics optical coherence tomography (OCT) and scanning light ophthalmoscopy (SLO) system. The higher lateral resolution of the SLO images made it possible to confirm the identity of rods in the corresponding OCT volumes.
22 September 2022 in Optica
Optoretinography (ORG) is an emerging tool for testing neural function in the retina. Unlike existing methods, it is noninvasive and objective, and provides information about retinal structure and function at once. As such, it has great potential to transform ophthalmic care and clinical trials of novel therapeutics designed to restore or preserve visual function. Recent efforts have demonstrated the feasibility of ORG using state-of-the-art optical coherence tomography systems. These methods measure the stimulus-evoked movement of subcellular features in the retina, using the phase of reflected light to monitor their positions. Here we present an alternative approach that monitors the velocity of these features instead. This conceptual shift has significant implications for the nascent field of ORG. By avoiding the need to track specific cells over time, it obviates costly and laborious aspects of position-based approaches, such as adaptive optics, digital aberration correction, real-time tracking, and three-dimensional segmentation and registration. We used this velocity-based approach to measure the photoreceptor ORG responses in three healthy subjects. The resulting responses were reproducible and exhibited dependence on dose and retinal eccentricity. The possibility of reconstructing the position signal through numerical integration of velocity was explored.
30 September 2020 in Biomedical Optics Express
A retinal imaging system was designed for full-field (FF) swept-source (SS) optical coherence tomography (OCT) with cellular resolution. The system incorporates a real-time adaptive optics (AO) subsystem and a very high-speed CMOS sensor, and is capable of acquiring volumetric images of the retina at rates up to 1 kHz. While digital aberration correction (DAC) is an attractive potential alternative to AO, it has not yet been shown to provide resolution allowing visualization of cones in the fovea, where early detection of functional deficits is most critical. Here we demonstrate that FF-SS-OCT with hardware AO permits resolution of foveal cones, imaged at eccentricities of 1° and 2°, with volume rates adequate to measure light-evoked changes in photoreceptors. With the reference arm blocked, the system can operate as a kilohertz AO flood illumination fundus camera with adjustable temporal coherence and is expected to allow measurement of light-evoked changes caused by common path interference in photoreceptor outer segments (OS). In this paper, we describe the system’s optical design, characterize its performance, and demonstrate its ability to produce images of the human photoreceptor mosaic.
12 August 2024 in Optics Letters
A full-field swept-source optical coherence tomography (FF-SS-OCT) for in vivo murine retinal imaging is demonstrated. The on-axis FF-SS-OCT system was built in a Mach–Zehnder interferometer configuration employing a tunable laser source with an adjustable sweep rate and sweep range in conjunction with a fast 2D-CMOS camera. A large field retinal (coherent) illumination was accomplished using an imaging interface comprised of a short-focal length imaging lens and a contact lens. The magnification between the camera and retina (spatial sampling) was appropriately chosen to record the microscopic structural features of the retina in the image. A pupil stop was employed in the detection path to reject unwanted backscattering from the mouse eye and other sources and limit aberrations distorting the retinal images. In vivo mouse retinal imaging was performed at a sweep rate of 150 Hz to acquire volumes unaffected by the system vibrations, which predominated at lower frequencies. Operating the FF-SS-OCT at this speed yielded an effective axial scan rate of 20 million A-scans/s and a field of view of 820 × 410 µm (24.12° × 12.06°). High-quality retinal B-scans and enface images of the retina were obtained with the SS-FF-OCT, revealing all major retinal layers and vascular plexuses.
1 October 2017 in Journal of Vision
The integrated Stiles-Crawford function is commonly used as apodization model for vision through the natural eye pupil. However, this method does not account for possible effects related to the retinal thickness, the large length-to-diameter aspect ratio of the photoreceptors, or the use of nonMaxwellian illumination. Here, we introduce a geometrical optics model to calculate the fraction of overlap between light at the retina and the photoreceptor outer segments where absorption triggers vision. The model, which does not account for photoreceptor waveguiding, is discussed for both Maxwellian and nonMaxwellian illumination. The integrated Stiles-Crawford effect is analyzed experimentally with a uniaxial pupil-size flicker methodology and we find that the psychophysical measurements match better to the geometrical optics predictions than direct integration of a Stiles-Crawford function.
8 December 2015 in Optica
The reduction of wavefront aberrations is essential in a number of fields, including astronomy, microscopy, photography, vision science, lithography, and lasers. Aberrations may be determined either directly with wavefront sensors or indirectly with signal- or image-based optimization algorithms. Here, we introduce a novel wavefront-sensing methodology that employs intensity differences across a beam of light to encode local wavefront slopes via attenuated total internal reflection following surface-plasmon excitation at the surface of a thin gold film. This method excels due to the dense spatial sampling of the wavefront and the fact that the wavefront itself can be determined by straightforward integration of two sets of images captured in orthogonal directions without time-consuming optimization, deconvolution, or spot centroiding.