Harsimrat Kaur

Harsimrat Kaur

Auto-generated profile, based on publicly available information

Harsimrat Kaur

Faculty of Medicine and Dentistry University of Alberta Edmonton Alberta Canada

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2019 in Orthodontics & Craniofacial Research
Verified
Journal Article
Open access
PDF file
LRLindsay Robertson
Lindsay Robertson
HKHarsimrat Kaur
Harsimrat Kaur
NFNathalia Carolina Fernandes Fagundes
Nathalia Carolina Fernandes Fagundes
DRDan Romanyk
Dan Romanyk
PMPaul Major
Paul Major
CFCarlos Flores-Mir
Carlos Flores-Mir
Objective: To analyse through a systematic review the effectiveness of clear aligners by assessing: (a) predictability of clear aligners and (b) treatment outcome comparison of clear aligner therapy with fixed appliance therapy.Methods: An electronic search was made from January 2014 to April 2019 using MEDLINE, Embase, Web of Science and LILACS databases without any limitations on language. Three reviewers independently assessed the articles. Quality assessment of observational studies and randomized control trial was done by using the ROBINS tool and Cochrane risk of bias tool, respectively. GRADE instrument was used to assess certainty level for each identified outcome.Results: Seven eligible articles (one randomized controlled trial and six retrospective cohort) were included in our systematic review. Most of the studies (six out of seven) had a moderate risk of bias and one had a high risk of bias.Conclusions: ‘Low to moderate level’ of certainty in regard to specific clear aligner therapy tooth movements’ efficiency was identified. Clear aligners may produce clinically acceptable outcomes that could be comparable to fixed appliance therapy for buccolingual inclination of upper and lower incisors in mild to moderate malocclusions. However, not all potential clinical scenarios have been assessed in the included studies. Most of the tooth movements may not be predictable enough to be accomplished with only one set of trays with clear aligners despite the recent advances in technology.

1 September 2021 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
HKHarsimrat Kaur
Harsimrat Kaur
JTJason Truong
Jason Truong
GHGiseon Heo
Giseon Heo
JMJames K. Mah
James K. Mah
PMPaul W. Major
Paul W. Major
DRDan L. Romanyk
Dan L. Romanyk

10 August 2022 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
HKHarsimrat Kaur
Harsimrat Kaur
TKTsolmonbaatar Khurelbaatar
Tsolmonbaatar Khurelbaatar
JMJames Mah
James Mah
GHGiseon Heo
Giseon Heo
PMPaul W. Major
Paul W. Major
DRDan L. Romanyk
Dan L. Romanyk

6 February 2025 in Orthodontics & Craniofacial Research
Verified
Journal Article
Open access
HKHarsimrat Kaur
Harsimrat Kaur
ASArya Subramanian
Arya Subramanian
JMJames Mah
James Mah
GHGiseon Heo
Giseon Heo
PMPaul W. Major
Paul W. Major
DRDan L. Romanyk
Dan L. Romanyk
The objective of the presented study was to evaluate the biomechanics of aligners utilising attachments and the effect of their placement for extrusion. An in vitro Orthodontic SIMulator (OSIM) was used to measure forces and moments produced through aligners incorporating attachments. The maxillary teeth on OSIM were digitally scanned to generate an STL model that was modified by placing a rectangular shaped attachment. Four models were designed with variation in attachment placement: Model NA—no attachment; model BA—buccal attachment; model LA—lingual attachment; model BL—both buccal and lingual attachments. Aligners (n = 30/model) were fabricated using a 0.75 mm thick polyethylene terephthalate material using a Biostar machine following the manufacturer's recommendations. A one‐way MANOVA, followed by one‐way ANOVA was used to test the effect of models on occlusogingival force (Fz) and mesiodistal moment (Mx) at 0.20 mm of gingival displacement of the left lateral incisor. The BL model exerted maximum Fz (1.22 ± 0.20 N), followed by models BA (1.18 ± 0.25 N) and LA (1.07 ± 0.19 N). The model NA exerted a negligible Fz (0.14 ± 0.08 N) that was statistically different from all other models. The models BA and LA generated Mx that has the tendency to tip the crown of tooth lingually (10.00 ± 3.12 Nmm) and buccally (−1.29 ± 2.26 Nmm), respectively. The models show statistically significant differences between models BL, BA and LA. There was no statistically significant difference between models BL and NA. The experimental evidence suggest that attachments on the lateral incisor could improve the predictability of extrusion forces applied with aligners. The models BL and LA provided favourable biomechanics by generating clinically significant extrusion forces without significant tipping of the lateral incisor tooth.

1 February 2024 in Orthodontics & Craniofacial Research
Verified
Journal Article
Open access
HKHarsimrat Kaur
Harsimrat Kaur
TKTsolmonbaatar Khurelbaatar
Tsolmonbaatar Khurelbaatar
JMJames Mah
James Mah
GHGiseon Heo
Giseon Heo
PMPaul W. Major
Paul W. Major
DRDan L. Romanyk
Dan L. Romanyk
IntroductionTo evaluate biomechanics of an aligner utilizing divots and the effect of their vertical placement on the right maxillary central incisor.MethodsAn in vitro Orthodontic SIMulator (OSIM) was used to test forces and moments generated by aligners incorporating divots. The OSIM arch was scanned to generate a. STL version that was modified to create four models by placing divots on different positions of the right central maxillary incisor: GI - divots on gingival-third of lingual surface and incisal-third of labial surface; GM - divots on gingival-third of lingual surface and middle-third of labial surface; MI - divots on middle-third of lingual surface and incisal-third of labial surface; MM - divots on middle-third of lingual surface and middle-third of labial surface. Aligners (n = 30/model) were fabricated using a 0.75 mm thick polyethylene terephthalate material and Biostar (R) machine following the manufacturer's recommendations. A one-way MANOVA followed by one-way ANOVA (alpha = 0.05) was utilized to test effect of models on buccolingual force (Fy) and mesiodistal moment (Mx) at 0.20 mm of lingual displacement of the right maxillary central incisor.ResultsMean Mx for GI (-5.68 +/- 7.38 Nmm), GM (3.75 +/- 5.54 Nmm), MI (-4.27 +/- 1.48 Nmm) and MM (1.96 +/- 0.99 Nmm) models showed statistical differences between GI and GM, GI and MM, GM and MI and MI and MM. GI exerted the largest Fy (1.87 +/- 0.75 N) followed by GM (1.10 +/- 0.47 N), MI (0.70 +/- 0.23 N) and MM (0.28 +/- 0.08 N) with significant differences between GI and GM, GI and MI, GI and MM and GM and MM models.ConclusionsVertical divot placement on a right central incisor had a significant effect on aligner biomechanics. Buccolingual forces exerted by models GI, GM and MI were within the range suggested by literature for bodily tooth movement without major root tipping for GM and MI models.