Richard Thomas Wood

Richard Thomas Wood

Auto-generated profile, based on publicly available information

Richard Thomas Wood

The University of Tennessee

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
RWRichard T. Wood
Richard T. Wood
BUBelle R. Upadhyaya
Belle R. Upadhyaya
DFDan C. Floyd
Dan C. Floyd
Several Generation IV nuclear reactor concepts have goals for optimizing investment recovery through phased introduction of multiple units on a common site with shared facilities and/or reconfigurable energy conversion systems. Additionally, small modular reactors are suitable for remote deployment to support highly localized microgrids in isolated, underdeveloped regions. The long-term economic viability of these advanced reactor plants depends on significant reductions in plant operations and maintenance costs. To accomplish these goals, intelligent control and diagnostic capabilities are needed to provide nearly autonomous operations with anticipatory maintenance. A nearly autonomous control system should enable automatic operation of a nuclear power plant while adapting to equipment faults and other upsets. It needs to have many intelligent capabilities, such as diagnosis, simulation, analysis, planning, reconfigurability, self-validation, and decision. These capabilities have been the subject of research for many years, but an autonomous control system for nuclear power generation remains as-yet an unrealized goal. This article describes a functional framework for intelligent, autonomous control that can facilitate the integration of control, diagnostic, and decision-making capabilities to satisfy the operational and performance goals of power plants based on multimodular advanced reactors

30 March 2018 in Nuclear Technology
Verified
Journal Article
Closed access
EEEzell Ezell
Ezell Ezell
CBChuck Britton
Chuck Britton
NENance Ericson
Nance Ericson
DHDavid Holcomb
David Holcomb
MRM. J. Roberts
M. J. Roberts
RWRichard Wood
Richard Wood
Johnson noise thermometry is one of many important measurement techniques used to monitor the safety levels and stability in a nuclear reactor. However, this measurement is very dependent on the minimal electromagnetic environment. Properly removing unwanted electromagnetic interference (EMI) is critical for accurate drift-free temperature measurements. The two techniques developed by Oak Ridge National Laboratory (ORNL) to remove transient and periodic EMI are briefly discussed in this paper. Spectral estimation is a key component in the signal processing algorithm used for EMI removal and temperature calculation. The cross-power spectral density is a key component in the Johnson noise temperature computation. Applying either technique requires the simple addition of electronics and signal processing to existing resistive thermometers. With minimal installation changes, the system discussed here can be installed on existing nuclear power plants. The Johnson noise system developed is tested at three locations: ORNL, Sandia National Laboratory, and the Tennessee Valley Authority’s Kingston Fossil Plant. Each of these locations enabled improvement on the EMI removal algorithm. The conclusions made from the results at each of these locations is discussed, as well as possible future work.

1 July 1986 in Nuclear Technology
Verified
Journal Article
Closed access
JMJose March-Leuba
Jose March-Leuba
RWRichard T. Wood
Richard T. Wood
POPedro J. Otaduy
Pedro J. Otaduy
CMClayton O. McNew
Clayton O. McNew
The results of neutronic stability tests performed on February 9, 1985, at the Browns Ferry Nuclear Power Plant Unit 1 under single-loop operation (SLO) conditions are documented. The main conclusions of the tests are as follows: 1. The observed increase in neutron noise during SLO is solely due to an increase in flow noise. 2. The Browns Ferry-1 reactor has been found to be stable in all modes of operation attained during the current tests. The most unstable test point corresponded to minimum recirculation pump speed in SLO. This operating condition has the minimum flow and maximum power-to-flow ratio. At this operating point, the estimated decay ratio of the neutron flux following an impulse perturbation of reactivity was 0.53. 3. The decay ratio decreased as the flow was increased during SLO. This observation implies that corewide reactor stability follows the same trends in single-loop as it does in two-loop operation. 4. Finally, no local instabilities were found in the data taken from local power range monitors. Decay ratios estimated from the local power range monitors were not significantly different from those estimated from the average power range monitors.

1 January 2011 in Nuclear Technology
Verified
Journal Article
Closed access
RWRichard Wood
Richard Wood
(2011). Foreword: Special Issue on the Sixth International Topical Meeting on Nuclear Plant Instrumentation, Control, and Human-Machine Interface Technologies. Nuclear Technology: Vol. 173, No. 1, pp. 1-1. doi: 10.13182/NT11-A11477

1 March 2006 in Nuclear Technology
Verified
Journal Article
Closed access
KZKe Zhao
Ke Zhao
BUBelle R. Upadhyaya
Belle R. Upadhyaya
RWRichard T. Wood
Richard T. Wood
A design approach to sensor fault detection and isolation (FDI) of helical coil steam generator (HCSG) systems of the International Reactor Innovation Secure (IRIS) reactor is presented. In the design phase, a physical model is first developed to provide a realistic simulation and generate data characterizing the system dynamics. A subspace identification technique is then used to extract a low-order linear state-space model from the data. Finally, a robust dynamic parity space approach is utilized to design residual generators for FDI. This design approach is able to achieve fault isolation following a predetermined logic without the need to use data during fault conditions, which is an unrealistic assumption of many FDI approaches studied for nuclear power plants. The results of the HCSG application show that the approach is robust to not only measurement and process noises but also operation condition changes and has the capability of correct FDI during reactor power transients and during the propagation of sensor faults in a control loop.

1 January 2002
Verified
Book Chapter
Closed access
PDF file
RWRichard T. Wood
Richard T. Wood